Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Single I Suspension String (Pilot) For 400k V Ac With Quad Acsr Moose Conductor,Single" I" Suspensio
|
| Description |
|
| Organisation | POWER GRID Corporation OF INDIA Limited | Ministry of Power |
| Tender Id | GEM/2023/B/4193569 |
|
Reference Number |
- |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link |
View Original Tender Notice
https://gem.gov.in/ |
| Start Date | November 15, 2023 23:17 |
| End Date |
Expired
06/12/2023
Expired 1047 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Award of Contract & Bid Results
Technical Evaluation Results
| S.No. | Seller Name | Offered Item | Participated On | EMD Status | MSE/MII Status | Status |
|---|---|---|---|---|---|---|
| 1 | AUMNI TRANSMISSION INDUSTRY PVT. LTD. | Make : ATIPL Model : ATIPL Title : Transmission Line Hardware & Accessories upto 400KV | 06-12-2023 17:12:41 | Registered with designated Agency / Authority | MII MSE | Qualified |
| 2 | LEGION ENERGY PRODUCTS PRIVATE LIMITED | Make : LEGION ENERGY PRODUCTS PRIVATE LIMITED Model : LEGION ENERGY PRODUCTS PVT LTD Title : Single I Suspension Pilot String For 400kV Quad ACSR Moose Conductor With 200 KG Counter Weigh | 06-12-2023 11:04:43 | Offline upload | MII | Qualified |
| 3 | NIKE ENERGY MANUFACTURING PRIVATE LIMITED | Make : Nike Energy Manufacturing Pvt. Ltd. Model : NE/HW/971 Title : Single" I" Suspension String (Pilot) for 400kV AC for Quad Moose | 25-12-2023 17:47:34 | Registered with designated Agency / Authority | MII MSE | Qualified |
10 sqmm multistrand single core frls,1 quad solid conductor frls,1 quad solid conductor zhls,24f single mode armoured ofc zhls,2 quad solid conductor zhls,8c solid conductor zhls,10 sqmm multistrand single core zhls,12c solid conductor zhls
10 sqmm multistrand single core frls,1 quad solid conductor frls,1 quad solid conductor zhls,24f single mode armoured ofc zhls,2 quad solid conductor zhls,8c solid conductor zhls,10 sqmm multistrand single core zhls,12c solid conductor zhls
Read moreReplacement of 220 kv main bus bar from single tarantulla conductor to acsr twin moose conductor and other related work at 220 kv ss boner under etd-i aligarh
Replacement of 220 kv main bus bar from single tarantulla conductor to acsr twin moose conductor and other related work at 220 kv ss boner under etd-i aligarh
Read more400kv dc quad moose garautha-talbehat line ac interference study through software modelling and simulation in bina-panki bpcl pipeline under etc jhansi
400kv dc quad moose garautha-talbehat line ac interference study through software modelling and simulation in bina-panki bpcl pipeline under etc jhansi
Read moreTggenco - nshes - design, manufacture, testing at manufacturers works, inspection, packing, supply of acsr moose conductor at nshes, nagarjuna sagar.
Tggenco - nshes - design, manufacture, testing at manufacturers works, inspection, packing, supply of acsr moose conductor at nshes, nagarjuna sagar.
Read moreSc210190462 765kv connector suitable for gt for quad acsr bersimis,sc210190469 765kv through type connector suitable for la for quad acsr bersimis,sc210190468 765kv through type connector suitable for bpi for quad acsr bersimis,sc210190463 765kv flexible type spacers for quad acsr bersimis conductor with 450mm scs,sc210190464 765kv rigid type spacers for quad acsr bersimis conductor with 450mm scs,sc210190465 765kv tee connector for quad acsr bersimis to quad acsr bersmis,sc210190470 765kv pg clamp for acsr bersimis to acsr bersimis,sc210190467 132kv connector suitable for st for twin acsr zebra with 250mm scs,sc210190461 132kv through type connector suitable for la for twin acsr zebra with 250mm scs,sc210190466 132kv through type connector suitable for bpi for twin acsr zebra with 250mm scs,sc210190471 132kv flexible type spacers for twin acsr zebra with 250mm scs,sc210190473 132kv rigid type spacer for twin acsr zebra with 250mm scs,sc210190474 132kv tee connector for twin acsr zebra to twin acsr zebra,sc21
Sc210190462 765kv connector suitable for gt for quad acsr bersimis,sc210190469 765kv through type connector suitable for la for quad acsr bersimis,sc210190468 765kv through type connector suitable for bpi for quad acsr bersimis,sc210190463 765kv flexible type spacers for quad acsr bersimis conductor with 450mm scs,sc210190464 765kv rigid type spacers for quad acsr bersimis conductor with 450mm scs,sc210190465 765kv tee connector for quad acsr bersimis to quad acsr bersmis,sc210190470 765kv pg clamp for acsr bersimis to acsr bersimis,sc210190467 132kv connector suitable for st for twin acsr zebra with 250mm scs,sc210190461 132kv through type connector suitable for la for twin acsr zebra with 250mm scs,sc210190466 132kv through type connector suitable for bpi for twin acsr zebra with 250mm scs,sc210190471 132kv flexible type spacers for twin acsr zebra with 250mm scs,sc210190473 132kv rigid type spacer for twin acsr zebra with 250mm scs,sc210190474 132kv tee connector for twin acsr zebra to twin acsr zebra,sc21
Read moreTransmission line package- tl01 for design, engineering and construction of dedicated 400kv d/c transmission line with twin moose acsr conductor from potheadyard of ratle hep to kishtwar pooling station along with associated communication equipment
Transmission line package- tl01 for design, engineering and construction of dedicated 400kv d/c transmission line with twin moose acsr conductor from potheadyard of ratle hep to kishtwar pooling station along with associated communication equipment.
Read more66 kv isolators with out earthing blade 1250 amp,acsr panther conductor,66 kv disc insulators 120 kn,66 kv suspension fitting for panther conductor,66 kv tension fittings for panther conductor
66 kv isolators with out earthing blade 1250 amp,acsr panther conductor,66 kv disc insulators 120 kn,66 kv suspension fitting for panther conductor,66 kv tension fittings for panther conductor
Read moreRe-conductoring and strengthening of the 132 kv mawlai to sohra single circuit transmission line and 132 kv nehu to lad nongkrem to mustem to khliehriat sub-station by acsr panther conductor and related services (line length 101.452ckm)
Re-conductoring and strengthening of the 132 kv mawlai to sohra single circuit transmission line and 132 kv nehu to lad nongkrem to mustem to khliehriat sub-station by acsr panther conductor and related services (line length 101.452ckm)
Read moreof your Industry type