Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Contactor (With Diode), Rated Current 16 Amp, Rated Voltage 690 V Ac, Main Pole 3 No, Aux, Contact 1 Nc, Control Voltage 77 143 V Dc, With Surge Suppressor, As, Per Rdso Specification No., Rdso/Pe/Spec/Ac/0184 2015 (Rev.1) Suitable For Ventilation Fan, Condenser & Heater Of Rmpu Of Lhb Eog Ac, Coaches
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106542300 |
|
Reference Number |
96246572 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | New Delhi |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/122024/106542300/viewNitPdf_4792705.pdf |
| Start Date | December 02, 2024 23:07 |
| End Date |
Expired
12/12/2024
Expired 672 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
3 phase measuring and monitoring relay rated voltage looo v ac for net 1 net 2 as per rdso spcn. no. rdso/pe/spec/ac/0184-2015(rev.1)
3 phase measuring and monitoring relay rated voltage looo v ac for net 1 net 2 as per rdso spcn. no. rdso/pe/spec/ac/0184-2015(rev.1)
Read moreContactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest
Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest
Read moreMpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0)
Mpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0)
Read moreContactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,
Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,
Read moreContactor for net 1 & 2 rated voltage: 1 [contactor for net 1 & 2 rated voltage: 1000 v a. c, rated kva- 100 at rated voltage & 70 .
Contactor for net 1 & 2 rated voltage: 1 [contactor for net 1 & 2 rated voltage: 1000 v a. c, rated kva- 100 at rated voltage & 70 .
Read moreContactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21
Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21
Read moreFeeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)
Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)
Read moreFeeder contactor, current rating 200 amps, voltage rating 750v ac main pole: 4 nos., aux contact: 2no + 2nc, control voltage-380-415v ac with surge suppressor for net-1 & net -2 in sbcof lhb ac coaches confirming to item no. 57 & 58 of bom of rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-0). [ warranty period: 30 months after the date of delivery ]
Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole: 4 nos., aux contact: 2no + 2nc, control voltage-380-415v ac with surge suppressor for net-1 & net -2 in sbcof lhb ac coaches confirming to item no. 57 & 58 of bom of rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-0). [ warranty period: 30 months after the date of delivery ]
Read moreHrc fuse link (din type) 25amp, 415 /500v ac breaking cap 120ka, size 000,conf. to rdso specification no. rdso/pe/spec/ac/0184 - 2015 (rev-1).
Hrc fuse link (din type) 25amp, 415 /500v ac breaking cap 120ka, size 000,conf. to rdso specification no. rdso/pe/spec/ac/0184 - 2015 (rev-1).
Read moreof your Industry type