Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Ct, 100/1 Amp 5 P10, 3 Va Outdoor Underframe Mounted For Igbt Acemu Trfr As Per Drg 34661950070 Rev 0
|
| Description |
|
| Organisation | Department of Heavy Industry | Ministry of Heavy Industries and Public Enterprises |
| Tender Id | GEM/2025/B/6050798 |
|
Reference Number |
- |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link |
View Original Tender Notice
https://bidplus.gem.gov.in/all-bids |
| Start Date | March 12, 2025 21:20 |
| End Date |
Expired
24/03/2025
Expired 572 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Award of Contract & Bid Results
E4963063 11kv and 33kv outdoor ct 01-sg4960097000-11 kv ct ratio ct 600-300_slash_1-1-0.5775a core-1-colon-15va 5p10 core-ii-colon-5va 0.2s core-iii-colon-cl.ps vk as per ann-a it-01,02-sg4960097019-33 kv ct ratio 400-200-100_slash_1-1-1 a core-1-colon-15va 5p10 core-ii-colon-5va 0.2s core-iii-colon-cl.ps vk-40i_rct_plus_10_ at lower tap as per ann-a it-02,03-not to quote,04-not to quote,05-not to quote
E4963063 11kv and 33kv outdoor ct 01-sg4960097000-11 kv ct ratio ct 600-300_slash_1-1-0.5775a core-1-colon-15va 5p10 core-ii-colon-5va 0.2s core-iii-colon-cl.ps vk as per ann-a it-01,02-sg4960097019-33 kv ct ratio 400-200-100_slash_1-1-1 a core-1-colon-15va 5p10 core-ii-colon-5va 0.2s core-iii-colon-cl.ps vk-40i_rct_plus_10_ at lower tap as per ann-a it-02,03-not to quote,04-not to quote,05-not to quote
Read moreCt, 100/1 amp. , 5p10, 3va outdoor underframe mounted for igbt acemu trfr as per drg 34661950070 re
Read more
Ct, 100/1 amp. , 5p10, 3va outdoor underframe mounted for igbt acemu trfr as per drg 34661950070 re
Read more
Ct, 100/1 amp 5p10, 3va outdoor underframe mounted for igbt acemu trfr as per drg 34661950070 rev 0
Read more
[supply of 33kv outdoor type current transformer oil cooled, outdoor live tank ct ratio : 100-50/1-1a class : 0.5/5p10, burden : 15/30va, stc: 13.1ka/1sec..il : 36/70/170 kvp, with one year warranty ]
For complete deion and other details, please refer to tender
Read moreRing type outdoor mounted neutral ct as per attached annex-a. ratio: core-1: 2000/1 core-2: 1000/1
Ring type outdoor mounted neutral ct as per attached annex-a. ratio: core-1: 2000/1 core-2: 1000/1
Read more33 kv out door type current transformer (ct) oil insulated , live tank outdoor, structure mounted type, single phase 33 kv class . ct ratio - 400-200/5-5a s.t.r. - 25ka for 1.0 sec, bil- 70/170 kvp as per is 2705 (part-ii-iv). make :- sandas & co. or similar.
For complete deion and other details, please refer to tender
Read more33 kv out door type current transformer (ct) oil insulated , live tank outdoor, structure mounted type, single phase 33 kv class . ct ratio - 400-200/5-5a s.t.r. - 25ka for 1.0 sec, bil- 70/170 kvp as per is 2705 (part-ii-iv). make :- sandas & co or similar.
For complete deion and other details, please refer to tender
Read more33 kv current transformer ( rating 200-100 /1-1 a, 1 phase ) oil insulated live tank outdoor structure mounted type, single phase 33 kv class. ct ratio - 200-100/1-1a s.t.r - 25 ka for 1.0 sec. bil- 70/170 kvp as per is 2705 (part -ii-iv). make :- sandas & co or similar
For complete deion and other details, please refer to tender
Read more33 kv current transformer ( rating 200-100 /1-1 a, 1 phase ) oil insulated live tank outdoor structure mounted type, single phase 33 kv class. ct ratio - 200-100/1-1a s.t.r - 25 ka for 1.0 sec. bil- 70/170 kvp as per is 2705 (part -ii-iv). make :- sandas & co or similar.
For complete deion and other details, please refer to tender
Read moreof your Industry type