Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Repairing And Fixing Of Wti And Oit And Buchholz Relay Along With Painting Of One (01) No. 11 Kv/3.3 Kv, 3 Mva And One No. 11 Kv/3.3 Kv, 2.5 Mva Transformer At 02 No. Sub Station Considering Dgms Guideline And Safety Of The Equipment Under Katahra Collier
|
| Description |
Repairing And Fixing Of Wti And Oit And Buchholz Relay Along With Painting Of One (01) No. 11 Kv/3.3 Kv, 3 Mva And One No. 11 Kv/3.3 Kv, 2.5 Mva Transformer At 02 No. Sub Station Considering Dgms Guideline And Safety Of The Equipment Under Katahra Collier
|
| Organisation | Central Coalfields Limited | Public Sector Undertakings |
| Tender Id | 2025_CCL_338353_1 |
|
Reference Number |
KTC/PE/EnM/25-26/18 date-26.06.2025 |
| Tender Fee | 0 |
| EMD | 6300 |
| Tender Value | - |
| Place | Office of the Project Officer, PE (EnM), Kathara C |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=350740 |
| Start Date | June 26, 2025 15:30 |
| End Date |
Expired
07/07/2025
Expired 463 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Dismantling of 3mva, 11kv/3.3kv and re-installation of 3mva, 11kv/3.3kv, power transformer with repairing of one no. vcb at zero point sub-station of gvp ph-ii ocp.
Dismantling of 3mva, 11kv/3.3kv and re-installation of 3mva, 11kv/3.3kv, power transformer with repairing of one no. vcb at zero point sub-station of gvp ph-ii ocp.
 
Read moreDoor locking for interlocking with tripping circuit and providing and fixing of wti, oti, ngr relay etc in 3mva 11kv/3.3kv colony transformer and repairing of capacitor bank at 2x3mva, 11kv/3.3kv substation under rohini ocp, nk area
Door locking for interlocking with tripping circuit and providing and fixing of wti, oti, ngr relay etc in 3mva 11kv/3.3kv colony transformer and repairing of capacitor bank at 2x3mva, 11kv/3.3kv substation under rohini ocp, nk area
Read moreRepairing (02 nos.) of buchholz relay wti and oti protective device of 2mva,11kv/3.3kv transformer at budora substation and repairing of 1250kva,11kv/3.3kv transformer for controlling of power transformer at benidih substation of phularitand,ampc.
Repairing (02 nos.) of buchholz relay wti and oti protective device of 2mva,11kv/3.3kv transformer at budora substation and repairing of 1250kva,11kv/3.3kv transformer for controlling of power transformer at benidih substation of phularitand,ampc.
Read moreRepairing and reconditioning of protective device of (a) 2 mva power transformer, volts-11kv/3.3kv, 04-no. colony feeder (b) 1 mva 11kv/3.3kv cpp feeder (c) 3mva, 33kv/11kv staff feeder and (d) 3mva 33kv/11kv ktc feeder installed at regional sub-stat
Repairing and reconditioning of protective device of (a) 2 mva power transformer, volts-11kv/3.3kv, 04-no. colony feeder (b) 1 mva 11kv/3.3kv cpp feeder (c) 3mva, 33kv/11kv staff feeder and (d) 3mva 33kv/11kv ktc feeder installed at regional sub-stat
Read morePart rewinding and repairing of 3mva 11kv/3.3kv power transformers of religara colliery under argada area.
Part rewinding and repairing of 3mva 11kv/3.3kv power transformers of religara colliery under argada area.
Read moreTapping and providing power arrangement to newly installed 3mva, 11kv/3.3kv power transformer in respect of iwsp, bnk area.
Tapping and providing power arrangement to newly installed 3mva, 11kv/3.3kv power transformer in respect of iwsp, bnk area.
Read moreProviding and fixing safety devices buchholz relay,wti and oti, explosion vent and conservator tank of (1) 1 mva transformer 11kv/3.3 kv and (2) 1.6 mva transformer 11kv/3.3kv installed at new filter house sub-station under jarangdih colliery.
Providing and fixing safety devices buchholz relay,wti and oti, explosion vent and conservator tank of (1) 1 mva transformer 11kv/3.3 kv and (2) 1.6 mva transformer 11kv/3.3kv installed at new filter house sub-station under jarangdih colliery.
Read moreComplete overhauling of transformer of 3mva, 11kv/3.3kv, make-andrew yule, sl.no. 11365 at main sub-station of gvp ph-ii ocp.
Complete overhauling of transformer of 3mva, 11kv/3.3kv, make-andrew yule, sl.no. 11365 at main sub-station of gvp ph-ii ocp.
Read moreProviding and fixing a safety device like buchholz relay, oil, and winding temperature meter and connecting with tripping device to both 3mva, 11kv/3.3kv power transformer i.) make- g.e.c., amp. 157.6/525.5, 3 phase, 50hz., sl. no. ct4368/b-24065 and
Providing and fixing a safety device like buchholz relay, oil, and winding temperature meter and connecting with tripping device to both 3mva, 11kv/3.3kv power transformer i.) make- g.e.c., amp. 157.6/525.5, 3 phase, 50hz., sl. no. ct4368/b-24065 and
Read moreProposal for repairing of crompton parkinson make ocb 400a, ctr-100/5a, 11kv switch gear main controlling of 3mva 11kv/3.3kv transformer at langri more sub-station at docp.
Proposal for repairing of crompton parkinson make ocb 400a, ctr-100/5a, 11kv switch gear main controlling of 3mva 11kv/3.3kv transformer at langri more sub-station at docp.
Read moreof your Industry type