Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Prive/Predicative And Over Hauling Of 33 Kv Indoor And Outdoor Breaker (Panel) Both Side. Without Door 33 Kv Grade C.T Opening And Re Connection Of Tripping System Of Transformer 10 Mva, 33 Kv/11 Kv Grade At South Loyabad Sub Station Under Kusunda
|
| Description |
Prive/Predicative And Over Hauling Of 33 Kv Indoor And Outdoor Breaker (Panel) Both Side. Without Door 33 Kv Grade C.T Opening And Re Connection Of Tripping System Of Transformer 10 Mva, 33 Kv/11 Kv Grade At South Loyabad Sub Station Under Kusunda
|
| Organisation | Bharat Coking Coal Limited | Public Sector Undertakings |
| Tender Id | 2025_BCCL_343103_1 |
|
Reference Number |
BCCL/AVI/EnM/2025-26/62 |
| Tender Fee | 0 |
| EMD | 2100 |
| Tender Value | |
| Place | Kusunda Area |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=355665 |
| Start Date | September 04, 2025 16:30 |
| End Date |
Expired
16/09/2025
Expired 289 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Preventive/predicative of 33kv tie-line feeder including dismantling and re fitting of 33kv grade c.t at outdoor yard sub-station r/k under katras area....
Preventive/predicative of 33kv tie-line feeder including dismantling and re fitting of 33kv grade c.t at outdoor yard sub-station r/k under katras area....
Read moreDismantling ,heightening with re-installation of c.t 33kv grade primary side of abb breaker(control of 3.15mva power transformer 33kv/11kv) for safety point of view n commissioning, testing of new installed breaker( 05 nos 3.3kv n 03 nos 11kv)
Dismantling ,heightening with re-installation of c.t 33kv grade primary side of abb breaker(control of 3.15mva power transformer 33kv/11kv) for safety point of view n commissioning, testing of new installed breaker( 05 nos 3.3kv n 03 nos 11kv)
Read moreDismantling of 2 core ct, supply and installation of 3 core new ct at 11 kv vcb switch of incomer -01 of transformer no 01 (33kv/11kv 10 mva) for connection of deferential relay at south loyabad sub-station under kusunda area.
Dismantling of 2 core ct, supply and installation of 3 core new ct at 11 kv vcb switch of incomer -01 of transformer no 01 (33kv/11kv 10 mva) for connection of deferential relay at south loyabad sub-station under kusunda area.
Read moreFor installation of two nos percentage differential relay in 33kv panel of transformer 1 and 2 and dismantling, installation of 33 kv ct at 33 kv side of transformer no 1 and 2 at (33kv/11kv, 10mva) south loyabad sub-station under kusunda area
For installation of two nos percentage differential relay in 33kv panel of transformer 1 and 2 and dismantling, installation of 33 kv ct at 33 kv side of transformer no 1 and 2 at (33kv/11kv, 10mva) south loyabad sub-station under kusunda area
Read moreDismantling of 2 core ct, supply and installation of 3 core new ct at 11 kv vcb switch of incomer -02 of transformer no.02 (33kv/11kv, 10mva) for connection of deferential relay at south loyabad sub-station under kusunda area.
Dismantling of 2 core ct, supply and installation of 3 core new ct at 11 kv vcb switch of incomer -02 of transformer no.02 (33kv/11kv, 10mva) for connection of deferential relay at south loyabad sub-station under kusunda area.
Read moreComplete installation, testing and commissioning of vacuum circuit breaker 33 kv grade, 33kv control panel with ct and pt, 2 mva transformer, 33 kv/ 3.3kv, 3.3 kv indoor vcb panels at main sub-station of amadand ug mine
Complete installation, testing and commissioning of vacuum circuit breaker 33 kv grade, 33kv control panel with ct and pt, 2 mva transformer, 33 kv/ 3.3kv, 3.3 kv indoor vcb panels at main sub-station of amadand ug mine
Read moreRefurbishment of 2 nos of control panel 33kv ,1250 amps grade for control of 2 nos sf6 circuit breaker for control and protection of two nos 10 mva transformer feeding power to akkocp and bokaro ocp at 33kv main substation under akkocp, bnk area
Refurbishment of 2 nos of control panel 33kv ,1250 amps grade for control of 2 nos sf6 circuit breaker for control and protection of two nos 10 mva transformer feeding power to akkocp and bokaro ocp at 33kv main substation under akkocp, bnk area
Read moreComplete installation ,testing and commissioning of vacuum circuit breaker 33 kv grade ,33 kv control panel with ct and pt ,3 mva transformer ,33 kv/6.6 kv , 6.6 kv indoor vcb panels at main sub-station of baroud ocm .
Complete installation ,testing and commissioning of vacuum circuit breaker 33 kv grade ,33 kv control panel with ct and pt ,3 mva transformer ,33 kv/6.6 kv , 6.6 kv indoor vcb panels at main sub-station of baroud ocm .