| Title |
Dismantling ,Heightening With Re Installation Of C.T 33 Kv Grade Primary Side Of Abb Breaker(control Of 3.15 Mva Power Transformer 33 Kv/11 Kv) For Safety Point Of View N Commissioning, Testing Of New Installed Breaker( 05 Nos 3.3 Kv N 03 Nos 11 Kv)
|
| Description |
Dismantling ,Heightening With Re Installation Of C.T 33 Kv Grade Primary Side Of Abb Breaker(control Of 3.15 Mva Power Transformer 33 Kv/11 Kv) For Safety Point Of View N Commissioning, Testing Of New Installed Breaker( 05 Nos 3.3 Kv N 03 Nos 11 Kv)
|
| Organisation | Coal India Limited (CIL) |
| Tender Id | 2023_CCL_284803_5 |
|
Reference Number |
SO(EnM)/e-tender/23-24/09 |
| Tender Fee | |
| EMD | 6300 |
| Tender Value | |
| Place | GM Office, BnK Area |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in |
| Start Date | August 03, 2023 16:30 |
| End Date |
Expired
12/08/2023
Expired 1054 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Repairing/maintenance of 02 nos. control panel (1) primary control of 33/3.3kv, 5mva mirzapur transformer breaker control panel make abb (2) primary control of marson transformer breaker control panel installed at mrss of bnk area
Repairing/maintenance of 02 nos. control panel (1) primary control of 33/3.3kv, 5mva mirzapur transformer breaker control panel make abb (2) primary control of marson transformer breaker control panel installed at mrss of bnk area
Read moreRepair and maintenance of control cables along with re-commissioning, testing of installed breakers (33kv 8 no, 11kv 7 no, 3.3kv- 10 no), dismantling n laying of ht xlpe armored power cable 11 n 3.3kv grade) upto 120 sq.mm and power control c
Repair and maintenance of control cables along with re-commissioning, testing of installed breakers (33kv 8 no, 11kv 7 no, 3.3kv- 10 no), dismantling n laying of ht xlpe armored power cable 11 n 3.3kv grade) upto 120 sq.mm and power control c
Read morePrive/predicative and over- hauling of 33kv indoor and outdoor breaker (panel) both side. without door 33kv grade c.t opening and re-connection of tripping system of transformer 10 mva, 33kv/11kv grade at south loyabad sub- station under kusunda
Prive/predicative and over- hauling of 33kv indoor and outdoor breaker (panel) both side. without door 33kv grade c.t opening and re-connection of tripping system of transformer 10 mva, 33kv/11kv grade at south loyabad sub- station under kusunda
Read moreRepairing of 15 nos of instrumental transformers, 33kv grade for primary control ,metering and protection of 33kv grade transformer installed at mrss, bnk area.
Repairing of 15 nos of instrumental transformers, 33kv grade for primary control ,metering and protection of 33kv grade transformer installed at mrss, bnk area.
Read moreRepairing of 15 nos of instrumental transformers, 33kv grade for primary control ,metering and protection of 33kv grade transformer installed at mrss, bnk area
Repairing of 15 nos of instrumental transformers, 33kv grade for primary control ,metering and protection of 33kv grade transformer installed at mrss, bnk area
Read moreInstallation and commissioning of 3 nos of vacuum circuit breaker 2 nos of 3.3kv 400 amp grade control of mines feeder and one no of 11kv grade for control of feeder 2 to be installed at 33kv substation akkocp under bnk area.
Installation and commissioning of 3 nos of vacuum circuit breaker 2 nos of 3.3kv 400 amp grade control of mines feeder and one no of 11kv grade for control of feeder 2 to be installed at 33kv substation akkocp under bnk area.
Read moreRepairing of 3.3kv 400amp ocb switch controlling to 2000 kva power transformer as secondary switch installed at view point 11kv sub station.
Repairing of 3.3kv 400amp ocb switch controlling to 2000 kva power transformer as secondary switch installed at view point 11kv sub station.
Read moreRepair and maintenance of 3 nos 3.3 kv grade circuit breaker installed as primary control of transformer at different colonies under kargali ocp.
Repair and maintenance of 3 nos 3.3 kv grade circuit breaker installed as primary control of transformer at different colonies under kargali ocp.
Read morePrive maintenance n repairing of 30 nos of 33kv grade current transformers (400/200-5-5) and potential transformer 33000v/110v for primary control of different transformers installed at 33kv main sub-station mrss
Prive maintenance n repairing of 30 nos of 33kv grade current transformers (400/200-5-5) and potential transformer 33000v/110v for primary control of different transformers installed at 33kv main sub-station mrss
Read moreDismantling of 3mva, 11kv/3.3kv and re-installation of 3mva, 11kv/3.3kv, power transformer with repairing of one no. vcb at zero point sub-station of gvp ph-ii ocp.
Dismantling of 3mva, 11kv/3.3kv and re-installation of 3mva, 11kv/3.3kv, power transformer with repairing of one no. vcb at zero point sub-station of gvp ph-ii ocp.
 