Integration Of Hooter To Tas For Complying Esa Recommendation At Bpcl Mci.
Description
As An Esa Observation, It Is Planned To Install New Hooters To Have A Separate Audio Visual Alarm For Dyke Drain Valve, Hc Ds Etc.To Configure These Hooters With The Existing Human Machine Interface (Hmi) We Must Perform Modification In Existing Tas To Integrate 5 Nos. Hooters Activation On Esd, Hhh, Dyke Drain Valve And Hcd. Scope Also Includes Necessary Changes In Safety Plc Logic And Scada To Accommodate The Hooter Status.View Above It Is Planned To Do The Integration Of Hooter To Scada At Bpcl Mci. Since The Tas Is Maintained By M/S Honeywell Automation India Limited, India, Who Is The Oem Of Scada System, It Is Proposed That This Work Be Carried Out By Honeywell. Therefore, It Is Recommended To Proceed With A Single Tender And Award This Job To Honeywell.
Organisation Bharat Petroleum Corporation Limited | Public Sector Undertakings
Tender Id 2025_BPCL_20325
Reference
Number
1000432947
Tender Fee 0
EMD 0
Tender Value -
Place Mangalore
Link
View Original Tender Notice

https://bpcltenders.eproc.in

Start Date March 08, 2025 21:00
End Date
Expired 13/03/2025

Expired 579 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Custom bid for services - supply and integration of 2 inch ethanol metering skid with existing bcu of tlf gantry at bpcl sidhpur top

Custom bid for services - supply and integration of 2 inch ethanol metering skid with existing bcu of tlf gantry at bpcl sidhpur top

Read more
Miscellaneous electrical works for esa audit observations at bpcl mci

One of the esa audit observations was that the static earthing should be provided at tlf gantry independently, for that electrical connections need to be done by laying earth strips from gantry to respective earth pits made nearby gantry area. also earthing of la need to do, by laying earth strips to the respective earth pits made nearby gantry area. next audit observation was that earthing needs to be provided for all the motors and push button stations of 4 ows in the plant. it involves laying, connecting earth strips to earth pits. other esa audit observation was to have separate audio-visual alarm for hcds and dyke drain valve, which includes installing hooters in each dyke by laying cables from the nearest jb to the hooter

Read more
Flp light fitting works for esa compliance and lux improvement at bpcl mci

2. as per oisd and pngrb norms, it must be properly illuminated. it was observed during last esa audit and monthly lux study that few areas like road around tlf gantry, tlf pump house manifold and road around tank farm are not as illuminated as it should be. hence it is proposed to strategically procure and place adequate no of flp light fittings and its accessories to always ensure adequate lux levels. 3. through this tender, we intend to procure, install, and re-organize flp light fittings for esa compliance and overall lux improvement at bpcl mci

Read more
Sitc of cfs tas integration panel at bpcl kanpur depot

Sitc of cfs tas integration panel at bpcl kanpur depot

Read more
Tender for tas integration of bio diesel tanks at bpcl irugur

Integration of all instruments to terminal automation system for new bio sel tanks at bpcl irugur

Read more
Integration of rosov with tas at bpcl bhatinda depot honeywell e&p

Integration of rosov with tas at bpcl bhatinda depot honeywell e&p

Read more
Mechanical & civil jobs for esa recommendation compliance

Oisd audit at mci was conducted from 20th august 2024 to 23rd august 2024. for compliance with major recommendations like standardizing of platforms of foam monitor, providing pcc and curb wall at pump house and mov area, providing additional foam monitor and mefg etc. we are floating this tender to registered vendors.

Read more
E-tender for integration of honeywell tas with iris interface at bpcl rasayani lpg plant

E-tender for integration of honeywell tas with iris interface at bpcl rasayani lpg plant

Read more
Miscellaneous electrical works at bpcl mci

Mci being a coastal location is receiving rainfall for more than 6 months per year. during the latest inspection of the earth pits, it was noted that the reading for some earth pits was significantly high and needs to be reconditioned. additionally, testing of the transformer oil is also pending. due to severe weather conditions, several flp and non-flp fittings need to be replaced. furthermore, during the recent servicing of the hvlr, it was observed that the hvlr cables and glands require both replacement and repairs. therefore, we propose to carry out these various electrical tasks.

Read more
Click Here to Download Dockets
of your Industry type
Get customized tender Recommendations for your Enterprise