Tender Details
Particulars | Details |
---|---|
Title |
Contactor (With Diode) For Compressor Unit Cp 1.1, Cp 1.2, Cp 2.1 & Cp 2.2 Rated Current: 32 Ampere (At Rated Voltage & Ac 3 Utilization Category) Rated Voltage 690 V, Main Pole: 3 No Auxl. Contact: 1 Nc, Control Voltage: 110 V Dc / 15 Percent With Surge Suppressor Conforming To Rdso Specs No. Rdso/Pe/Spec/Ac/0184 2015 (Rev 1).
|
Description |
For Complete Deion And Other Details, Please Refer To Tender
|
Organisation | Ministry of Railways | Central Govt. Ministry/Department |
Tender Id | 106489720 |
Reference Number |
02241947 |
Tender Fee | 0 |
EMD | 1.82 Lakh |
Tender Value | |
Place | New Delhi |
Link | https://www.ireps.gov.in/ireps/supply/pdfdocs/102024/106489720/viewNitPdf_4733572.pdf |
Start Date | October 04, 2024 21:40 |
End Date |
29/10/2024 ( Expired 195 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
Dc to dc converter for switch board cabinet of lhb ac coaches-110/24 v,240w, 10a as per abb catalogue no: cp-c.1 24/10, phoenix catalogue no: trio-ps-2g/1ac/24dc/10-2903149, cosel catalogue no: klea240f-24, siemens catalogue no: 6ep13363ba10 and ask powertech catalogue no. ask-cs-24v, 10a as per rdso spec. no. rdso/pe/spec/ac/0184 2015 rev.1 & rdso lr.no. el/7.1.108/mssbc, dt 17/09/21.
For complete deion and other details, please refer to tender
Read moreFuse base for cylindrical low voltage hrc fuse of capacity 2 amps, 500v ac as per part no bmm603-iso of eaton bussman suitable for fuse of size 10x38 as per bill of material and confirming to rdso specd, no rdso/pe/spec/ac/0184-2015 (rev-1) latest for use in switch board cabinet of lhb type ac coaches make eaton bussman, siba, eti, l&t, siemens, abb, rbco
For complete deion and other details, please refer to tender
Read moreDc to dc converter for switch board cabinet of lhb ac coaches - 110/24 v, 1.5 a as per abb model no: cp-e 24/2.5, cosel powertech model no. lga50a-24sn(2.1a), phoenix model no. step-ps/1a/24dc/1.75, schneider model no.abl8rem24030, siemens model no. 6ep33216sb100ay0 as per the bill of material of rdso spec. no: rdso/pe/spec/ ac/ 0184 - 2015 (rev-1) and rdso lr.no. el/7.1.108/mssbc, dt 17/09/21.
For complete deion and other details, please refer to tender
Read moreMotor protection circuit breaket (mpcb) of rated current 1-1.6 amp with 2 nos aux contacts (1no1nc aux contact block), thermal range 1-1.6 amp, class-10, breaking capacity-50ka, 3pole, rated voltage 690vac, confirming to rdso modification sheet no. rdso/pe/ms/tl/0090-2023 (rev-0). rdso approved make & cat no.:- abb cat no. ms116-1.6, hk1-11, schneider cat no. gv2-me06gv-ae11, siemens cat no. 3rv20111aa103rv2901-1e, and l&t cat no. st418940000st419450000.
For complete deion and other details, please refer to tender
Read moreMpcb for ventilation fan unit 1 & 2, thermal release range (rated current) 2.5 - 4 a, class 10, breaking capacity 50ka, pole 3p, rated voltage 415v ac, 1 no 1 nc auxilary contact block confirming to rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-0).
For complete deion and other details, please refer to tender
Read moreContactor for 60 kva transformer rated current: 95a, rated voltage: 690v ac, main pole: 4, auxiliary contact: 1 no1 nc, control voltage: 230v ac (168v ac-300v ac means 230v ac /- 30 percent ) with surge suppressor. as per sr.no.36 of d common bom of rdso no. el/7.1.108/mssbc dt-17.09.2021, makes are abb (cat. no. af 116 b-40), schneider (cat. no. lc1d1150046m5la4da2u), siemens (cat. no. 3rt2346-1np30-4aa0) or l&t (cat. no. mcx 23) only acceptable.
For complete deion and other details, please refer to tender
Read more3-pole mcb, rated current: 16a, curve: d , voltage 415v ac, breaking capacity: 10 ka of make: l&t of model no. bb30160d or siemens of model no. 5sl73168rc or abb of model no. sb203 m-d16 or schneider of model no. a9n3p16d or legrand of model no. 408762. conforming bom of rdso specification no. rdso/pe/spec/ac/0192-2018 (rev.1)
For complete deion and other details, please refer to tender
Read moreMulti function three phase monitoring relay, automatic phase sequences correction and separate monitoring of over and under voltage, rated control supply, voltage 3 phase,1000v ac for net 1 and net 2 as per rdso spec. no. rdso/pe/spec/ac/0184 2015 rev.1 & rdso lr.no. el/7.1.108/mssbc, dt 17/09/21 to carlo gavazzi model no. dpc01dm1kb001 or dold model no. bd-9080-12/003 or abb model no. cm-mpn.72s or l&t model no. smb110 and phoenix.
For complete deion and other details, please refer to tender
Read moreContactor with surge suppressor and aux contact suitable for lhb ac coaches current rating 95 amps voltage
For complete deion and other details, please refer to tender
Read more3 kvar metalized polypropylene gas filled, wavy cut three phase self healing type capacitors, rated at 480v, 50hz , rated current 3.6 amps capacitor should have discharge resistor and over pressure disconnection as per rdso modification sheet no. rdso/pe/ms/ac/0054-2014 rev-0 and confirming to is: 13340(part-1) : 2012/iec 60832-1:2002 with isi mark suitable for capacitor bank of lhb ac coach. acceptable makes: epcos or vishay or any other equivalent capacitor confirming to is:13340 with isi ma
For complete deion and other details, please refer to tender
Read moreof your Industry type