Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Kpm/Rfp/Rm/300/C449/23/23 24
|
| Description |
Defects On Ahu Are As Follows
Structral Frame Of Ahu Blower Corroded And Dammaged Due To Aging And Same To Be Fabricated.
Wobbling Observed On Ahu Motor Pulley And Same To Be Renewed.
Bearing Of Ahu Blower Motor Wornout And The Same
|
| Organisation | Defence eProcurement Portal |
| Tender Id | 2023_ICG_609348_1 |
|
Reference Number |
KPM/RFP/RM/300/C449/23/23-24 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | ICGS Krishnapatnam |
| Link |
View Original Tender Notice
https://defproc.gov.in |
| Start Date | July 17, 2023 19:20 |
| End Date |
Expired
24/07/2023
Expired 1183 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423 e075 sea water leakage observed from exhaust pipe line of port da between exhaust flap valve and hull penetration area leakage needs to be arrested by weldin..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423 e076 ac condenser safety valve discharge pipeline to be routed outside of compartment qty02 nos pipeline length 03 mtr all inway jobs included mat copper dia..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423 e077 01 in no fire hydrant dia 55 mm locking pin deteriorated locking pin to be repaired renewed as per sample service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423 e078 lub oil leakage observed from sme lo replenishment pump discharge pipeline near sump area pipe dia 20 mm length 35 feet mat ms leakage needs to be arres..
Repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423 e075 sea water leakage observed from exhaust pipe line of port da between exhaust flap valve and hull penetration area leakage needs to be arrested by weldin..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423 e076 ac condenser safety valve discharge pipeline to be routed outside of compartment qty02 nos pipeline length 03 mtr all inway jobs included mat copper dia..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423 e077 01 in no fire hydrant dia 55 mm locking pin deteriorated locking pin to be repaired renewed as per sample service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423 e078 lub oil leakage observed from sme lo replenishment pump discharge pipeline near sump area pipe dia 20 mm length 35 feet mat ms leakage needs to be arres..
Read moreRepair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423 h030 firing arc of 12 7 mm hmg and 7 62 mm lmg to be fabricated as per ships gun firing limitation arc service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423 h031 rubber beading of ventilation exhaust flaps 10, doors 07 and hatches 05 deteriorated same to be renewed and proved for gas and water tight operations ap..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423 h032 wind sock securing post to be fabricated at foxle and proved for smooth operation mat aluminium size 2 ft dia 25 mm service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423 h033 bed cushion securing arrangement to be fabricated mat nylon velcro double sided dia 50 mm approx length 60 mtrs service provider
Repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423 h030 firing arc of 12 7 mm hmg and 7 62 mm lmg to be fabricated as per ships gun firing limitation arc service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423 h031 rubber beading of ventilation exhaust flaps 10, doors 07 and hatches 05 deteriorated same to be renewed and proved for gas and water tight operations ap..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423 h032 wind sock securing post to be fabricated at foxle and proved for smooth operation mat aluminium size 2 ft dia 25 mm service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-423 h033 bed cushion securing arrangement to be fabricated mat nylon velcro double sided dia 50 mm approx length 60 mtrs service provider
Read more15 in nos telephone directory plates corroded and deteriorated. same to be renewed as per sample. m
Read more
11seater sofa cover and cushion damaged or colure faded and same to be repaired or renewed and re f
Read more
Ship’ s duty state board perished due to fair wear and tear. same to be renewed as per sample.,25
Read more
Circuit breaker 80 amps emd part no. 400 [circuit breaker 80 amps emd part no. 40066594 for tcc1 blower. note: the tenderer must have supplied the same/ similar items to sc railways, or other zonal railways during last three years prior to, and excluding tender opening date and documentary evidence ( tpi/rites inspection certificates, r/notes ,crn etc.) must be furnished along with their offer evidencing the execution of such purchase orders.]
For complete deion and other details, please refer to tender
Read moreCircuit breaker 80 amps emd part no. 400 [circuit breaker 80 amps emd part no. 40066594 for tcc1 blower. note: the tenderer must have supplied the same/ similar items to sc railways, or other zonal railways during last three years prior to, and excluding tender opening date and documentary evidence ( tpi/rites inspection certificates, r/notes ,crn etc.) must be furnished along with their offer evidencing the execution of such purchase orders.]
For complete deion and other details, please refer to tender
Read moreof your Industry type