🚂 Procurement Opportunity For Type F 1 To F 4 Berth Reading Light Fittings 🔦 The Ministry Of Railways, Central Government, Invites Tenders From Reputable Manufacturers For The Supply Of Type F 1 To F 4 Berth Reading Light (Brl) Fittings With Integrated Usb Mobile Charging Socket For Ac 2 Tier Linke Hofmann Busch (Lhb) Coaches. 📅 Submission Deadline: April 17, 2024, 2:30 Pm Tender Submissions Should Adhere To The Specifications Outlined In Rcf Specification No. Mdts 24347, Rev 0, And Comply With The Electrical Requirements, Including Input And Output Voltage Ratings. Proposals From Devintec Electrical Technologies Pvt Ltd, R T Vision, D R Auto, Kaveri, And Integrated Are Particularly Encouraged. Interested Bidders Should Refer To The Tender Document For Complete Details And Submission Guidelines. Keywords: Ministry Of Railways, Berth Reading Light, Usb Charging Socket, Ac 2 Tier Lhb Coaches, Rcf Specification, Tender, Procurement
Particulars Details
Title
Type F 1 To F 4 With Berth Reading Light ( Brl ) Fittings With Integrated Usb Mobile Charging Socket For Ac 2 Tier Lhb Coaches As Per Rcf Specification No. Mdts 24347, Rev 0. Rated Input Voltage: 110 V Ac/Dc (90 V To 140 V Ac/Dc ), Rated Output Voltage: 5 V/9 V Dc. Make : Devintec Electrical Technologies Pvt Ltd / R T Vision / D R Auto, Kaveri And Integ.
Description
For Complete Deion And Other Details, Please Refer To Tender
Organisation Ministry of Railways | Central Govt. Ministry/Department
Tender Id 106296921
Reference
Number
TS235420A
Tender Fee 0
EMD 0
Tender Value -
Place Guwahati
Link
View Original Tender Notice

https://www.ireps.gov.in/ireps/supply/pdfdocs/042024/106296921/viewNitPdf_4515236.pdf

Start Date March 18, 2024 23:38
End Date
Expired 17/04/2024

Expired 912 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Contactor for net 1 & 2 rated voltage: 1 [contactor for net 1 & 2 rated voltage: 1000 v a. c, rated kva- 100 at rated voltage & 70 .

Contactor for net 1 & 2 rated voltage: 1 [contactor for net 1 & 2 rated voltage: 1000 v a. c, rated kva- 100 at rated voltage & 70 .

Read more
Insulation control 415vac, rated voltage 0-500vac, control voltage 24-240v ac/dc etc.

Insulation control 415vac, rated voltage 0-500vac, control voltage 24-240v ac/dc etc.

Read more
Contactor for net 1 & 2 rated voltage: 1000 v a. c

Contactor for net 1 & 2 rated voltage: 1000 v a. c

Read more
Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest

Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest

Read more
Alif make reed switch, model no. ag-39r-02, 2 wire, normally open, operating voltage: 5 -240 v ac/dc

Alif make reed switch, model no. ag-39r-02, 2 wire, normally open, operating voltage: 5 -240 v ac/dc

Read more
Relay module transparent glass type relay module 2 c/o 4 ch relay module coil voltage 24 v dc coil,relay module transparent glass type relay module 2 c/o 4 ch relay module. coil voltage 220 v ac

Relay module transparent glass type relay module 2 c/o 4 ch relay module coil voltage 24 v dc coil,relay module transparent glass type relay module 2 c/o 4 ch relay module. coil voltage 220 v ac

Read more
3 phase measuring and monitoring relay rated voltage looo v ac for net 1 net 2 as per rdso spcn. no. rdso/pe/spec/ac/0184-2015(rev.1)

3 phase measuring and monitoring relay rated voltage looo v ac for net 1 net 2 as per rdso spcn. no. rdso/pe/spec/ac/0184-2015(rev.1)

Read more
Din type high voltage hrc fuse net 1 and net 2, rated current: 125 amps, rated voltage: 1000 v ac, breaking capacity: 80ka suitable for use in lhb eog/hog type ac coaches conforming to rdsos ltr. no. el/7.1.108/mssbc dtd. 17.09.2021. acceptable make : siba [2028003.125] / efen / eti [4182495] / siemens / eaton bussmann [125nh1lir-1000].

Din type high voltage hrc fuse net 1 and net 2, rated current: 125 amps, rated voltage: 1000 v ac, breaking capacity: 80ka suitable for use in lhb eog/hog type ac coaches conforming to rdsos ltr. no. el/7.1.108/mssbc dtd. 17.09.2021. acceptable make : siba [2028003.125] / efen / eti [4182495] / siemens / eaton bussmann [125nh1lir-1000].

Read more
Electro pneumatics regulator model no. -itv3050-344s3, input dc 0-10v, output 0.05-8 bar, voltage dc2,3 port solenoid valve actuator, model no. -vp742-5dz1-04a-f, pressure 0.2-0.7 mpa, voltage 24vdc, pow

Electro pneumatics regulator model no. -itv3050-344s3, input dc 0-10v, output 0.05-8 bar, voltage dc2,3 port solenoid valve actuator, model no. -vp742-5dz1-04a-f, pressure 0.2-0.7 mpa, voltage 24vdc, pow

Read more
Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,

Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,