🚂 Procurement Opportunity: Femoral Interlocking Nail 🦵🔧 The Ministry Of Railways, Specifically The Central Government Ministry/Department, Is Seeking Tenders For The Supply Of Femoral Interlocking Nails. 🏥 📍 Location: Kolkata 🗓️ Deadline: July 15, 2024, 1:30 Pm The Specifications For The Femoral Interlocking Nails Include: 1. Made Of Titanium, Available In Various Sizes And Diameters. 2. Each Nail Should Come With 4 Interlocking Bolts. 3. The Nail Must Be Sourced Through The Government Of Tamil Nadu (Gt) Procurement Channel. 4. The Shaft Of The Nail Must Feature Vertical, Symmetrical Grooves For Enhanced Rotational Stability. 5. The Diameter Of The Anterior Curvature Of The Nail Should Be 1 Mm To Prevent Anteriorolateral Impingement. 6. The Design Should Also Allow For The Ion Of A Hip Screw. Interested Suppliers Are Requested To Submit Detailed Tenders, Including All Necessary Documentation And Compliance With The Specified Requirements, By The Stipulated Deadline. Keywords: Femoral Interlocking Nail, Titanium, Interlocking Bolts, Rotational Stability, Hip Screw, Ministry Of Railways, Tender, Procurement| Particulars | Details |
|---|---|
| Title |
Femoral Interlocking Nail Specification 1. Femoral Interlocking Nail Made Of Titanium Of Different Sizes And Diameter Along With 4 Interlocking Bolts 2. Nail Ion Should Be Through Gt 3. There Should Be Vertical Symmetrical Grooves In The Shaft Of The Nail For Better Rotational Stability. 4. Provision For Ion Of Hip Screw Should Also Be There. 5. Diameter Of Anterior Curvature Of Nail Should Be 1 Mm To Pr Anterolateral Impingement
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106391426 |
|
Reference Number |
22245454 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Kolkata |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/072024/106391426/viewNitPdf_4622957.pdf |
| Start Date | June 28, 2024 15:59 |
| End Date |
Expired
15/07/2024
Expired 822 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
The nitinol core coronary wire - width should be 0.014 in diameter and length of 180 cm or more. the tip weight should be less than one gram. should have hydrophilic coating. should have 1:1 torquability. should be compatible with dock extension wire
The nitinol core coronary wire - width should be 0.014 in diameter and length of 180 cm or more. the tip weight should be less than one gram. should have hydrophilic coating. should have 1:1 torquability. should be compatible with dock extension wire
Read moreHumerus multilock nail set [srphc82414005-humerus multilock nail set should consist of reamed humerus nail with 4.5mm multilock blunt screws and 2 locking scrws. it should be available in diameter of 7,8,8.5,9.5mm with length ranging from 160 -300mm. itshould have polyethylene inlay with options of 3.5 and 4mm locking screws with complete set of instrumentation. unit:set]
Humerus multilock nail set [srphc82414005-humerus multilock nail set should consist of reamed humerus nail with 4.5mm multilock blunt screws and 2 locking scrws. it should be available in diameter of 7,8,8.5,9.5mm with length ranging from 160 -300mm. itshould have polyethylene inlay with options of 3.5 and 4mm locking screws with complete set of instrumentation. unit:set]
Read morePvc soft rubber tubing 8mm diameter, unsterile used for suction. should be 25 meter length in a single pack, pvc soft rubber tubing 6mm diameter, unsterile used for suction should be 180 meter length in a single pack
Pvc soft rubber tubing 8mm diameter, unsterile used for suction. should be 25 meter length in a single pack, pvc soft rubber tubing 6mm diameter, unsterile used for suction should be 180 meter length in a single pack
Read moreTrochanteric femur nail advanced system one set. spec: (1) 9 mm to 12 mm diameter with inbuilt set screw. (2) should be capable of allowing cannulated screw or blade (one) with same hole in proximal part. (3) end of blade and screw should be porous to allow augmentation with 5 mm distal locking option (two). (4) material should be titanium molybdenum. (complete range of size shape and side specific implant with instrumentation should be available at the time of surgery).[ item code no.:s6155
Trochanteric femur nail advanced system one set. spec: (1) 9 mm to 12 mm diameter with inbuilt set screw. (2) should be capable of allowing cannulated screw or blade (one) with same hole in proximal part. (3) end of blade and screw should be porous to allow augmentation with 5 mm distal locking option (two). (4) material should be titanium molybdenum. (complete range of size shape and side specific implant with instrumentation should be available at the time of surgery).[ item code no.:s6155
Read moreOuter glass for destination board of vande bharat as per icf drg.no. train 18/mc/ac-5-4-002, item no.01 as enclosed. note:- 1). solid black raster and fading black raster should be available as per drawing. 2). there should be toughened clear float glass in the led display area.
Outer glass for destination board of vande bharat as per icf drg.no. train 18/mc/ac-5-4-002, item no.01 as enclosed. note:- 1). solid black raster and fading black raster should be available as per drawing. 2). there should be toughened clear float glass in the led display area.
Read moreNeedle for inside-out meniscal repair with eye for thread.1. standard-length stainless steel with a 38cm or more in length and diameter should be 0.8 mm or less. 2. should be made up of high strength, flexible stainless steel, 3. needle should have eye on non-sharp end to pass minimum 2-0 suture. 4. needles can be used with other meniscal repair systems. (as per detailed specifications attached)
Needle for inside-out meniscal repair with eye for thread.1. standard-length stainless steel with a 38cm or more in length and diameter should be 0.8 mm or less. 2. should be made up of high strength, flexible stainless steel, 3. needle should have eye on non-sharp end to pass minimum 2-0 suture. 4. needles can be used with other meniscal repair systems. (as per detailed specifications attached)
Read moreTelescopic nail consists of male and female components.male component is solid one and available in varying lengths 4.2mm,(diameters from 120 to 280mm) and5.1mm ( diameters from 6mm to 280mm).female component is cannulated and available in varying lengths 5mm( diameter from120 to 280mm), and6.0mm(diameters from 160 to 300 mm).set should be supplied with all necessary instruments
Telescopic nail consists of male and female components.male component is solid one and available in varying lengths 4.2mm,(diameters from 120 to 280mm) and5.1mm ( diameters from 6mm to 280mm).female component is cannulated and available in varying lengths 5mm( diameter from120 to 280mm), and6.0mm(diameters from 160 to 300 mm).set should be supplied with all necessary instruments
Read more1) eus fine needle biopsy needle 22g/25g, 2) disposable flexible martin argon beamer system probe gastrointestinal track (git) straight fire probe should have diameter 2.3 mm and length 3.4m with ceramic tip for double balloon enteroscopy, 3) disposable flexible martin argon beamer system probe gastrointestinal track (git), side fire probe should have diameter 2.3 mm and length 2.3 m with ceramic tip, 4) disposable cholngioscope biliary biopsy forceps 1. forceps should be compatible with suita
1) eus fine needle biopsy needle 22g/25g, 2) disposable flexible martin argon beamer system probe gastrointestinal track (git) straight fire probe should have diameter 2.3 mm and length 3.4m with ceramic tip for double balloon enteroscopy, 3) disposable flexible martin argon beamer system probe gastrointestinal track (git), side fire probe should have diameter 2.3 mm and length 2.3 m with ceramic tip, 4) disposable cholngioscope biliary biopsy forceps 1. forceps should be compatible with suita
Read moreOne piece femoral adult arterial cannula. 1) it should have a micro-port tips, made of a one piece material and kink resistant 2) cannula length 17 inche(43.2 cm) overall length with 7.1 in(18 cm) tip it should offer a high flow rate with minimal pressure differntial. 3) cannula should have a introducer along with depth markings to precise the position of the cannulae.should be vented 3/8 in(0.95 cm) connector. size 19 fr biomedicus. cat no.96570 - 019.
One piece femoral adult arterial cannula. 1) it should have a micro-port tips, made of a one piece material and kink resistant 2) cannula length 17 inche(43.2 cm) overall length with 7.1 in(18 cm) tip it should offer a high flow rate with minimal pressure differntial. 3) cannula should have a introducer along with depth markings to precise the position of the cannulae.should be vented 3/8 in(0.95 cm) connector. size 19 fr biomedicus. cat no.96570 - 019.
Read moreAntibiotic impregnated knee cement spacer: temporary implantable spacer device for use in infected total knee arthroplasty, load bearing structure bone cement with gentamycin additive. in four different femoral and tibial sizes (small, medium, large, and extra large, respectively of 60,70,80, and 90mm tibial plateau dimensions).these should be available as and when required basis.
Antibiotic impregnated knee cement spacer: temporary implantable spacer device for use in infected total knee arthroplasty, load bearing structure bone cement with gentamycin additive. in four different femoral and tibial sizes (small, medium, large, and extra large, respectively of 60,70,80, and 90mm tibial plateau dimensions).these should be available as and when required basis.
Read moreof your Industry type