Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Complete Frp Housing As Per Drg No. Ic [Complete Frp Housing As Per Drg No. Icf/Std 5 4 005, Alt. N Item No. 14,16,17,20 & 21 In Assembled Condition. Note Assembly Shall Be Suitably Packed So As To Glass Of Housing Will Be Safe.]
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106531810 |
|
Reference Number |
68242175A |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Jabalpur |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/112024/106531810/viewNitPdf_4780743.pdf |
| Start Date | November 21, 2024 18:49 |
| End Date |
Expired
29/11/2024
Expired 689 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Brushless dc railway carriage fan 225 mm sweep 110v dc bracket type complete as per rdso specification no. rdso/pe/spec/tl/0021-2005 rev.3 with amendment no. 1 with frp blade and crash worth guard. the guard shall be conforming to drg. no. icf/sk-7-6-158 coi-ii alt.g od of the fan guard 270mm plus minus 2 mm. dimension of fan shall conform to drawing rdso/pe/sk/tl/0026-2002 (rev 0 ) and complete fan will be silver ash colour
Brushless dc railway carriage fan 225 mm sweep 110v dc bracket type complete as per rdso specification no. rdso/pe/spec/tl/0021-2005 rev.3 with amendment no. 1 with frp blade and crash worth guard. the guard shall be conforming to drg. no. icf/sk-7-6-158 coi-ii alt.g od of the fan guard 270mm plus minus 2 mm. dimension of fan shall conform to drawing rdso/pe/sk/tl/0026-2002 (rev 0 ) and complete fan will be silver ash colour
Read moreRepair, maintenance, and installation of plant/ systems/equipments (version 2) - hospital medical equipment and devices consumables shall be provided by the service provider and will be reimbursed as per the approved rate list
Repair, maintenance, and installation of plant/ systems/equipments (version 2) - hospital medical equipment and devices consumables shall be provided by the service provider and will be reimbursed as per the approved rate list
Read moreGrill for non- ac emergency openable window, to drawing/specification icf drg. no. icf/std-5-4-005, alt-n, item no - 3,5,6,7,8,9,10 & 11 in assembled condition material & spec. as per drawing.
Grill for non- ac emergency openable window, to drawing/specification icf drg. no. icf/std-5-4-005, alt-n, item no - 3,5,6,7,8,9,10 & 11 in assembled condition material & spec. as per drawing.
Read moreEarthing cable complete for wheel set earthing equipment to bogie [for lhb type coaches] to rcf drg. no. lw71249, alt. (c), all items in assembled condition.
Earthing cable complete for wheel set earthing equipment to bogie [for lhb type coaches] to rcf drg. no. lw71249, alt. (c), all items in assembled condition.
Read moreArc box complete for tap changer of memu conforming to bhel drg no. 05801330003v00 or balaji enterprises drg no. be/tapc/sg/13be26. suitable for fitment in memu motor coach.
Arc box complete for tap changer of memu conforming to bhel drg no. 05801330003v00 or balaji enterprises drg no. be/tapc/sg/13be26. suitable for fitment in memu motor coach.
Read moreSupply, installation and commissioning of siv testing panel (100 kva oil cooled transformer) as per attached specification. note: the siv testing panel shall be suitable for testing, checking and performance verification of 180 kva / 2x130kva static inverters (sivs) used in wag-7 electric locomotives.the panel shall be capable of simulating operating conditions and conducting functional, load and protection tests of siv units. the firm shall supply, install and commission the complete siv test
Supply, installation and commissioning of siv testing panel (100 kva oil cooled transformer) as per attached specification. note: the siv testing panel shall be suitable for testing, checking and performance verification of 180 kva / 2x130kva static inverters (sivs) used in wag-7 electric locomotives.the panel shall be capable of simulating operating conditions and conducting functional, load and protection tests of siv units. the firm shall supply, install and commission the complete siv test
Read moreLateral damper for secondary air spring suspension arrangement to icf drg. no. dc/emu/m/asr-0-5-005 alt-p/6, item no. 2 and guarantee/warranty shall be as per clause-8 of rdso spec. no. c-8703 rev.3, of april 2023. and spec rdso spec no. :c-8703 rev.3, of april 2023.
Lateral damper for secondary air spring suspension arrangement to icf drg. no. dc/emu/m/asr-0-5-005 alt-p/6, item no. 2 and guarantee/warranty shall be as per clause-8 of rdso spec. no. c-8703 rev.3, of april 2023. and spec rdso spec no. :c-8703 rev.3, of april 2023.
Read moreSingle piece frp louvre shutter (2 -0 wide window) for lhb non-ac coaches to rcf drg. no. ls54102 alt-nil ,mat & spec. as per rdso spec.no. rdso/2007/cg-02 (rev-1) of feb, 2008 with 3 amendments- last amendment slip no.3 of february 2019, colour of material shall be light grey.
Single piece frp louvre shutter (2 -0 wide window) for lhb non-ac coaches to rcf drg. no. ls54102 alt-nil ,mat & spec. as per rdso spec.no. rdso/2007/cg-02 (rev-1) of feb, 2008 with 3 amendments- last amendment slip no.3 of february 2019, colour of material shall be light grey.
Read morePot assy. complete 200 ohms, 25w forfoot throttle confirming to hillgraham part no. : f119 or equival,1k, 25w pot assembled with spindlelock for active field loss reference. pot should be of imp origine,hand throttle assy complete with dual gang pots each of 1 k ohm, 25w rating (ohmite) .
Pot assy. complete 200 ohms, 25w forfoot throttle confirming to hillgraham part no. : f119 or equival,1k, 25w pot assembled with spindlelock for active field loss reference. pot should be of imp origine,hand throttle assy complete with dual gang pots each of 1 k ohm, 25w rating (ohmite) .
Read moreLock plate for emu traction motor type 4601 having material and specification as per drg. no. er/kpa/el/tm.4he.3052and lock plate plate shall be zinc plated as per is:1573 classification fe/zn 7.5
Lock plate for emu traction motor type 4601 having material and specification as per drg. no. er/kpa/el/tm.4he.3052and lock plate plate shall be zinc plated as per is:1573 classification fe/zn 7.5
Read moreof your Industry type