Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Zotarolimus Drug Eluting Coronary Stent System With Core Wire Technology Platinium Iridium Core Con
|
| Description |
|
| Organisation | Department of Military Affairs | Ministry of Defence |
| Tender Id | GEM/2024/B/4418699 |
|
Reference Number |
- |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link |
View Original Tender Notice
https://bidplus.gem.gov.in/all-bids |
| Start Date | January 06, 2024 14:58 |
| End Date |
Expired
27/01/2024
Expired 992 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Award of Contract & Bid Results
Technical Evaluation Results
| S.No. | Seller Name | Offered Item | Participated On | EMD Status | MSE/MII Status | Status |
|---|---|---|---|---|---|---|
| 1 | ANSH THERAPEUTICS PRIVATE LIMITED | Make : Model : Title : | 25-01-2024 12:51:32 | Registered with designated Agency / Authority | N/A | Evaluated |
| 2 | CONTINENTAL DRUG STORES | Make : Multimedics Model : M Sure Title : Sirolimus Eluting Stent Co Dess Cr Platform Having Microporus Surface With Sheallc Resin Topcoat And | 25-01-2024 17:57:14 | Registered with designated Agency / Authority | N/A | Evaluated |
| 3 | Evolution Health Science | Make : VEIVA SCIENTIFIC Model : REIVAS Title : Sirolimus Eluting Stent Co Dess Cr Platform Having Microporus Surface With Sheallc Resin Topcoat And | 25-01-2024 18:47:33 | Offline upload | N/A | Evaluated |
| 4 | M/S LIFELINE MEDICALS | Make : S3V Model : 3V Neil Title : Drug Eluting Stent | 26-01-2024 22:49:09 | Offline upload | N/A | Evaluated |
| 5 | NEXGEN ENTERPRISES | Make : ABBOTT (ST JUDE) Model : Aglis HisPro Title : Aglis HisPro | 25-01-2024 20:14:46 | Registered with designated Agency / Authority | N/A | Evaluated |
| 6 | Ria Pharmaceuticals And Surgicals | Make : Meril Life Sciences India Pvt. Limited Model : EVERMINE50 EVEROLIMUS STENT Title : EVERMINE50 EVEROLIMUS STENT | 25-01-2024 20:12:40 | Registered with designated Agency / Authority | N/A | Evaluated |
| 7 | SHAKUN DISTRIBUTORS | Make : INVENT BIOMED Model : NOVA VIDA Title : Sirolimus Eluting Stent Co dess Cr platform having microporus surface with sheallc resin topcoat an | 26-01-2024 18:14:31 | Registered with designated Agency / Authority | N/A | Evaluated |
| 8 | SUNRISE IMAGING SYSTEMS | Make : Sahajanand Medical Technologies Ltd Model : Tetrilimus Title : Tetrilimus | 25-01-2024 18:01:30 | Registered with designated Agency / Authority | N/A | Evaluated |
Vascular suture mediated closure and repair system sterile with 3 point 0 mono filamen polypropylene suture 300 series stainless steel needles,non complaint ballon,holter patches disposable nc 1340 web cardio 7 days er proof wireless multiday holter patch sp7,everolimus eluting balloon mounted platinum chromium coronary stent system assorted size,flexible lead free radiation shield,high pressure 3 port manifold,dedicated kit angiography for radial,coronary angioplasty kit,zotarolimus eluting balloon expandable cobalt alloy coronary stent system with continuous sinusoidal design assorted size,terumo angiography guide wire 0 point 035 x 150 cm j tip,hp laser toner cartridge for hp laser 103a
Vascular suture mediated closure and repair system sterile with 3 point 0 mono filamen polypropylene suture 300 series stainless steel needles,non complaint ballon,holter patches disposable nc 1340 web cardio 7 days er proof wireless multiday holter patch sp7,everolimus eluting balloon mounted platinum chromium coronary stent system assorted size,flexible lead free radiation shield,high pressure 3 port manifold,dedicated kit angiography for radial,coronary angioplasty kit,zotarolimus eluting balloon expandable cobalt alloy coronary stent system with continuous sinusoidal design assorted size,terumo angiography guide wire 0 point 035 x 150 cm j tip,hp laser toner cartridge for hp laser 103a
Read moreEverolimus drug eluting coronary stent on platinum chromium platform - bioabsorable with abluminal coating. additional connectors 4/5 in the proximal 2 segments. strut thickness 1.5 mm. available sizes 2.25 mm to 5.0 mm in diameter, 8.0 mm to 48 mm in length. 2 connector design throughout the body mecd >7.0 mm.
Everolimus drug eluting coronary stent on platinum chromium platform - bioabsorable with abluminal coating. additional connectors 4/5 in the proximal 2 segments. strut thickness 1.5 mm. available sizes 2.25 mm to 5.0 mm in diameter, 8.0 mm to 48 mm in length. 2 connector design throughout the body mecd >7.0 mm.
Read moreThe nitinol core coronary wire - width should be 0.014 in diameter and length of 180 cm or more. the tip weight should be less than one gram. should have hydrophilic coating. should have 1:1 torquability. should be compatible with dock extension wire
The nitinol core coronary wire - width should be 0.014 in diameter and length of 180 cm or more. the tip weight should be less than one gram. should have hydrophilic coating. should have 1:1 torquability. should be compatible with dock extension wire
Read moreZotarolimus drug eluting coronary stent system with core wire technology platinium iridium core con
Read more
Zotarolimus drug eluting coronary stent system with core wire technology platinium iridium core con
Read more
Zotarolimus drug eluting coronary stent system with core wire technology platinium iridium core con
Read more
Coronary stent zotarolimus eluting coronary platform with core wire technology,zotarolimus eluting
Read more
Coronary stent zotarolimus eluting coronary platform with core wire technology,zotarolimus eluting
Read more