Tender Details
Particulars | Details |
---|---|
Title |
Aluminum Conductor Welding Cable With General Purpose Hofr Compound Covering With The Following Nominal Area Of Conductor Cable Are At 60 Percent Duty Cycle And 30 Degree Centigrade Ambient Temperature Of The Size 120 Sq.Mm, 522 Amps Conforming To L S: 9857/1990 (Re Affirmed 1995) With Amendment No.1/2007, Technical Specification: 1. Type Of Cable And Core: Single Core Welding Cable (Flexible) 2. Type Of Conductor: Aluminum 3.Cable Size In Square Mm/Rated Current In Amp At 60 Percent Duty Cy
|
Description |
For Complete Deion And Other Details, Please Refer To Tender
|
Organisation | Ministry of Railways | Central Govt. Ministry/Department |
Tender Id | 106492109 |
Reference Number |
LF245213 |
Tender Fee | 0 |
EMD | 0 |
Tender Value | |
Place | Secunderabad |
Link | https://www.ireps.gov.in/ireps/supply/pdfdocs/102024/106492109/viewNitPdf_4736119.pdf |
Start Date | October 08, 2024 14:57 |
End Date |
29/10/2024 ( Expired 173 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Welding copper cable size 50 sq.mm 400 amps confirming to is:9857-1991 with hofr rubber with isi mark (hsn code:8544). make: esab/ador/euro/messer/champion.
For complete deion and other details, please refer to tender
Read moreIsi marked cable flexi welding to welding cable size 50 sq. mm to is: 9857/1990 with general purpose hofr compound covered with copper conductor having nominal area of conductor 360 a at 60 percent duty cycle & 30 degree centigrade ambient temperature. makes: polycab/ finolex/ plaza/ r r cables/ mescab/ havells/ anchor. note: one sample metre should be got approved before effecting bulk supply.
For complete deion and other details, please refer to tender
Read morePortable single operated rectifier type conventional dc arc welding set-600 ampere capacity suitable for manual arc welding process with warranty/guarantee and test certificate. technical specification as given below: 1. maximum hand welding current 60 percent duty cycle 600a and minimum hand welding current 60 percent duty cycle: 120 a 2. open circuit voltage : 70v (max) and operating arc voltage: 25-44 volt. 3. 3-phase 50 hz, rated input voltage: 3 tapings- 380/415/440 volts. 4. type
For complete deion and other details, please refer to tender
Read moreVertical type submersible motor pump capacity-17.5 hp/1217 lpm at 46m head, 4 star rated, suitable for operation normal voltage supply shall be 415 v ( or - )6 percent , 3 ph, 50 hz, bee rating: 4 star rated, nominal speed- 2900 rpm. head range-35-60 meter. discharge head range- 80-40 m3/h. discharge at 46 m head. nrv size-100 mm, 3 stage/4 stage or multistage. min3 well diameter-200 m.m, cable length-03 meter. the motor shall be totally enclosed copper wound squirrel cage induction t
For complete deion and other details, please refer to tender
Read moreVertical type submersible motor pump capacity-20hp/1375 lpm at 46m head or , 4 star rated, suitable for operation normal voltage supply shall be 415 v ( or - 6 percent ) , 3 phase, 50 hz, nominal speed- 2900 rpm. head range-35-60 m. discharge head range- 100-40 m3/h. nrv size-100 mm, 3 stage/4 stage or multistage. min3 well diameter-200 mm, cable length- 03 meter. the motor shall be totally enclosed copper wound squirrel cage induction type water cooled & water lubricated (water fil
For complete deion and other details, please refer to tender
Read moreCopper conductor welding cable (hofr covering) , cable size 50 sq.mm, rated current in amps at 60 percent duty cycle is 360a as per drg.no. conforiming to is: 9857:1990 with latest amendment
For complete deion and other details, please refer to tender
Read moreAluminum conductor welding cable with general purpose hofr compound covering with the following nominal area of conductor cable are at 60 percent duty cycle and 30 degree centigrade ambient temperature of the size 120 sq.mm, 522 amps conforming to ls: 9857/1990 (re-affirmed 1995) with amendment no.1/2007, technical specification: 1. type of cable and core: single core welding cable (flexible) 2. type of conductor: aluminum 3.cable size in square mm/rated current in amp at 60 percent duty cy
For complete deion and other details, please refer to tender
Read moreIsi marked cable flexi welding to welding cable size 50 sq. mm to is: 9857/1990 with general purpose hofr compound covered with copper conductor having nominal area of conductor 360 a at 60 percent duty cycle & 30 degree centigrade ambient temperature. makes: polycab/ finolex/ plaza/ r r cables/ mescab/ havells/ anchor. note: one sample metre should be got approved before effecting bulk supply.
For complete deion and other details, please refer to tender
Read moreWelding cable isi marked, copper conductor single core flexible hofr elastomeric compound covering nominal cross sectional area 95 sq. mm for 460 amps at 85 percent duty cycle conforming to is:9857/1990 or latest. make: prima, telgo, weecab,safewell or similar.
For complete deion and other details, please refer to tender
Read moreCopper conductor welding cable covered with hofr normal duty elastomeric compound (conforming to is: 9857/1990, reaffirmed-2020 , first revision, incorporating amendment no.01) with nominal area of conductor 70 sq.mm. , 454 ampere current rating at maximum duty cycle of 60 percent and ambient temperature 30 degree celsius.
For complete deion and other details, please refer to tender
Read moreof your Industry type