Work Of Attending Oil Leakage, Gasket Replacement, Transformer Oil Centrifuging Including Servicing/Overhauling Of Oltc Of 315 Mva T/F Ii At 400 Kv S/S Banda Under Electricity Transmission Circle Banda.
|
Description |
Work Of Attending Oil Leakage, Gasket Replacement, Transformer Oil Centrifuging Including Servicing/Overhauling Of Oltc Of 315 Mva T/F Ii At 400 Kv S/S Banda Under Electricity Transmission Circle Banda.
|
Organisation | UP Power Transmission Corp.Ltd (Operation) | State Govt. and UT |
Tender Id | 2025_UPTCL_991268_1 |
Reference Number |
T-17/ETC(B)/2024-25 |
Tender Fee | 590 |
EMD | 15000 |
Tender Value | |
Place | Banda |
Link | https://etender.up.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=1750895 |
Start Date | January 08, 2025 19:30 |
End Date |
17/01/2025 ( Expired 118 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Work of conducting the residual life assessment test of 100 mva, 220/132kv transformer-2 (bhel make) and 100 mva 220/132kv transformer ngef make (dismantled) at 220 kv s/s pahadi, chitrakoot under etd banda.
Work of conducting the residual life assessment test of 100 mva, 220/132kv transformer-2 (bhel make) and 100 mva 220/132kv transformer ngef make (dismantled) at 220 kv s/s pahadi, chitrakoot under etd banda.
Read moreSupply and refilling work of sf6 gas cylinder at various 400/220/132 kv sub station under electricity transmission circle banda.
Supply and refilling work of sf6 gas cylinder at various 400/220/132 kv sub station under electricity transmission circle banda.
Read moreFor repairing and servicing of ctr make n2 fire protection system installed on 100 mvar t/f ist areva make and 60 mva tf ii technical associate make at 220 kv sub station sikandrabad under etd bulandshahr
For repairing and servicing of ctr make n2 fire protection system installed on 100 mvar t/f ist areva make and 60 mva tf ii technical associate make at 220 kv sub station sikandrabad under etd bulandshahr
Read moreWork for internal inspection of 160 mva, 220/132/11 kv ict (emco make) transformer from outside agency at 220 kv s/s, azamgarh under electy. 400 kv s/s division, amamgarh
Work for internal inspection of 160 mva, 220/132/11 kv ict (emco make) transformer from outside agency at 220 kv s/s, azamgarh under electy. 400 kv s/s division, amamgarh.
Read moreWork of arresting oil leakage from various points of 40 mva transformer abb make at 132 kv sub station banda under etd banda.
Work of arresting oil leakage from various points of 40 mva transformer abb make at 132 kv sub station banda under etd banda.
Read moreAttending gas leakage 145 kv cb of 63 mva t/f i 132 kv shamshabad2 fatehabad line at 132 kv ss fatehabad
Attending gas leakage 145 kv cb of 63 mva t/f i 132 kv shamshabad2 fatehabad line at 132 kv ss fatehabad
Read moreWork for internal inspection of 160 mva, 220/132/11 kv ict (emco make) transformer from outside experience agency at 220 kv s/s, azamgarh under electy. 400 kv s/s division, amamgarh.
Work for internal inspection of 160 mva, 220/132/11 kv ict (emco make) transformer from outside experience agency at 220 kv s/s, azamgarh under electy. 400 kv s/s division, amamgarh.
Read moreWork for attending sf-6 gas leakage of 245 kv sf-6 circuit breaker a 400 kv s/s division-i muradnagar
Work for attending sf-6 gas leakage of 245 kv sf-6 circuit breaker a 400 kv s/s division-i muradnagar
Read moreWork of oil leakage from power transformers of 33/11 kv power s/s-karauthi (08 mva), sathala (05 mva), khadmohan nagar (10 mva) and maduna (05 mva) of subdivision-i, syana under edd-syana, bulandshahr.
Work of oil leakage from power transformers of 33/11 kv power s/s-karauthi (08 mva), sathala (05 mva), khadmohan nagar (10 mva) and maduna (05 mva) of subdivision-i, syana under edd-syana, bulandshahr.
Read morePrive maintenance of oltc servicing, filtration/dehydration of no 2 transformer 20 mva at 33/11 kv shekhwati grid in the area of age (sldc) e/s under ge (u) elect supply delhi cantt - 10
Prive maintenance of oltc servicing, filtration/dehydration of no 2 transformer 20 mva at 33/11 kv shekhwati grid in the area of age (sldc) e/s under ge (u) elect supply delhi cantt - 10