1000005351 Pt, Remote Seal, Hart, Range: 0 35 Kg/Cm2, Diaphragm Hastelloy C 276, Flange Rating 1.5 300# ,,1000009905 Dpt, Remote Seal, Hart, Range: 0 10000 Mmwc, Diaphragm Ss316 L, Flange Rating 1.5 300# , As Per,1000005346 Pt, Standard, Hart, Range: 0 10 Kg/Cm2, Diaphragm Ss316 L, As Per Data Sheet Mrpl/Inst/Pt/008,1000005345 Pt, Standard, Hart, Range: 0 20 Kg/Cm2, Diaphragm Ss316 L, As Per Data Sheet Mrpl/Inst/Pt/012.
Description
1000005351 Pt, Remote Seal, Hart, Range: 0 35 Kg/Cm2, Diaphragm Hastelloy C 276, Flange Rating 1.5 300# ,,1000009905 Dpt, Remote Seal, Hart, Range: 0 10000 Mmwc, Diaphragm Ss316 L, Flange Rating 1.5 300# , As Per,1000005346 Pt, Standard, Hart, Range: 0 10 Kg/Cm2, Diaphragm Ss316 L, As Per Data Sheet Mrpl/Inst/Pt/008,1000005345 Pt, Standard, Hart, Range: 0 20 Kg/Cm2, Diaphragm Ss316 L, As Per Data Sheet Mrpl/Inst/Pt/012.
Organisation Mangalore Refinery & Petrochemicals Limited | Materials Department
Tender Id Login to view
Reference
Number
Login to view
Tender Fee -
EMD -
Tender Value -
Place
Link Login to view
Start Date October 14, 2026 22:46
End Date
Open 04/11/2026

17 days left

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Pressure gauge (oil medium range: 0-400 kg/cm2) as per attached specifications in annexure# 1

Pressure gauge (oil medium range: 0-400 kg/cm2) as per attached specifications in annexure# 1

Read more
8 upvc pipe ( 6.0 kg/cm2 rating) , ( sch no. 40) , 6 meter per length as per annexure attached

8 upvc pipe ( 6.0 kg/cm2 rating) , ( sch no. 40) , 6 meter per length as per annexure attached

Read more
Master pressure gauge with dial range 0-16 kg/cm2, dial size: 8 , least count:0.05 kgs/cm2, lower mount connection. accuracy: +/-0.25 percent of fsd accuracy. accepted make:midlands or similar . note:nabl certificate required during supplies

Master pressure gauge with dial range 0-16 kg/cm2, dial size: 8 , least count:0.05 kgs/cm2, lower mount connection. accuracy: +/-0.25 percent of fsd accuracy. accepted make:midlands or similar . note:nabl certificate required during supplies

Read more
63210-ft-318 and 319 mod. hx-1and2 flow-dpt, calibration, range- 0 - 500 inch wc, make- fuji, model- fyc835vk-aahcg-ee-0,67131-dpt-13043 and 13044 mod. hx-1and2 p.w. diff. pressure-dpt-, calibration, range- 0-787.8 inch wc, make- fuji, model- fyc836vk-aahcg-ee-0,63496-lt-7 d2o transfer tank level -dpt, alibration, range - 8.2-40.9 inch wc, make- fuji, model- fyc833vk-aahcg-ee-0,3210-lt-12 he circuit tank level-dpr-, calibration, range - 0-33 inch wc, make- fuji, model- fyc833vk-aahcg-ee-0,63250-lt-41 mod. l.c. level -dpt-, calibration,range - 0-77.5 inch wc, make- fuji, model- fyc833vk-aahcg-ee-0,63241-ft-328, 329 cal. spray flow 1 and 2 -dpt, calibration, range 0 - 260 inch wc, make- fuji, model- fyc835vk-aahcg-ee-0,663210-pt-32 mod. pump suction pressure-absolute pressure transmitter-pt, calibration, range - 0.7-2.0, kg per cm2, make- fuji, model- fyg802vk-aahcg-ee-0,6320-pt-21,14103 dump tank level transmitter-dpt-, calibration, range-0-151.6 inch wc, make - fuji, model- fyc835vk-aahcg-ee-0

63210-ft-318 and 319 mod. hx-1and2 flow-dpt, calibration, range- 0 - 500 inch wc, make- fuji, model- fyc835vk-aahcg-ee-0,67131-dpt-13043 and 13044 mod. hx-1and2 p.w. diff. pressure-dpt-, calibration, range- 0-787.8 inch wc, make- fuji, model- fyc836vk-aahcg-ee-0,63496-lt-7 d2o transfer tank level -dpt, alibration, range - 8.2-40.9 inch wc, make- fuji, model- fyc833vk-aahcg-ee-0,3210-lt-12 he circuit tank level-dpr-, calibration, range - 0-33 inch wc, make- fuji, model- fyc833vk-aahcg-ee-0,63250-lt-41 mod. l.c. level -dpt-, calibration,range - 0-77.5 inch wc, make- fuji, model- fyc833vk-aahcg-ee-0,63241-ft-328, 329 cal. spray flow 1 and 2 -dpt, calibration, range 0 - 260 inch wc, make- fuji, model- fyc835vk-aahcg-ee-0,663210-pt-32 mod. pump suction pressure-absolute pressure transmitter-pt, calibration, range - 0.7-2.0, kg per cm2, make- fuji, model- fyg802vk-aahcg-ee-0,6320-pt-21,14103 dump tank level transmitter-dpt-, calibration, range-0-151.6 inch wc, make - fuji, model- fyc835vk-aahcg-ee-0

Read more
Oil pressure gauge for qph relay range- 0-2.5 kg/sq. cm & psi 1/2 bsp bottom type .

Oil pressure gauge for qph relay range- 0-2.5 kg/sq. cm & psi 1/2 bsp bottom type .

Read more
Isi marked single stage lpg regulator kit consisting of regulator with connector & pressure guage (0-2.5 kg/cm2) conforming to spec is: 6901-2009 amendment no.1.

Isi marked single stage lpg regulator kit consisting of regulator with connector & pressure guage (0-2.5 kg/cm2) conforming to spec is: 6901-2009 amendment no.1.

Read more
Mpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0)

Mpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0)

Read more
Vibration probe p n 1x35667 im,bearing rtd 700 kw 11 kv ht motor,diff pressure gauge range 0 16 kg sqcm,level switch for water tank,pressure gauge range 0 30 psig dial siz,hydro electric pressure switch,0 150 degree temperature gauge,vibration transmitter bn 3300,probe bn 3300 series,isolation transformer ir comp,signal isolator passive ir comp,temp transmitter 0 150deg,pressure transmitter range 0 1000 psi,press transmitter o 4000psi

Vibration probe p n 1x35667 im,bearing rtd 700 kw 11 kv ht motor,diff pressure gauge range 0 16 kg sqcm,level switch for water tank,pressure gauge range 0 30 psig dial siz,hydro electric pressure switch,0 150 degree temperature gauge,vibration transmitter bn 3300,probe bn 3300 series,isolation transformer ir comp,signal isolator passive ir comp,temp transmitter 0 150deg,pressure transmitter range 0 1000 psi,press transmitter o 4000psi

Read more
Operation and guarding of gaseous chlorination arrangement of capacity 0-1 kg/cm2 at zone-iii,part-a and part-b ohr ,zone-v, part-a and part-b ohr site under jda w/s scheme, in the dist. of alipurduar.

Operation and guarding of gaseous chlorination arrangement of capacity 0-1 kg/cm2 at zone-iii,part-a and part-b ohr ,zone-v, part-a and part-b ohr site under jda w/s scheme, in the dist. of alipurduar.

Read more
Digital gauss meter, having following specification: - ranges full-scale : 0 to 2 and 0 to 20 kilo gauss accuracy :+/- 1 percent full scale + one digit on the 2 k gauss range. : +/- 2 percent full scale + one digit on the 20 k gauss range resolution :0.1 percent of full scale. visual display :3.5 digit panel meter power : 240v a.c. 50 hz., 10 watts. size & weight : 210 mm x 95 mm x 225 mm and 1 kg approx. with hall probe,handheld battery-operated having lcd. calibration certificate from oem

Digital gauss meter, having following specification: - ranges full-scale : 0 to 2 and 0 to 20 kilo gauss accuracy :+/- 1 percent full scale + one digit on the 2 k gauss range. : +/- 2 percent full scale + one digit on the 20 k gauss range resolution :0.1 percent of full scale. visual display :3.5 digit panel meter power : 240v a.c. 50 hz., 10 watts. size & weight : 210 mm x 95 mm x 225 mm and 1 kg approx. with hall probe,handheld battery-operated having lcd. calibration certificate from oem

Read more