Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Repairing And Renovation Of Capacitor Bank And Its 11 Kv, 800 Amps Yule Make(vcb) Breaker Panel At Dugda Coal Washery Sub Station.
|
| Description |
Repairing And Renovation Of Capacitor Bank And Its 11 Kv, 800 Amps Yule Make(vcb) Breaker Panel At Dugda Coal Washery Sub Station.
|
| Organisation | Bharat Coking Coal Limited | Public Sector Undertakings |
| Tender Id | 2025_BCCL_325957_1 |
|
Reference Number |
DCW/Ele(41)2024-25/114 |
| Tender Fee | 0 |
| EMD | 2617 |
| Tender Value | - |
| Place | Dugda Coal washery |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=337866 |
| Start Date | January 17, 2025 15:30 |
| End Date |
Expired
22/01/2025
Expired 629 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Maintenance and reconditioning of 2 nos. vcb (11kv and 6.6kv, pce make), 2 nos. ocb switch (11kv, 800 amp, gec make), sf6 abb make breaker (33kv, 1250 amp), maintenance of ct, and repairing of 11kv capacitor bank control panel at central substation
Maintenance and reconditioning of 2 nos. vcb (11kv and 6.6kv, pce make), 2 nos. ocb switch (11kv, 800 amp, gec make), sf6 abb make breaker (33kv, 1250 amp), maintenance of ct, and repairing of 11kv capacitor bank control panel at central substation
Read moreComplete repairing, overhauling of 6.6kv, 1250 amps ngef make ps-24, ps-9, ps-8 and loading section low oil circuit breaker with its panel in loading section at madhuban coal washery under block-ii area, bccl.
Complete repairing, overhauling of 6.6kv, 1250 amps ngef make ps-24, ps-9, ps-8 and loading section low oil circuit breaker with its panel in loading section at madhuban coal washery under block-ii area, bccl.
Read moreBifurcation of the existing 11kv dnm colony feeder emanating from 33/11kv lodha indoor ss by using existing idle 11kv capacitor bank breaker and laying of 0.5 km 11kv 3x300 sqmm xlpe ug cable (double run) in sanathnagar section of sanathnagar subdivision in greenlands division and the work will be executed by the construction wing of banjara hills circle
Bifurcation of the existing 11kv dnm colony feeder emanating from 33/11kv lodha indoor ss by using existing idle 11kv capacitor bank breaker and laying of 0.5 km 11kv 3x300 sqmm xlpe ug cable (double run) in sanathnagar section of sanathnagar subdivision in greenlands division and the work will be executed by the construction wing of banjara hills circle
Read moreVcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Read moreRepairing and renovation of capacitor bank and its 11 kv, 800 amps yule make(vcb) breaker panel at dugda coal washery sub-station.
Repairing and renovation of capacitor bank and its 11 kv, 800 amps yule make(vcb) breaker panel at dugda coal washery sub-station.
Read moreRepairing of andrew yule and co. make 11 kv, vcb, 630 amps, ctr-100-200/5 amps for capacitor bank of controlling switch gear at 11k/33kv sub-station, nlocp/dbocp.
Repairing of andrew yule and co. make 11 kv, vcb, 630 amps, ctr-100-200/5 amps for capacitor bank of controlling switch gear at 11k/33kv sub-station, nlocp/dbocp.
Read moreRepairing of 02 nos.,800 amps, 02 nos.1200 amps and 02 nos. 2500 amps, 440v air circuit breaker at moonidih coal washery.
Repairing of 02 nos.,800 amps, 02 nos.1200 amps and 02 nos. 2500 amps, 440v air circuit breaker at moonidih coal washery.
Read moreof your Industry type