Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Repairing And Fitting Of Safety Device Electronic Relay Fitted For 3.3 Kv And 400 Amp Ocb Switch At Bhowra South Colliery For Two No Of Switch.
|
| Description |
Repairing And Fitting Of Safety Device Electronic Relay Fitted For 3.3 Kv And 400 Amp Ocb Switch At Bhowra South Colliery For Two No Of Switch.
|
| Organisation | Coal India Limited (CIL) |
| Tender Id | 2023_BCCL_284353_1 |
|
Reference Number |
BCCL/EJA/ENM/E Tender/2023-24/53 |
| Tender Fee | - |
| EMD | 5526 |
| Tender Value | - |
| Place | E. J. Area, Bhowra |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in |
| Start Date | July 26, 2023 20:30 |
| End Date |
Expired
11/08/2023
Expired 1160 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
For repairing of incomer 400a,6.6kv, ocb switch sl.no. bsp/switch/06 make ferguson at ekra substation basdeopur colliery under sijua area
For repairing of incomer 400a,6.6kv, ocb switch sl.no. bsp/switch/06 make ferguson at ekra substation basdeopur colliery under sijua area
Read moreHand drill machine 600w 230v 1 point 5 13mm 2800rpm,tester tong 0 to 1000a 660v,3.3kv 400amps fwd off rev isolator part no htsv0003,master trip relay 110v dc cspc86 part no 1907739,puller bearing hyd 10ton,contactor main 550v 300 by 400a,tester hv detector 0 to 11kv for flp switch
Hand drill machine 600w 230v 1 point 5 13mm 2800rpm,tester tong 0 to 1000a 660v,3.3kv 400amps fwd off rev isolator part no htsv0003,master trip relay 110v dc cspc86 part no 1907739,puller bearing hyd 10ton,contactor main 550v 300 by 400a,tester hv detector 0 to 11kv for flp switch
Read morePrimary current injection set,pvc pipe bending machine,multifunction meter,bldc motor with controller,servo motor with resolver,pmsm with controller,mppt based charge controller,digital timer,impulse relay,dusk and dawn switch,twisted pair non metallic sheathed cable underground feeder cable ribbon cable metallic sheathed cable multi conductor cable coaxial cable direct buried cable optical fiber cable,starter motor axial type,starter motor pre engagement type,starter motor co axial type,meter reading instrument mri,various electronic components resistors diode transistor ujt fet scr diac traic igbt small transformer,dmx controller,rewinding machine,multi scan tool,capacitors electrolytic ceramic polyester film variable dual run
Primary current injection set,pvc pipe bending machine,multifunction meter,bldc motor with controller,servo motor with resolver,pmsm with controller,mppt based charge controller,digital timer,impulse relay,dusk and dawn switch,twisted pair non metallic sheathed cable underground feeder cable ribbon cable metallic sheathed cable multi conductor cable coaxial cable direct buried cable optical fiber cable,starter motor axial type,starter motor pre engagement type,starter motor co axial type,meter reading instrument mri,various electronic components resistors diode transistor ujt fet scr diac traic igbt small transformer,dmx controller,rewinding machine,multi scan tool,capacitors electrolytic ceramic polyester film variable dual run
Read moreVcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Read moreCalibration and repair of moisture meter,test cup,spur gear,bevel gear,guide nut,insulation disk,thrust bearing,bevel pinion,micro controller,electronic switch,com. pcb,com. meggar box,temperature sensor,i.c. regulator 7805,timer i.c. 7555,i.c 4051,i.c 7447,eprom,f.n.d. board,ic 7135,complete body universal,bracket,spur pinion bigsmall,40 pin header set,pinion brush,lead screw,volume cup a,volume cup b,volume cup c,allen key,battery compartment,adaptor,connector leads 12 pin,connector leads 2 3 pins,relay,segment i.c.,i.c. 7600,switching transistor bc 107,crystal 6.144 mhz,ic base 16 pins,ic base 28 pins,ic 7600,dry cell 1.5 nv,at mega 328 p set,lcd 16x2,duvcon mager complete sticker,22 ohm,printer i.c.,module cell for date and time,ic base 20 pin,complete power supply,scale screw,carrier handle,body universal without spare,rachet handle,max 232,pressure plate,ic 74373,spur gear axle,wooden box big small,body dmm,plunger agro,crank handle agro,top plunger,bottom plunger,circular scale,bk handle test cup,pcb l
Calibration and repair of moisture meter,test cup,spur gear,bevel gear,guide nut,insulation disk,thrust bearing,bevel pinion,micro controller,electronic switch,com. pcb,com. meggar box,temperature sensor,i.c. regulator 7805,timer i.c. 7555,i.c 4051,i.c 7447,eprom,f.n.d. board,ic 7135,complete body universal,bracket,spur pinion bigsmall,40 pin header set,pinion brush,lead screw,volume cup a,volume cup b,volume cup c,allen key,battery compartment,adaptor,connector leads 12 pin,connector leads 2 3 pins,relay,segment i.c.,i.c. 7600,switching transistor bc 107,crystal 6.144 mhz,ic base 16 pins,ic base 28 pins,ic 7600,dry cell 1.5 nv,at mega 328 p set,lcd 16x2,duvcon mager complete sticker,22 ohm,printer i.c.,module cell for date and time,ic base 20 pin,complete power supply,scale screw,carrier handle,body universal without spare,rachet handle,max 232,pressure plate,ic 74373,spur gear axle,wooden box big small,body dmm,plunger agro,crank handle agro,top plunger,bottom plunger,circular scale,bk handle test cup,pcb l
Read moreRepairing and fitting of safety device electronic relay fitted for 3.3kv 400 amp. ocb switch at bhowra south colliery
Repairing and fitting of safety device electronic relay fitted for 3.3kv 400 amp. ocb switch at bhowra south colliery
Read moreRepairing and fitting of safety device electronic relay,p.t. fitted for 11kv, 400amps ocb switch
Repairing and fitting of safety device electronic relay,p.t. fitted for 11kv, 400amps ocb switch for compliance of violation given by dgms at 4a patch substation bhowra south colliery.
Read moreRepairing and reconditioning of one no. 11kv 400amp. vcb and one no. 3.3kv 400amp ocb switch of kuju colliery under kuju area
Repairing and reconditioning of one no. 11kv 400amp. vcb and one no. 3.3kv 400amp ocb switch of kuju colliery under kuju area
Read moreProviding and fitting of safety device relay fitted for 3.3 kv 400 amp. ocb switch two nos. at bhowra north ug mines under eja
Providing and fitting of safety device relay fitted for 3.3 kv 400 amp. ocb switch two nos. at bhowra north ug mines under eja
Read moreInstallation and commissioning of negative sequence relay in 11kv 400amp. ocb make crompton greaves of 4a patch substation of bhowra south colliery.
Installation and commissioning of negative sequence relay in 11kv 400amp. ocb make crompton greaves of 4a patch substation of bhowra south colliery.
Read moreof your Industry type