Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Tender For Supply Installation Testing And Commissioning Of 100 A Static Transfer Switches With Free Standing Enclosure For Dism Server Room At Isro Head Quarters, Antariksh Bhavan, Bangalore
|
| Description |
Tender For Supply Installation Testing And Commissioning Of 100 A
Static Transfer Switches With Free Standing Enclosure For Dism Server
Room At Isro Head Quarters, Antariksh Bhavan, Bangalore
|
| Organisation | Indian Space Research Organisation | Central Govt. Ministry/Department |
| Tender Id | 2025_ISRO_788491_1 |
|
Reference Number |
ISRO HQ/ISRO HQ PURCHASE/HQ202400011601 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | ISRO Headquarters, Bangalore |
| Link |
View Original Tender Notice
https://eprocure.gov.in/epublish/app?page=FrontEndTenderDetailsExternal&service=page&tnid=1092857 |
| Start Date | February 11, 2025 21:05 |
| End Date |
Expired
24/02/2025
Expired 600 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Sitc of two (2) nos. ups output distribution boards and two (2) nos. static transfer switches
Sitc of two (2) nos. ups output distribution boards and two (2) nos. static transfer switches
Read moreStatic transfer switches as per annexure-a - 7140994354,static transfer switches as per annexure-b
Read more
Static transfer switches or automatic transfer switches,network rack, 4u or 6u size,8mm square copp
Read more
Static transfer switches or automatic transfer switches,network rack, 4u or 6u size,8mm square copp
Read more
N plus1 modular type 10 kva ups,static transfer switch with 24u rack with power strip,surge protection devices class b plus c or type 1 plus 2,surge protection devices class c or type,client station cpu with 55 inch or bigger led,client pc with 23 inch monitor along with other accessories,ups cms server each with 23 inch display,ups cms software for and client position,isolation transformer,fire resistant cable multi strand 03 core 6 sq mm,type b curve double pole mcbs 32 amp,type b curve double pole mcbs 63 amp,wall mounted polycarbonate enclosure with transparent door,metallic square channel minimum 3 inches wide,stainless steel flexible conduits minimum 1point5 inches wide,heavy duty copper lugs or thimbles as per power cables,metallic cable glands as per outer diameter of power cables,single core multistrand 6 sq mm copper cable,cost of installation integration testing and commissioning of complete system
N plus1 modular type 10 kva ups,static transfer switch with 24u rack with power strip,surge protection devices class b plus c or type 1 plus 2,surge protection devices class c or type,client station cpu with 55 inch or bigger led,client pc with 23 inch monitor along with other accessories,ups cms server each with 23 inch display,ups cms software for and client position,isolation transformer,fire resistant cable multi strand 03 core 6 sq mm,type b curve double pole mcbs 32 amp,type b curve double pole mcbs 63 amp,wall mounted polycarbonate enclosure with transparent door,metallic square channel minimum 3 inches wide,stainless steel flexible conduits minimum 1point5 inches wide,heavy duty copper lugs or thimbles as per power cables,metallic cable glands as per outer diameter of power cables,single core multistrand 6 sq mm copper cable,cost of installation integration testing and commissioning of complete system
Read moreof your Industry type