Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Bbc Contact Complete (Aux Cam Switch) As Per Cl Ws
Drg.No:4 Twd.101.138 Etc.
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106456829 |
|
Reference Number |
02241139 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Bhubaneswar |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/092024/106456829/viewNitPdf_4708497.pdf |
| Start Date | September 09, 2024 18:22 |
| End Date |
Expired
30/09/2024
Expired 745 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Aux. contact support assembly with 6 aux. switch as per clw drg. no.4twd 112.090, alt.-5, (sheet no.0)
Aux. contact support assembly with 6 aux. switch as per clw drg. no.4twd 112.090, alt.-5, (sheet no.0)
Read moreAuxiliary switch assembly for ctf, j & mp as per clw drawing no. 4twd.101.138, alt.-6 outer sheet and specification no. 4tes.111.028 alt-1.
Auxiliary switch assembly for ctf, j & mp as per clw drawing no. 4twd.101.138, alt.-6 outer sheet and specification no. 4tes.111.028 alt-1.
Read moreSet of modified fixed contact & mobile contact complete for ep contactor type tcp 3421-25-2m & 3469-24-3m specification :- clw drg.no- (1) 3twd.112.010a alt.4 (2) 3twd.112.116a alt 4 (specification copy is attached)
Set of modified fixed contact & mobile contact complete for ep contactor type tcp 3421-25-2m & 3469-24-3m specification :- clw drg.no- (1) 3twd.112.010a alt.4 (2) 3twd.112.116a alt 4 (specification copy is attached)
Read moreBearing for contact roller complete for tap changer specification/drg. :- bt drg.no-ag-546150 p1, bt pt. no- s 1514, aal drg no.-9910383541001, aal, pt.no.-g1514
Bearing for contact roller complete for tap changer specification/drg. :- bt drg.no-ag-546150 p1, bt pt. no- s 1514, aal drg no.-9910383541001, aal, pt.no.-g1514
Read moreAuxiliary switch and lever assembly for em contactor having two aux. contact switch [one switch having 2 nc, 01 no. and other switch having 1nc, 02 no. contacts] as per clw drawing no. 2twd.291.053 alt-3, 3twd.291.049 alt-1, 3twd.291.057 alt.1 and specn.no. 4tts.291.002 alt-2
Auxiliary switch and lever assembly for em contactor having two aux. contact switch [one switch having 2 nc, 01 no. and other switch having 1nc, 02 no. contacts] as per clw drawing no. 2twd.291.053 alt-3, 3twd.291.049 alt-1, 3twd.291.057 alt.1 and specn.no. 4tts.291.002 alt-2
Read moreFixed contact cb 100b1 part no cb100b1,moving contact part no cb100b2,moving contact carrier part no cb100b3,copper bralded wire from moving contact part no cb100b9,insulator fixed contact bar part no cb100b10,insulator moving contact bar cb 100b 11 part no cb100b11,trip bar assly cb 100b 12 part no cb100b12,like gear part no cb100b13,meg o l dash pot type cb 100c 2 part no cb100c2,e l relay unit complete type cb 1 part no cb100c3,sensitive earth leakage relay upto 750ma part no cb100c3ma,control fuse holder cb 100c 4 part no cb100c4,test microswitch part no cb100c5,regestance part no cb100c6,micro switch for e l lamp cb 100c 7 part no cb100c7,cb100c 9 bridg rctfr part no cb100c9,isolator moving contact acb 100amps type part no cb100d1a,isolator fixed contact flapper part no cb100d1b,sensetive cbt for e l relay 750 ma part no cb100d2ma,current transformer for overload part no cb100d3,current transformer for ammeter part no cb100d3a,ammeter100 5 acb 100amps cb 84 part no cb100d4,e l lamp holder with lamp cb 10
Fixed contact cb 100b1 part no cb100b1,moving contact part no cb100b2,moving contact carrier part no cb100b3,copper bralded wire from moving contact part no cb100b9,insulator fixed contact bar part no cb100b10,insulator moving contact bar cb 100b 11 part no cb100b11,trip bar assly cb 100b 12 part no cb100b12,like gear part no cb100b13,meg o l dash pot type cb 100c 2 part no cb100c2,e l relay unit complete type cb 1 part no cb100c3,sensitive earth leakage relay upto 750ma part no cb100c3ma,control fuse holder cb 100c 4 part no cb100c4,test microswitch part no cb100c5,regestance part no cb100c6,micro switch for e l lamp cb 100c 7 part no cb100c7,cb100c 9 bridg rctfr part no cb100c9,isolator moving contact acb 100amps type part no cb100d1a,isolator fixed contact flapper part no cb100d1b,sensetive cbt for e l relay 750 ma part no cb100d2ma,current transformer for overload part no cb100d3,current transformer for ammeter part no cb100d3a,ammeter100 5 acb 100amps cb 84 part no cb100d4,e l lamp holder with lamp cb 10
Read morePower contactor [with diode] for compressor unit of lhb type ac coaches, 3 pole, rated current- 32 a (at rated voltage & ac-3 utilization category), rated voltage- 690 v, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, conforming to rdso spec no. rdso / pe / spec / ac / 0184-2015 (rev1), suitable for lhb type ac coaches switch board cabinet [place of intallation- s1k33, s1k34, s1k38, s1k39]. accepted make & cat nos.: - as per sr. no. 60 of common bom of rdso letter no. e
Power contactor [with diode] for compressor unit of lhb type ac coaches, 3 pole, rated current- 32 a (at rated voltage & ac-3 utilization category), rated voltage- 690 v, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, conforming to rdso spec no. rdso / pe / spec / ac / 0184-2015 (rev1), suitable for lhb type ac coaches switch board cabinet [place of intallation- s1k33, s1k34, s1k38, s1k39]. accepted make & cat nos.: - as per sr. no. 60 of common bom of rdso letter no. e
Read moreVcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Read moreBbc aux. cam switch, clw drg.no.3twd
For complete deion and other details, please refer to tender
Read moreof your Industry type