Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Cont Coil Volt 110 Vac Aux Cont 4 No+ 4 Nc
|
| Description |
|
| Organisation | Department of Heavy Industry | Ministry of Heavy Industries and Public Enterprises |
| Tender Id | GEM/2025/B/6086696 |
|
Reference Number |
- |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link |
View Original Tender Notice
https://bidplus.gem.gov.in/all-bids |
| Start Date | March 25, 2025 21:20 |
| End Date |
Expired
04/04/2025
Expired 558 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Award of Contract & Bid Results
REGENCY ELECTRICALS PRIVATE LIMITED.
273614.4
Technical Evaluation Results
| S.No. | Seller Name | Offered Item | Participated On | MSE/MII Status | Status |
|---|---|---|---|---|---|
| 1 | MOHAN EXIM INDIA PRIVATE LIMITED | Make : Siemens Model : 3RH2122-1BF408K+3RH2911-1HA22 Title : CONT COIL VOLT 110VAC AUX CONT 4NO+ 4NC | 07-04-2025 11:50:28 | MII | Qualified |
| 2 | REGENCY ELECTRICALS PRIVATE LIMITED. | Make : SIEMENS Model : 3RH2122-1AF00-8K+3RH2911-1HA22 Title : CONT COIL VOLT 110VAC AUX CONT 4NO+ 4NC | 07-04-2025 16:03:06 | MII | Qualified |
Financial Evaluation Results
| S.No. | Seller Name | Offered Item | Total Price | Rank |
|---|---|---|---|---|
| 1 | REGENCY ELECTRICALS PRIVATE LIMITED.(MII) | Item Categories : CONT COIL VOLT 110VAC AUX CONT 4NO+ 4NC | 231876.61 | L1 |
| 2 | MOHAN EXIM INDIA PRIVATE LIMITED (MII) | Item Categories : CONT COIL VOLT 110VAC AUX CONT 4NO+ 4NC | 317633.90 | L2 |
Ordered Items & Contract Pricing
| Product | Brand | Model | Ordered Quantity | Price |
|---|---|---|---|---|
| CONT COIL VOLT 110VAC AUX CONT 4NO+ 4NC | SIEMENS | 3RH2122-1AF00-8K+3RH2911-1HA22 | 240 | ₹ 273614.400 |
Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Read moreAuxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Auxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Read moreAngle gauge for tool grinding standard,anvil 50 kg - with stand,blow lamp 1 liter capacity,bunsen burners,digital lux meter lcd read out 0.05 to 7000 lumens with battery.,drill angle gauge 45 degree,60 degree,90 degree,dual dc regulated power supply 30-0-30 v, 2 amps,earth copper plate 60cm x 60cm x 3.15 mm,hot wire ammeter 0-15 amps.,lcr meter digital handheld,lead acid battery- 12v 100 ah,lead acid battery- 12v 40 ah,lead acid battery- 12v 75 ah,magnetic flux meter 0-500 tesla,magnifying glass 75 mm with magnifying factor 10x,manual motor coil winding machine,pipe vice cast iron with hardened jaw open type 100 mm,precision angle grinding vice 200 mm,rheostat 0-25 ohms 1 amp,rheostat 0-300 ohms 2 amp,side and face cutter dia 80 x 10 x dia 27 mm,slitting saw cutter dia 75 x 4 x dia 27 mm,soldering and de soldering station,stands with clamps for burette,sterilizer,sun shine recorder,taps and s complete 5, 6, 8, 10 and 12mm of 5,temperature controlled soldering iron 50 watt, 230 volt,temperature gaug
Angle gauge for tool grinding standard,anvil 50 kg - with stand,blow lamp 1 liter capacity,bunsen burners,digital lux meter lcd read out 0.05 to 7000 lumens with battery.,drill angle gauge 45 degree,60 degree,90 degree,dual dc regulated power supply 30-0-30 v, 2 amps,earth copper plate 60cm x 60cm x 3.15 mm,hot wire ammeter 0-15 amps.,lcr meter digital handheld,lead acid battery- 12v 100 ah,lead acid battery- 12v 40 ah,lead acid battery- 12v 75 ah,magnetic flux meter 0-500 tesla,magnifying glass 75 mm with magnifying factor 10x,manual motor coil winding machine,pipe vice cast iron with hardened jaw open type 100 mm,precision angle grinding vice 200 mm,rheostat 0-25 ohms 1 amp,rheostat 0-300 ohms 2 amp,side and face cutter dia 80 x 10 x dia 27 mm,slitting saw cutter dia 75 x 4 x dia 27 mm,soldering and de soldering station,stands with clamps for burette,sterilizer,sun shine recorder,taps and s complete 5, 6, 8, 10 and 12mm of 5,temperature controlled soldering iron 50 watt, 230 volt,temperature gaug
Read moreProcurement of contactor volt 110vac aux cont 4no 4nc
Procurement of contactor volt 110vac aux cont 4no 4nc