Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Fire Retardant Low Tension Cotton Adhesive Tape For Electrical Purposes, Conforming To Icf S Specification No. Icf/Elec/921 Rev 0 With Cs 2, In Rolls Of 10 Mtrs Length, Thickness Of 0.30 Plus Or Minus 0.05 Mm And Width Of 20 Plus Or Minus 1.0 Mm. However, The Firms May Quote For Latest Specn./Drawing With Amendment If Any Issued By Rdso/Icf/Rcf. Note: Colours Red, Blue And Yellow In Equal Quantities Are Required.
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106561450 |
|
Reference Number |
41241074 |
| Tender Fee | 0 |
| EMD | 26400 |
| Tender Value | - |
| Place | Secunderabad |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/012025/106561450/viewNitPdf_4814351.pdf |
| Start Date | December 23, 2024 19:40 |
| End Date |
Expired
23/01/2025
Expired 630 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Electronic beam irradiated cross linked flexible cable of size 95 sq. mm black colour, voltage grade 1.8/3.0 kv as per rdso specification no. elrs/spec/elc/0019/ rev.4, of february 2018. however, the firms may quote for latest specification/drawing with amendment, if any, issued by rdso/icf/rcf/mcf etc.
Electronic beam irradiated cross linked flexible cable of size 95 sq. mm black colour, voltage grade 1.8/3.0 kv as per rdso specification no. elrs/spec/elc/0019/ rev.4, of february 2018. however, the firms may quote for latest specification/drawing with amendment, if any, issued by rdso/icf/rcf/mcf etc.
Read moreLed light fitting for passenger alarm chain indication type-i (3 w) conforming to rcf drg. no. lw76098 and rdso specification no. rdso/pe/spec/tl/0091-2016 (rev. 1), rcf annexure 1,2,3. however, the firms may quote for latest specn./drawing with amendment if any issued by rdso/icf/rcf/mcf etc.
Led light fitting for passenger alarm chain indication type-i (3 w) conforming to rcf drg. no. lw76098 and rdso specification no. rdso/pe/spec/tl/0091-2016 (rev. 1), rcf annexure 1,2,3. however, the firms may quote for latest specn./drawing with amendment if any issued by rdso/icf/rcf/mcf etc.
Read moreBelt tensioning device for 25kw brushless alternator conforming rdso/elec/dte/skel/3940 (sheet-i alt. 5 & sheet-ii alt.5) with modified spring conforming to rdso drg. no. rdso/pe/sk/ac/0068-2004 (rev-0). however, the firms may quote for latest specn./drawing with amendment if any issued by rdso/icf/rcf/mcf etc.
Belt tensioning device for 25kw brushless alternator conforming rdso/elec/dte/skel/3940 (sheet-i alt. 5 & sheet-ii alt.5) with modified spring conforming to rdso drg. no. rdso/pe/sk/ac/0068-2004 (rev-0). however, the firms may quote for latest specn./drawing with amendment if any issued by rdso/icf/rcf/mcf etc.
Read moreDiffuser for fluorescent light fitting to item no.7 of icf drg. no. sk-7-6-103 col. iii with alterations c to m. note: material for item no.7 should be lexan-940 polycarbonate grains of ge plastic only and shall be free from scratches, air bubbles and holes etc. insignia of the firm may be embossed on the diffuser. however, the firms may quote for latest specification/drawing with amendment if any issued by rdso/icf/rcf.
Diffuser for fluorescent light fitting to item no.7 of icf drg. no. sk-7-6-103 col. iii with alterations c to m. note: material for item no.7 should be lexan-940 polycarbonate grains of ge plastic only and shall be free from scratches, air bubbles and holes etc. insignia of the firm may be embossed on the diffuser. however, the firms may quote for latest specification/drawing with amendment if any issued by rdso/icf/rcf.
Read moreNylon 66 bush for suspension of 25 kw, of size dia70x dia 58x100 for 110 v dc brushless alternator conforming to item-1 of rdso drg. no. rdso/pe/sk/tl/0086-2014 (rev2) - alteration no.1 and material conforming to specn no. rdso/pe/spec/ac/0006- 2009 (rev.1). however, the firms may quote for latest specification/drawing with amendment if any issued by rdso/icf/rcf/mcf.
Nylon 66 bush for suspension of 25 kw, of size dia70x dia 58x100 for 110 v dc brushless alternator conforming to item-1 of rdso drg. no. rdso/pe/sk/tl/0086-2014 (rev2) - alteration no.1 and material conforming to specn no. rdso/pe/spec/ac/0006- 2009 (rev.1). however, the firms may quote for latest specification/drawing with amendment if any issued by rdso/icf/rcf/mcf.
Read moreBrushless dc railway carriage fan 225 mm sweep 110v dc bracket type complete as per rdso specification no. rdso/pe/spec/tl/0021-2005 rev.3 with amendment no. 1 with frp blade and crash worth guard. the guard shall be conforming to drg. no. icf/sk-7-6-158 coi-ii alt.g od of the fan guard 270mm plus minus 2 mm. dimension of fan shall conform to drawing rdso/pe/sk/tl/0026-2002 (rev 0 ) and complete fan will be silver ash colour
Brushless dc railway carriage fan 225 mm sweep 110v dc bracket type complete as per rdso specification no. rdso/pe/spec/tl/0021-2005 rev.3 with amendment no. 1 with frp blade and crash worth guard. the guard shall be conforming to drg. no. icf/sk-7-6-158 coi-ii alt.g od of the fan guard 270mm plus minus 2 mm. dimension of fan shall conform to drawing rdso/pe/sk/tl/0026-2002 (rev 0 ) and complete fan will be silver ash colour
Read moreBrass tubes (seamless) od 6mm plus minus 0.05, id 5mm plus minus 0.05 mm of two meter length to spe
Read more
Brass tubes (seamless) od 6mm plus minus 0.05, id 5mm plus minus 0.05 mm of two meter length to spe
Read more
Insulation tape with,fire retardant pre- [insulation tape with,fire retardant pre-coated cloth with fire retardant adhesive width 20 mm plus minus 1.00 mm thickness 0.3 plus minus 0.05 mm as per icf s specification no. icf/elec/921.cs 04 rev.0 with print rly-rly as per special condition clause no.8.5 of icf s specification.]
For complete deion and other details, please refer to tender
Read moreFrlt cotton insulation tape for electrical purpose width 20 mm , plus/minus 1.0 mm, thickness 0.30mm, plus/minus 0.05 mm, in 10 meter length roll conf. to icf specn. no. icf/elect/921 cs no. 1 rev. 0 inculding inflammability test with railway monogram printed in english and hindi on non adhesive back side.
For complete deion and other details, please refer to tender
Read moreof your Industry type