Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
M. C. C. B, 3 Pole, 415 V. , 50 Hz, 300 Amp. Breaking Cap. 50 Ka Confirming To Iec 60947 2 With Adjestab
|
| Description |
|
| Organisation | Department of Defence Production | Ministry of Defence |
| Tender Id | GEM/2025/B/6376629 |
|
Reference Number |
- |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link |
View Original Tender Notice
https://bidplus.gem.gov.in/all-bids |
| Start Date | June 24, 2025 23:22 |
| End Date |
Expired
15/07/2025
Expired 458 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Award of Contract & Bid Results
C&s make acb 2500a 415v 3p, ah-25d-cs in 2500a, ue 415v, ui 1000v, icu: ics: 50ka icw(1s) : 50ka,c&s make acb 3200a 415v 3p, ah-30d-cs in 2500a, ue 415v, ui 1000v, icu: ics: 65ka icw(1s) : 65ka,c&s air circuit breaker ah 40d cs, in: 4000a, ue 415 v breaking capacity at 415 v, icu 100ka, ics 1
C&s make acb 2500a 415v 3p, ah-25d-cs in 2500a, ue 415v, ui 1000v, icu: ics: 50ka icw(1s) : 50ka,c&s make acb 3200a 415v 3p, ah-30d-cs in 2500a, ue 415v, ui 1000v, icu: ics: 65ka icw(1s) : 65ka,c&s air circuit breaker ah 40d cs, in: 4000a, ue 415 v breaking capacity at 415 v, icu 100ka, ics 1
Read moreHrc fuse 25 amp, rated voltage 415-690, breaking capacity 80 ka, utilization category gg clip in offset tag type, is:13703 (part-ii)/ iec:60269-2 suitable for ebc in lhb ac coaches, confirming to edts 163 (rev-c) or latest.makes: bussmann, ferraz as per bill of material of rcf specification no.edts163, (rev-c) or latest.
Hrc fuse 25 amp, rated voltage 415-690, breaking capacity 80 ka, utilization category gg clip in offset tag type, is:13703 (part-ii)/ iec:60269-2 suitable for ebc in lhb ac coaches, confirming to edts 163 (rev-c) or latest.makes: bussmann, ferraz as per bill of material of rcf specification no.edts163, (rev-c) or latest.
Read moreL and t hrc fuse 160a hn160 cat no sf 94131,fuse switch type fb 250 l and t,switches of 125a cat 415v sk95001,sdf type fn 630 tpn sk95521 l and t,switch disconnector fuse unit fn32,switch fuse unit 400a 415v tpn sh steel,mccb rating 400a 3pole 50ka,mccb dn0 100m 100a tm release l and t make,mccb mtx 2 0 dn2 250n 250a l and t make,add on block for ml10 12 contactor l and t,l and t make 110a ac3 ml6 contactor,power contactor 240v ac ty mnx400,power contactor 4 p 325a ty mcx 41,32 50 a bimetallic over load relay,mccb 125a,3 2 5 a over load relay,overload relay bimetalic
L and t hrc fuse 160a hn160 cat no sf 94131,fuse switch type fb 250 l and t,switches of 125a cat 415v sk95001,sdf type fn 630 tpn sk95521 l and t,switch disconnector fuse unit fn32,switch fuse unit 400a 415v tpn sh steel,mccb rating 400a 3pole 50ka,mccb dn0 100m 100a tm release l and t make,mccb mtx 2 0 dn2 250n 250a l and t make,add on block for ml10 12 contactor l and t,l and t make 110a ac3 ml6 contactor,power contactor 240v ac ty mnx400,power contactor 4 p 325a ty mcx 41,32 50 a bimetallic over load relay,mccb 125a,3 2 5 a over load relay,overload relay bimetalic
Read moreMotor protection circuit breaker (mpcb) for compressor unit and heater unit, current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3-pole, voltage rating 415 v ac, conforming to is/iec 60947-2; conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1); suitable for use in switch board cabinet of lhb type ac coaches. accepted make & cat. /model no.: rdso-approved make and model as per serial no. 39 of rdso letter no. el/7.1.108/mssbc dated 17.09.2
Motor protection circuit breaker (mpcb) for compressor unit and heater unit, current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3-pole, voltage rating 415 v ac, conforming to is/iec 60947-2; conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1); suitable for use in switch board cabinet of lhb type ac coaches. accepted make & cat. /model no.: rdso-approved make and model as per serial no. 39 of rdso letter no. el/7.1.108/mssbc dated 17.09.2
Read more3 kvar metalized polypropylene gas filled, wavy cut three phase self healing type capacitors, rated at 480v, 50hz , rated current 3.6 amps. capacitor should have discharge resistor and over pressure disconnection as per rdso modification sheet no. rdso/pe/ms/ac/0054-2011 (rev-1)/latest and confirming to is: 13340 (part-1) : 2012 / iec 60831-1:2002/latest with isi mark suitable for capacitor bank of lhb ac coach. acceptable makes: m/s epcos or m/s vishay or any other equivalent capacitor confir
3 kvar metalized polypropylene gas filled, wavy cut three phase self healing type capacitors, rated at 480v, 50hz , rated current 3.6 amps. capacitor should have discharge resistor and over pressure disconnection as per rdso modification sheet no. rdso/pe/ms/ac/0054-2011 (rev-1)/latest and confirming to is: 13340 (part-1) : 2012 / iec 60831-1:2002/latest with isi mark suitable for capacitor bank of lhb ac coach. acceptable makes: m/s epcos or m/s vishay or any other equivalent capacitor confir
Read moreM. c. c. b, 3pole, 415v. , 50hz, 300amp. breaking cap. 50ka confirming to iec 60947-2 with adjestab
Read more
250a, 3pole, 415v, 50hz, 50ka, mccb,400a, 3pole, 415v, 50hz, 50ka, mccb,500a, 3pole, 415v, 50hz, 50
Read more
M. c. c. b, 3pole, 415v, 50hz. 250amps. breaking cap. 50ka confirming to iec60947-2 with adjustable
Read more
of your Industry type