Suture Anchor Should Be Made Of Peek Material 4.75 Mm./ Suture Anchor Should Be Made Of Peek Material. 5.5 Mm. / Low Profile Titanium Cancellous Screws Of Diameter 4.0 Mm And 6.5 Mm.
Description
Suture Anchor Should Be Made Of Peek Material 4.75 Mm./ Suture Anchor Should Be Made Of Peek Material. 5.5 Mm. / Low Profile Titanium Cancellous Screws Of Diameter 4.0 Mm And 6.5 Mm.
Organisation Ministry of Railways
Tender Id Login to view
Reference
Number
Login to view
Tender Fee -
EMD -
Tender Value -
Place
Link Login to view
Start Date October 14, 2026 18:41
End Date
Open 27/10/2026

10 days left

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Needle for inside-out meniscal repair with eye for thread.1. standard-length stainless steel with a 38cm or more in length and diameter should be 0.8 mm or less. 2. should be made up of high strength, flexible stainless steel, 3. needle should have eye on non-sharp end to pass minimum 2-0 suture. 4. needles can be used with other meniscal repair systems. (as per detailed specifications attached)

Needle for inside-out meniscal repair with eye for thread.1. standard-length stainless steel with a 38cm or more in length and diameter should be 0.8 mm or less. 2. should be made up of high strength, flexible stainless steel, 3. needle should have eye on non-sharp end to pass minimum 2-0 suture. 4. needles can be used with other meniscal repair systems. (as per detailed specifications attached)

Read more
Disposable presterilised meniscal repair suture passing system with polyethylene button or anchor and 1 to 0 multi strand,meniscal cinch for all inside meniscal repair,all inside meniscal repair implant system.,titanium anchor 2.8 2.4 3.5 5.0 mm components as under,bio anchor 2.8mm 2.4 3.5 5.0mm,suture disc for acl pcl reconstruction titanium all sizes pre sterilised.,titanium endobutton with adjustible length suspensory loop made of suture made of uhwpe core with braided fixation of tendon graft,end resector for arthroscopic shaver system disposable presterilised 3 to 5.5 cm diam,arthroscopic burr all types including acromioplasty burr and conical burrs size 3 to 5.5 mm disposable presterilised,sterile packed cork screw 4.5 mm anchorwith 2 x no. 2 preloaded suture made of uhwpe core cuff repair,sterile packed cork screw 6.5 mm anotator cuff repair,sterile packed bioabsorbable anchor with single loaded sliding suture made of uhwpe core with braided polyester jacket 2.4 2.8 3.5 mm,sterile packed titanium ancho

Disposable presterilised meniscal repair suture passing system with polyethylene button or anchor and 1 to 0 multi strand,meniscal cinch for all inside meniscal repair,all inside meniscal repair implant system.,titanium anchor 2.8 2.4 3.5 5.0 mm components as under,bio anchor 2.8mm 2.4 3.5 5.0mm,suture disc for acl pcl reconstruction titanium all sizes pre sterilised.,titanium endobutton with adjustible length suspensory loop made of suture made of uhwpe core with braided fixation of tendon graft,end resector for arthroscopic shaver system disposable presterilised 3 to 5.5 cm diam,arthroscopic burr all types including acromioplasty burr and conical burrs size 3 to 5.5 mm disposable presterilised,sterile packed cork screw 4.5 mm anchorwith 2 x no. 2 preloaded suture made of uhwpe core cuff repair,sterile packed cork screw 6.5 mm anotator cuff repair,sterile packed bioabsorbable anchor with single loaded sliding suture made of uhwpe core with braided polyester jacket 2.4 2.8 3.5 mm,sterile packed titanium ancho

Read more
Universal extremity drape sms fabric and dimension,ss wire rolls,variable angle 3.5mm locking tubular plate 8 holes with 6 nos,high tibial osteotomy plate puddu type size 7.5 holes,suture anchor,suture anchor, dia 2.8mm,flip cutters,disposable suture passer left,disposable suture passer right,camera cover for arthroscopy,all suture anchors in size 1.8mm,all suture anchors in size 2.8mm,arthroscopic shaver blade,tight rope for fixation,spiked staple,endoscopic reamer,cannulated reamers,knitted fibreglass impregnated resin cast rolls10 cm width,resistance exercise bands,drill bits 2.5 mm,drill bits 3.2 mm,drill bits 4.5 mm,bio anchor,rci tibial tapered screw,hydroxyapatite coated schanz pin size,hydroxyapatite coated tapered schanz pin size,drill bits solid 2.5 mm,drill bits solid 3.2 mm,calibrated cannulated drill bits,cortical screws, large fragment, 4.5 mm,cortical screws, small fragment, 3.5 mm,cannulated cancellous screws 4.0 mm partially threaded ti,locking screw, large fragment 5.0 mm,minifragment plate

Universal extremity drape sms fabric and dimension,ss wire rolls,variable angle 3.5mm locking tubular plate 8 holes with 6 nos,high tibial osteotomy plate puddu type size 7.5 holes,suture anchor,suture anchor, dia 2.8mm,flip cutters,disposable suture passer left,disposable suture passer right,camera cover for arthroscopy,all suture anchors in size 1.8mm,all suture anchors in size 2.8mm,arthroscopic shaver blade,tight rope for fixation,spiked staple,endoscopic reamer,cannulated reamers,knitted fibreglass impregnated resin cast rolls10 cm width,resistance exercise bands,drill bits 2.5 mm,drill bits 3.2 mm,drill bits 4.5 mm,bio anchor,rci tibial tapered screw,hydroxyapatite coated schanz pin size,hydroxyapatite coated tapered schanz pin size,drill bits solid 2.5 mm,drill bits solid 3.2 mm,calibrated cannulated drill bits,cortical screws, large fragment, 4.5 mm,cortical screws, small fragment, 3.5 mm,cannulated cancellous screws 4.0 mm partially threaded ti,locking screw, large fragment 5.0 mm,minifragment plate

Read more
Pacer with mask for child [srphc82337065-spacer with mask for children.1)it should be suitable for use for infants and children.2)the minimum capacity of the holding chamber should be approximately 250cc(ml).3)the holding chamber should have a valve to prevent rebreathing of the exhaled air.4)should be made of polymer /polycarbonated material.5)should have a mask of pediatric size suitable for covering the nose and mouth of the infant and children.6)should be compatible with the mdi which is b

Pacer with mask for child [srphc82337065-spacer with mask for children.1)it should be suitable for use for infants and children.2)the minimum capacity of the holding chamber should be approximately 250cc(ml).3)the holding chamber should have a valve to prevent rebreathing of the exhaled air.4)should be made of polymer /polycarbonated material.5)should have a mask of pediatric size suitable for covering the nose and mouth of the infant and children.6)should be compatible with the mdi which is b

Read more
1) breathable impervious surgical gown should be an intelligent and high-performance gowna made up of 60-gsm light weight trilaminate material. gown should provide full imperviousness to blood-borne pathogens and should meet thea standards set by aami pb70, astm f1671, and en 13795. breathable membrane should reactsa to body temperature changes, to enhance water vapor transmission for wearer comfort.a gown should be available in xl (130 cm), xll (150 cm), and 2 xll (150 cm) with raglan sleeves

1) breathable impervious surgical gown should be an intelligent and high-performance gowna made up of 60-gsm light weight trilaminate material. gown should provide full imperviousness to blood-borne pathogens and should meet thea standards set by aami pb70, astm f1671, and en 13795. breathable membrane should reactsa to body temperature changes, to enhance water vapor transmission for wearer comfort.a gown should be available in xl (130 cm), xll (150 cm), and 2 xll (150 cm) with raglan sleeves

Read more
Disposable rotatable rat tooth forceps should have 1. rat tooth / alligator jaw with opening width of 3.8 mm to 7.2 mm and compatible with 2.8 mm instrument channel. 2. firm grip & easy movould be available with rotatable graspers. 3. shaft length more than 160cm and jaw opening from 11.3mm to 14.9mm. 4.should be made of medical grade stainless steel with ptfe

Disposable rotatable rat tooth forceps should have 1. rat tooth / alligator jaw with opening width of 3.8 mm to 7.2 mm and compatible with 2.8 mm instrument channel. 2. firm grip & easy movould be available with rotatable graspers. 3. shaft length more than 160cm and jaw opening from 11.3mm to 14.9mm. 4.should be made of medical grade stainless steel with ptfe

Read more
Olonic metal uncovered st [srphc82336085-colonic metal uncovered stent should be made of alloy material to allow greater flexibility and use in tortuous anatomy. should have various lengths 6 or 8 or 10cm. should have a 30mm flare and 25mm body and reconstrainable even after 70 percent of deployment.] ,ontrolled radial expansio [srphc82336090-controlled radial expansion esophageal balloon dilator: 1. balloon made of pebax (polyether block amide or peba is a thermoplastic elastomer), a non-co

Olonic metal uncovered st [srphc82336085-colonic metal uncovered stent should be made of alloy material to allow greater flexibility and use in tortuous anatomy. should have various lengths 6 or 8 or 10cm. should have a 30mm flare and 25mm body and reconstrainable even after 70 percent of deployment.] ,ontrolled radial expansio [srphc82336090-controlled radial expansion esophageal balloon dilator: 1. balloon made of pebax (polyether block amide or peba is a thermoplastic elastomer), a non-co

Read more
Intravascular lithotripsy intuitive catheter with rx system integrated 12 mm double wall balloon of diameters: 2.5, 3.0, 3.5, 4.0 mm and shockwave intravascular lithotripsy generator. connector cable should be supplied by the firm during case [item code no.: s62272 , ai 26-27]

Intravascular lithotripsy intuitive catheter with rx system integrated 12 mm double wall balloon of diameters: 2.5, 3.0, 3.5, 4.0 mm and shockwave intravascular lithotripsy generator. connector cable should be supplied by the firm during case [item code no.: s62272 , ai 26-27]

Read more
Ortic stent graft :- shou [srphc82281040-aortic stent graft :- should enable endovascular treatment of arch of aorta and descending thoracic aorta aneurysms and dissections. the stent graft should come in various lengths and diameters. it should consist of (1) a self expanding, tubular endoprosthesis composed of a polyester graft fabric and a spring scaffold made from nitinol wire. (2) radiopaque markers are to be sewn to the fabric to radiographically visualize the edge of the graft material

Ortic stent graft :- shou [srphc82281040-aortic stent graft :- should enable endovascular treatment of arch of aorta and descending thoracic aorta aneurysms and dissections. the stent graft should come in various lengths and diameters. it should consist of (1) a self expanding, tubular endoprosthesis composed of a polyester graft fabric and a spring scaffold made from nitinol wire. (2) radiopaque markers are to be sewn to the fabric to radiographically visualize the edge of the graft material

Read more
One piece femoral adult arterial cannula. 1) it should have a micro-port tips, made of a one piece material and kink resistant 2) cannula length 17 inche(43.2 cm) overall length with 7.1 in(18 cm) tip it should offer a high flow rate with minimal pressure differntial. 3) cannula should have a introducer along with depth markings to precise the position of the cannulae.should be vented 3/8 in(0.95 cm) connector. size 19 fr biomedicus. cat no.96570 - 019.

One piece femoral adult arterial cannula. 1) it should have a micro-port tips, made of a one piece material and kink resistant 2) cannula length 17 inche(43.2 cm) overall length with 7.1 in(18 cm) tip it should offer a high flow rate with minimal pressure differntial. 3) cannula should have a introducer along with depth markings to precise the position of the cannulae.should be vented 3/8 in(0.95 cm) connector. size 19 fr biomedicus. cat no.96570 - 019.