Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Provision Of Earthing For (1) 11 Kv/3.3 Kv, 1.5 Mva Transformer Body And Neutral Point (2) 11 Kv / 440 Volts, 100 Kva Transformer Body And Neutral Point (3) 11 Kv Vcb Body (4) 3.3 Kv Vcb Body And (5) 3.3 Kv Starter Body For Proper Earth Protection
|
| Description |
Provision Of Earthing For (1) 11 Kv/3.3 Kv, 1.5 Mva
Transformer Body And Neutral Point (2) 11 Kv / 440
Volts, 100 Kva Transformer Body And Neutral Point (3)
11 Kv Vcb Body (4) 3.3 Kv Vcb Body And (5) 3.3 Kv
Starter Body For Proper Earth Protection
|
| Organisation | Coal India Limited (CIL) |
| Tender Id | 2023_CCL_288204_1 |
|
Reference Number |
SO(EnM)/PPR/eNIT/23-24/50 |
| Tender Fee | - |
| EMD | 1900 |
| Tender Value | - |
| Place | GM Office, Piparwar Area |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in |
| Start Date | September 07, 2023 16:30 |
| End Date |
Expired
18/09/2023
Expired 1123 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Re-arrangement of bus bar structure, proper gravelling work of main substation for kugp and amc works of 11kv/3.3kv/550v/440v oh lines under kedla ugp, hazaribagh area.
Re-arrangement of bus bar structure, proper gravelling work of main substation for kugp and amc works of 11kv/3.3kv/550v/440v oh lines under kedla ugp, hazaribagh area.
Read morePreventive maintenance of 33kv indoor panel and outdoor breaker of 10 mva, 33kv/11kv andrewyule transformer -2 at southloyabad substation and 11kv vcb of basuria dhansar and gonudhia feeder at godhur switching substation under area
Preventive maintenance of 33kv indoor panel and outdoor breaker of 10 mva, 33kv/11kv andrewyule transformer -2 at southloyabad substation and 11kv vcb of basuria dhansar and gonudhia feeder at godhur switching substation under area
Read moreWork contract for labour charges and transportation for supply and erection of 1no 33 11kv 5mva power transformer and outdoor bay with 33kv outdoor vcb at 33 11kv pillaiyarpalayam ss in respect of kpm region
Work contract for labour charges and transportation for supply and erection of 1no 33 11kv 5mva power transformer and outdoor bay with 33kv outdoor vcb at 33 11kv pillaiyarpalayam ss in respect of kpm region
Read moreVcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Read moreEl.d.c.nosmii/p1/3680/2026 overhauling 4nos 1000 kva oil type transformer including filtration top up of new tr oil 1 no of earth fault relay master relay available in 11kv vcb accessories transport charges available at amma kalaignar maaligai
Overhauling of 4 nos 1000 kva oil type transformer including filtration and top up of new tr oil 1 no of earth fault relay master relay available in the 11 kv vcb accessories transport charges available at amma maaligai muthamizh arignar kalaign
Read moreAnnual maintenance contract (amc) of 01 no substation i/c (integrated circuit) of 11kv ht and lt line and ht metering room contains 11 nos 800 amp 11 kv ht vcb, 6 nos 1600 amp lt acbs and 4 no 1000 amp transformer at gc, crpf jalandhar.
Annual maintenance contract (amc) of 01 no substation i/c (integrated circuit) of 11kv ht and lt line and ht metering room contains 11 nos 800 amp 11 kv ht vcb, 6 nos 1600 amp lt acbs and 4 no 1000 amp transformer at gc, crpf jalandhar.
Read moreHand drill machine 600w 230v 1 point 5 13mm 2800rpm,tester tong 0 to 1000a 660v,3.3kv 400amps fwd off rev isolator part no htsv0003,master trip relay 110v dc cspc86 part no 1907739,puller bearing hyd 10ton,contactor main 550v 300 by 400a,tester hv detector 0 to 11kv for flp switch
Hand drill machine 600w 230v 1 point 5 13mm 2800rpm,tester tong 0 to 1000a 660v,3.3kv 400amps fwd off rev isolator part no htsv0003,master trip relay 110v dc cspc86 part no 1907739,puller bearing hyd 10ton,contactor main 550v 300 by 400a,tester hv detector 0 to 11kv for flp switch
Read more2 core x one and half sq mm pvc insulated copper conductor flexible pvc sheathed cable, 1100 volt,4 sq mm twin core aluminium cable,pvc insulated copper wire thrird fourth square mm , 1 core,copper wire one square mm single core, frlsh, 90mtr in roll,copper wire one and half square mm single core, frlsh, 90mtr in roll,copper wire two and half sq mm single core, frlsh, 90mtr in roll,11kv goab switch vertical type complete with all accessories suitable for 200amps.,11kv triple pole do fuse set,changeover switch 200a. 415v,switch fuse unit with enclosure, rating 200a,single pole mcb of b series 16 a,240 v, 50 hz, 10 ka,240 v, 32amp, singal pole with neutral spn, miniature circuit breaker mcb,240 v, 63amp, singal pole with neutralspn, miniature circuit breaker mcb,mccb 3p 415v 32a,mccb 32 a 4 pole 415 v,mccb 415v 63amp or mccb 63a, 3 pole,four pole mcb 63a, 415v,mccb 100 amp, three pole,mccb, 4 pole, 100a, 415v,mccb 150a,3 pole,mccb 200 amp, three pole,mccb, 4 pole, 200a, 415v,power point combined switch and sock
2 core x one and half sq mm pvc insulated copper conductor flexible pvc sheathed cable, 1100 volt,4 sq mm twin core aluminium cable,pvc insulated copper wire thrird fourth square mm , 1 core,copper wire one square mm single core, frlsh, 90mtr in roll,copper wire one and half square mm single core, frlsh, 90mtr in roll,copper wire two and half sq mm single core, frlsh, 90mtr in roll,11kv goab switch vertical type complete with all accessories suitable for 200amps.,11kv triple pole do fuse set,changeover switch 200a. 415v,switch fuse unit with enclosure, rating 200a,single pole mcb of b series 16 a,240 v, 50 hz, 10 ka,240 v, 32amp, singal pole with neutral spn, miniature circuit breaker mcb,240 v, 63amp, singal pole with neutralspn, miniature circuit breaker mcb,mccb 3p 415v 32a,mccb 32 a 4 pole 415 v,mccb 415v 63amp or mccb 63a, 3 pole,four pole mcb 63a, 415v,mccb 100 amp, three pole,mccb, 4 pole, 100a, 415v,mccb 150a,3 pole,mccb 200 amp, three pole,mccb, 4 pole, 200a, 415v,power point combined switch and sock
Read moreRewinding of 500kva 3.3kv/440 volts to 11kv/440 volts transformer installed at abg colliery under govindpur area
Rewinding of 500kva 3.3kv/440 volts to 11kv/440 volts transformer installed at abg colliery under govindpur area
Read moreRenovation of 11kv/440 volts transformer yard
Renovation of 11kv/440 volts transformer yard and remodeling and relaying of hbg metal in substation and providing fencing with crs masonry in place of damaged including silver enamel painting to 4 pole structure and 500kv transformer at aliabad premises under electrical and mechanical section, eam cell-iv of operations and maintenance division-ii (b) (1st recall)
Read moreof your Industry type