Tender Details

Particulars Details
Title
69166 Lateral Row Anchor For Double Row Rotator Cuff Repair. 1. It Should Be Knotless, Peek, Self Punching Anchor 2. The Implant Should Have Sharp Titanium Eyelet Tip It Should Hold Minimum Six Sutures. 3. The Anchor Should Be Vented And Should Work As Interference Screw Mechanism For Final Fixation. 4. Anchor Should Have Facility Of Final Thread Tightening.
Description
For Complete Deion And Other Details, Please Refer To Tender
Organisation Ministry of Railways | Central Govt. Ministry/Department
Tender Id 73928951
Reference
Number
H1245092
Tender Fee 0
EMD 0
Tender Value -
Place Mumbai CST
Link
View Original Tender Notice

https://www.ireps.gov.in/ireps/supply/pdfdocs/062024/106380282/viewNitPdf_4612884.pdf

Start Date June 20, 2024 18:45
End Date
Expired 28/06/2024

Expired 841 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Suture anchor should be made of peek material 4.75mm./ suture anchor should be made of peek material. 5.5 mm. / low profile titanium cancellous screws of diameter 4.0 mm and 6.5mm.

Suture anchor should be made of peek material 4.75mm./ suture anchor should be made of peek material. 5.5 mm. / low profile titanium cancellous screws of diameter 4.0 mm and 6.5mm.

Read more
The nitinol core coronary wire - width should be 0.014 in diameter and length of 180 cm or more. the tip weight should be less than one gram. should have hydrophilic coating. should have 1:1 torquability. should be compatible with dock extension wire

The nitinol core coronary wire - width should be 0.014 in diameter and length of 180 cm or more. the tip weight should be less than one gram. should have hydrophilic coating. should have 1:1 torquability. should be compatible with dock extension wire

Read more
Chlorine tablets for use in ir-drdo bio-toilets confirming to rcf specification mdts-14274 rev-00. technical requirements: 1. the tablet size should be 78 mm diameter and weight should be of approximately 200 g. 2. the tablet should have active molecule of 3, 5 di-chloro-isocyanuric-acid. 3. it should have effective chlorine of >= 50 percent chlorine. 4. the tablet should have formulated for sustained release (should last for at least 21 days in tap water). 5. moisture content should be

Chlorine tablets for use in ir-drdo bio-toilets confirming to rcf specification mdts-14274 rev-00. technical requirements: 1. the tablet size should be 78 mm diameter and weight should be of approximately 200 g. 2. the tablet should have active molecule of 3, 5 di-chloro-isocyanuric-acid. 3. it should have effective chlorine of >= 50 percent chlorine. 4. the tablet should have formulated for sustained release (should last for at least 21 days in tap water). 5. moisture content should be

Read more
Pacer with mask for child [srphc82337065-spacer with mask for children.1)it should be suitable for use for infants and children.2)the minimum capacity of the holding chamber should be approximately 250cc(ml).3)the holding chamber should have a valve to prevent rebreathing of the exhaled air.4)should be made of polymer /polycarbonated material.5)should have a mask of pediatric size suitable for covering the nose and mouth of the infant and children.6)should be compatible with the mdi which is b

Pacer with mask for child [srphc82337065-spacer with mask for children.1)it should be suitable for use for infants and children.2)the minimum capacity of the holding chamber should be approximately 250cc(ml).3)the holding chamber should have a valve to prevent rebreathing of the exhaled air.4)should be made of polymer /polycarbonated material.5)should have a mask of pediatric size suitable for covering the nose and mouth of the infant and children.6)should be compatible with the mdi which is b

Read more
Floor end profile,l=2000mm, as per drawing: lw41112, packing instruction: as per standard packing. it should be ensured that item should not rub during transportation.the item should be packed with adequate strength.

Floor end profile,l=2000mm, as per drawing: lw41112, packing instruction: as per standard packing. it should be ensured that item should not rub during transportation.the item should be packed with adequate strength.

Read more
Carbide sludge containing minimum 50 cao (on dry basis) . it should be free from grits, stone, lumps

Carbide sludge containing minimum 50 cao (on dry basis) . it should be free from grits, stone, lumps

Read more
One piece femoral adult arterial cannula. 1) it should have a micro-port tips, made of a one piece material and kink resistant 2) cannula length 17 inche(43.2 cm) overall length with 7.1 in(18 cm) tip it should offer a high flow rate with minimal pressure differntial. 3) cannula should have a introducer along with depth markings to precise the position of the cannulae.should be vented 3/8 in(0.95 cm) connector. size 19 fr biomedicus. cat no.96570 - 019.

One piece femoral adult arterial cannula. 1) it should have a micro-port tips, made of a one piece material and kink resistant 2) cannula length 17 inche(43.2 cm) overall length with 7.1 in(18 cm) tip it should offer a high flow rate with minimal pressure differntial. 3) cannula should have a introducer along with depth markings to precise the position of the cannulae.should be vented 3/8 in(0.95 cm) connector. size 19 fr biomedicus. cat no.96570 - 019.

Read more
Intubating catheter/bougie 14 french 70 cm long - (1) it should facilitate endotracheal intubation in patients when visualisation of the glottis is inadequate. (2). introducer should be a 14 french 70 cm long radio opaque catheter for adults (3). the tip should be blunt and angled to assist in proper placement beyond the vocal cords and to minimise trauma to internal structures. (4). should have 2 removable adapters to permit ventilation. one with a 15mm adapter to connect to ventilating circu

Intubating catheter/bougie 14 french 70 cm long - (1) it should facilitate endotracheal intubation in patients when visualisation of the glottis is inadequate. (2). introducer should be a 14 french 70 cm long radio opaque catheter for adults (3). the tip should be blunt and angled to assist in proper placement beyond the vocal cords and to minimise trauma to internal structures. (4). should have 2 removable adapters to permit ventilation. one with a 15mm adapter to connect to ventilating circu

Read more
Humerus multilock nail set [srphc82414005-humerus multilock nail set should consist of reamed humerus nail with 4.5mm multilock blunt screws and 2 locking scrws. it should be available in diameter of 7,8,8.5,9.5mm with length ranging from 160 -300mm. itshould have polyethylene inlay with options of 3.5 and 4mm locking screws with complete set of instrumentation. unit:set]

Humerus multilock nail set [srphc82414005-humerus multilock nail set should consist of reamed humerus nail with 4.5mm multilock blunt screws and 2 locking scrws. it should be available in diameter of 7,8,8.5,9.5mm with length ranging from 160 -300mm. itshould have polyethylene inlay with options of 3.5 and 4mm locking screws with complete set of instrumentation. unit:set]

Read more
Needle for inside-out meniscal repair with eye for thread.1. standard-length stainless steel with a 38cm or more in length and diameter should be 0.8 mm or less. 2. should be made up of high strength, flexible stainless steel, 3. needle should have eye on non-sharp end to pass minimum 2-0 suture. 4. needles can be used with other meniscal repair systems. (as per detailed specifications attached)

Needle for inside-out meniscal repair with eye for thread.1. standard-length stainless steel with a 38cm or more in length and diameter should be 0.8 mm or less. 2. should be made up of high strength, flexible stainless steel, 3. needle should have eye on non-sharp end to pass minimum 2-0 suture. 4. needles can be used with other meniscal repair systems. (as per detailed specifications attached)

Read more
Click Here to Download Dockets
of your Industry type
Get customized tender Recommendations for your Enterprise