Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Procurement Of Cable Glands
|
| Description |
Procurement Of Cable Glands
(H4 A1 Y43020)
|
| Organisation | Bharat Heavy Electricals Limited | Public Sector Undertakings |
| Tender Id | 2025_BHEL_52137_1 |
|
Reference Number |
H4A1Y43020 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | BHEL HPEP HYDERABAD |
| Link |
View Original Tender Notice
https://eprocurebhel.co.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=56160 |
| Start Date | August 23, 2025 20:30 |
| End Date |
Expired
24/09/2025
Expired 385 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Glands and joints fire sealant stick,fire retardant coating for surface paint,cable passive fire protection 4hrs,cable coating in aerosol spray form,fire stops system in cable penetrations
Glands and joints fire sealant stick,fire retardant coating for surface paint,cable passive fire protection 4hrs,cable coating in aerosol spray form,fire stops system in cable penetrations
Read moreAnnual service contract for cable laying, jointing, termination, supply and fixing of cable glands, earthing strips and panel bottom fire sealing works related to c and i, dept.at bktpp for two(02)years.
Annual service contract for cable laying, jointing, termination, supply and fixing of cable glands, earthing strips and panel bottom fire sealing works related to c and i, dept.at bktpp for two(02)years.
Read moreNctps i se m ii circle ichs dn foph attending of steam oil leaks in valve glands pipe punctures valve flange bonnet in prds system towards foph by on line sealing method for a period of one year
Nctps i se m ii circle ichs dn foph attending of steam oil leaks in valve glands pipe punctures valve flange bonnet in prds system towards foph by on line sealing method for a period of one year
Read more9mtr hot dip galvanized high mast pole with foundation botls,150w led flood lights ip66,mounting bracket and accessories,electrical control panel with mcb and timer,power cable glands and wiring accessories,freight and transportation,civil foundation material,installation and commission,testing docu and misc
9mtr hot dip galvanized high mast pole with foundation botls,150w led flood lights ip66,mounting bracket and accessories,electrical control panel with mcb and timer,power cable glands and wiring accessories,freight and transportation,civil foundation material,installation and commission,testing docu and misc
Read moreVt pump bowl assembly,suspension assembly with line shaft, bearings,,4-pole, ie3 vertical motor complete,discharge head, sole-base plate, coupling,complete automatic star-delta control,power-control cables, glands, lugs,special erection tools, mandatory spares,third-party inspection and factory performance,packing, freight, transit insurance, unloading,erection, installation, alignment, testing, 8-hour trial
Vt pump bowl assembly,suspension assembly with line shaft, bearings,,4-pole, ie3 vertical motor complete,discharge head, sole-base plate, coupling,complete automatic star-delta control,power-control cables, glands, lugs,special erection tools, mandatory spares,third-party inspection and factory performance,packing, freight, transit insurance, unloading,erection, installation, alignment, testing, 8-hour trial
Read moreBalance valve bush bronze mf123hpb28,disc seal seating bronze mf123hpb16,shaft sleeve sd mf123hpb05,discharge bush bronze mf123hpb29,sleeve nut en 8 mf123hpb03,gland flange bronze mf123hpb04,impeller bronze mf123hpb11b,discharge bush bronze mf123hpb29,impeller lg2 31c,guide tips ci 78072c,balance vlave pb1 70c,seating and bush with screw bblb2 71c,pair of sleeve lg2 6365c,set of 2 glands brass 26c,suction cover ci 41c,middle body ci 77c,bearing hsng set of 2 de and nde ci 22c,partition plate ci 78076,set of 2 bearing bushes lb 2 23c
Balance valve bush bronze mf123hpb28,disc seal seating bronze mf123hpb16,shaft sleeve sd mf123hpb05,discharge bush bronze mf123hpb29,sleeve nut en 8 mf123hpb03,gland flange bronze mf123hpb04,impeller bronze mf123hpb11b,discharge bush bronze mf123hpb29,impeller lg2 31c,guide tips ci 78072c,balance vlave pb1 70c,seating and bush with screw bblb2 71c,pair of sleeve lg2 6365c,set of 2 glands brass 26c,suction cover ci 41c,middle body ci 77c,bearing hsng set of 2 de and nde ci 22c,partition plate ci 78076,set of 2 bearing bushes lb 2 23c
Read more1 fp jb 4 way 4 nos 0.5 inch double compression glands ex d iia iib ip66,2 fp switch socket 5 pin 3 phase 415v ac ex d iia iib ip66,3 fp switch socket 3 pin 1 phase 16a 240v ac ex d iia iib ip66,4 jb 1 incoming 3c x 16 sqmm and 6 outgoing 3c x 2.5 sqmm with dc glands,5 fp switch socket 3 pin 1 phase 24v ac with built in 240v ac x 24v ac isolation transformer ex d iia iib ip66,6 fp db 3 phase 415v ac 63a 4p mcb 100ma 4p rccb 12 outgoing 6a dp mcb ex d iia iib ip66,7 fp portable db 63a 5 pin 32a 5 pin 2 nos 16a 3 pin with trolley ex d iic t6 ip66,8 hd fp exhaust fan 300 mm ex d iic t6 ip66,9 fp power jb ex d iia iib zone 1 and 2 ip66 4 busbar 1 incoming 3.5c x 300 sqmm 2 outgoing 3.5c x 95 sqmm,10 fp power jb ex d iia iib zone 1 and 2 ip66 4 busbar 1 incoming 3.5c x 120 to 150 sqmm 2 outgoing 3.5c x 95 sqmm 1 outgoing 3.5c x 35 sqmm,11 fp power jb ex d iia iib zone 1 and 2 ip66 4 busbar 3 incoming 3.5c x 35 sqmm 6 outgoing 3.5c x 4 sqmm,12 fp jb 4 way ex d iia iib ip66 3.5c x 50 sqmm,13 fp jb 4 way ex d iia iib
1 fp jb 4 way 4 nos 0.5 inch double compression glands ex d iia iib ip66,2 fp switch socket 5 pin 3 phase 415v ac ex d iia iib ip66,3 fp switch socket 3 pin 1 phase 16a 240v ac ex d iia iib ip66,4 jb 1 incoming 3c x 16 sqmm and 6 outgoing 3c x 2.5 sqmm with dc glands,5 fp switch socket 3 pin 1 phase 24v ac with built in 240v ac x 24v ac isolation transformer ex d iia iib ip66,6 fp db 3 phase 415v ac 63a 4p mcb 100ma 4p rccb 12 outgoing 6a dp mcb ex d iia iib ip66,7 fp portable db 63a 5 pin 32a 5 pin 2 nos 16a 3 pin with trolley ex d iic t6 ip66,8 hd fp exhaust fan 300 mm ex d iic t6 ip66,9 fp power jb ex d iia iib zone 1 and 2 ip66 4 busbar 1 incoming 3.5c x 300 sqmm 2 outgoing 3.5c x 95 sqmm,10 fp power jb ex d iia iib zone 1 and 2 ip66 4 busbar 1 incoming 3.5c x 120 to 150 sqmm 2 outgoing 3.5c x 95 sqmm 1 outgoing 3.5c x 35 sqmm,11 fp power jb ex d iia iib zone 1 and 2 ip66 4 busbar 3 incoming 3.5c x 35 sqmm 6 outgoing 3.5c x 4 sqmm,12 fp jb 4 way ex d iia iib ip66 3.5c x 50 sqmm,13 fp jb 4 way ex d iia iib
Read moreSitc of 4 mp fixed lens bullet ip camera, complete with mounting, termination, installation, configuration, testing and commissioning,sitc of 4 mp motorized varifocal bullet ip camera, complete with mounting, termination, installation, configuration, testing and commissioning,sitc of 16 channel nvr with 4 sata ports, complete with hdd installation, configuration, integration, testing and commissioning,sitc of 16-port gigabit easy smart poe plus switch with 2 sfp slots and minimum 250 w poe budget, complete with rack mounting, configuration, integration, testing and commissioning,sitc of 20 tb surveillance-grade hdd, complete with nvr installation, initialization, formatting, configuration, testing and commissioning,sitc of 9u network rack, loaded, complete with pdu, cable management, mounting hardware, earthing or bonding, installation, dressing, testing and commissioning,sitc of ip65 rated junction box, complete with cable glands, connectors, mounting hardware, installation, cable termination and sealing,sit
Sitc of 4 mp fixed lens bullet ip camera, complete with mounting, termination, installation, configuration, testing and commissioning,sitc of 4 mp motorized varifocal bullet ip camera, complete with mounting, termination, installation, configuration, testing and commissioning,sitc of 16 channel nvr with 4 sata ports, complete with hdd installation, configuration, integration, testing and commissioning,sitc of 16-port gigabit easy smart poe plus switch with 2 sfp slots and minimum 250 w poe budget, complete with rack mounting, configuration, integration, testing and commissioning,sitc of 20 tb surveillance-grade hdd, complete with nvr installation, initialization, formatting, configuration, testing and commissioning,sitc of 9u network rack, loaded, complete with pdu, cable management, mounting hardware, earthing or bonding, installation, dressing, testing and commissioning,sitc of ip65 rated junction box, complete with cable glands, connectors, mounting hardware, installation, cable termination and sealing,sit
Read moreN plus1 modular type 10 kva ups,static transfer switch with 24u rack with power strip,surge protection devices class b plus c or type 1 plus 2,surge protection devices class c or type,client station cpu with 55 inch or bigger led,client pc with 23 inch monitor along with other accessories,ups cms server each with 23 inch display,ups cms software for and client position,isolation transformer,fire resistant cable multi strand 03 core 6 sq mm,type b curve double pole mcbs 32 amp,type b curve double pole mcbs 63 amp,wall mounted polycarbonate enclosure with transparent door,metallic square channel minimum 3 inches wide,stainless steel flexible conduits minimum 1point5 inches wide,heavy duty copper lugs or thimbles as per power cables,metallic cable glands as per outer diameter of power cables,single core multistrand 6 sq mm copper cable,cost of installation integration testing and commissioning of complete system
N plus1 modular type 10 kva ups,static transfer switch with 24u rack with power strip,surge protection devices class b plus c or type 1 plus 2,surge protection devices class c or type,client station cpu with 55 inch or bigger led,client pc with 23 inch monitor along with other accessories,ups cms server each with 23 inch display,ups cms software for and client position,isolation transformer,fire resistant cable multi strand 03 core 6 sq mm,type b curve double pole mcbs 32 amp,type b curve double pole mcbs 63 amp,wall mounted polycarbonate enclosure with transparent door,metallic square channel minimum 3 inches wide,stainless steel flexible conduits minimum 1point5 inches wide,heavy duty copper lugs or thimbles as per power cables,metallic cable glands as per outer diameter of power cables,single core multistrand 6 sq mm copper cable,cost of installation integration testing and commissioning of complete system
Read moreof your Industry type