Repairing / Replacement Of Damaged Lt / Ht Bushing With Stud And Gasket Of (A) 800 Kva Lighting Transformer, 3.3 Kv / 415 Volt, Sl. No. 398/1 Installed At Type Ii And Type Iii Colony And (B) 1250 Kva Lighting Transformer, 3.3 Kv / 415 Volt, Sl. No. Bs171
Description
Repairing / Replacement Of Damaged Lt / Ht Bushing With Stud And Gasket Of (A) 800 Kva Lighting Transformer, 3.3 Kv / 415 Volt, Sl. No. 398/1 Installed At Type Ii And Type Iii Colony And (B) 1250 Kva Lighting Transformer, 3.3 Kv / 415 Volt, Sl. No. Bs171
Organisation Central Coalfields Limited | Public Sector Undertakings
Tender Id 2024_CCL_320987_1
Reference
Number
SGW/KTA/ENM/E-Tender/24-25/72 Date 12.11.2024
Tender Fee 0
EMD 3000
Tender Value -
Place Office of the Project Officer, Sawang Washery
Link
View Original Tender Notice

https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=332733

Start Date November 13, 2024 16:30
End Date
Expired 23/11/2024

Expired 695 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Complete rewinding and repairing of primary and secondary breaker of andrew yule make 315 kva 3.3kv-550v sl no sspay03 transwitch transformer at shyamsundarpur colliery

Complete rewinding and repairing of primary and secondary breaker of andrew yule make 315 kva 3.3kv-550v sl no sspay03 transwitch transformer at shyamsundarpur colliery

Read more
Repairing and rewinding of 1mva 11kv/3.3kv power transformer sl. no. jrd/trf/1mva/01 installed at new sub-station of jarangdih colliery under kathara area.

Repairing and rewinding of 1mva 11kv/3.3kv power transformer sl. no. jrd/trf/1mva/01 installed at new sub-station of jarangdih colliery under kathara area.

Read more
Taking down of step up and down transformer 160kva after dismentling ht lt,gasket 6 mm thick superior quality on top cover plate,lt porcelain bushing with brass stud screwed with brass nuts bolts,ht 11 kv porcelain bushing with brass stud screwed with brass nuts,painting of transformer of rating 160 kva and voltage stabilizer with two coat,supply filling and top up with new transformer oil of electric strength,filtration dehydration of transformer oil of three phase servo voltage,rewinding of transformer 160 kva complete using appropriate size of copper,shifting of transformer from work shop to af stn including connecting,material and labour for arrange temporary power supply through comercial,trimming of tree branches to clear the ht lt oh lines girth span

Taking down of step up and down transformer 160kva after dismentling ht lt,gasket 6 mm thick superior quality on top cover plate,lt porcelain bushing with brass stud screwed with brass nuts bolts,ht 11 kv porcelain bushing with brass stud screwed with brass nuts,painting of transformer of rating 160 kva and voltage stabilizer with two coat,supply filling and top up with new transformer oil of electric strength,filtration dehydration of transformer oil of three phase servo voltage,rewinding of transformer 160 kva complete using appropriate size of copper,shifting of transformer from work shop to af stn including connecting,material and labour for arrange temporary power supply through comercial,trimming of tree branches to clear the ht lt oh lines girth span

Read more
Earth leakage relay -110v rating elm8,moving contact,fixed contact,plug insulator with tube set,brass terminal with insulator dmc,power contactor 525v, 3p, 110a,coil 110v, operating,bushing insulator with stud,potential transformer 550-525-415v,0-8-12-24,110v,3p,core balance transformer,isolator 300 amps reversing,cable1.1kv,2c, copper, pvc, 1.5 mm2 flexible

Earth leakage relay -110v rating elm8,moving contact,fixed contact,plug insulator with tube set,brass terminal with insulator dmc,power contactor 525v, 3p, 110a,coil 110v, operating,bushing insulator with stud,potential transformer 550-525-415v,0-8-12-24,110v,3p,core balance transformer,isolator 300 amps reversing,cable1.1kv,2c, copper, pvc, 1.5 mm2 flexible

Read more
Complete repairing and rewinding of 11kv 400v, 500kva, 3 phase lighting transformer, make ngef, sl. no. 28.0002.2206, for providing domestic power supply to sector 6, matigarha dam site under block-ii area.

Complete repairing and rewinding of 11kv 400v, 500kva, 3 phase lighting transformer, make ngef, sl. no. 28.0002.2206, for providing domestic power supply to sector 6, matigarha dam site under block-ii area.

Read more
3point3kv isolator on off earth reverse 400a part no kire,ammeter part no am,current transformer 60by5 15va part no 12060515,earth leakage relay 50 750 ma with time part no elm7lats,ht power fuse 3point3kv grade upto 100a part no hrc100,vacuum contactor 3point3kv part no bev006133,sensitive earth leakage relay 50 300ma w part no elm7stwpt,insulator support for ht pt fuse part no bs45,terminal bushing part no oba,aux contactor with coil part no boca2dn1229,busbar part no bbr300,brass cone and gland assembly part no bobcg,overload relay magnetic part no olr3,potential transformer 3point3kv 500va part no htptl1,ht bushing with stud 3point3 kv part no htta33

3point3kv isolator on off earth reverse 400a part no kire,ammeter part no am,current transformer 60by5 15va part no 12060515,earth leakage relay 50 750 ma with time part no elm7lats,ht power fuse 3point3kv grade upto 100a part no hrc100,vacuum contactor 3point3kv part no bev006133,sensitive earth leakage relay 50 300ma w part no elm7stwpt,insulator support for ht pt fuse part no bs45,terminal bushing part no oba,aux contactor with coil part no boca2dn1229,busbar part no bbr300,brass cone and gland assembly part no bobcg,overload relay magnetic part no olr3,potential transformer 3point3kv 500va part no htptl1,ht bushing with stud 3point3 kv part no htta33

Read more
Complete set of hotel load bushing (meta [complete set of hotel load bushing (metal part & insulator only) for 7775kva main transformer of wap7 locomotives as per clw spec no: - clw/es/3/0660 rev-d. a set consist of 07 items in 11 nos. (1) copper stud qty. 01 no. (2) brass nut qty. 03 nos (3) brass bush qty. 01 no. (4) brass flat washer qty. 02 nos. (5) brass taper washer qty. 01 no. (6) ms spring washer qty. 01 no. (7) top and bottom insulator qty. 02 nos. (material to be procured from clw-ap

Complete set of hotel load bushing (meta [complete set of hotel load bushing (metal part & insulator only) for 7775kva main transformer of wap7 locomotives as per clw spec no: - clw/es/3/0660 rev-d. a set consist of 07 items in 11 nos. (1) copper stud qty. 01 no. (2) brass nut qty. 03 nos (3) brass bush qty. 01 no. (4) brass flat washer qty. 02 nos. (5) brass taper washer qty. 01 no. (6) ms spring washer qty. 01 no. (7) top and bottom insulator qty. 02 nos. (material to be procured from clw-ap

Read more
Facility management service- manpower based (version 2) - education o&m of electrical work highly-skilled,facility management service- manpower based (version 2) - education o&m of electrical work highly-skilled,facility management service- manpower based (version 2) - education o&m of electrical work skilled,facility management service- manpower based (version 2) - education o&m of electrical work skilled,facility management service- manpower based (version 2) - education o&m of electrical work skilled,facility management service- manpower based (version 2) - education o&m of electrical work unskilled,customized amc/cmc for pre-owned products - 1250kva distribution transformer ht kirloskar annual maintenance contract (amc) annually no,customized amc/cmc for pre-owned products - vacuum circuit breaker (vcb) 11kv cgl annual maintenance contract (amc) annually no,customized amc/cmc for pre-owned products - air circuit breaker (acb) lt 415volt l&t annual maintenance contract (amc) annually

Facility management service- manpower based (version 2) - education o&m of electrical work highly-skilled,facility management service- manpower based (version 2) - education o&m of electrical work highly-skilled,facility management service- manpower based (version 2) - education o&m of electrical work skilled,facility management service- manpower based (version 2) - education o&m of electrical work skilled,facility management service- manpower based (version 2) - education o&m of electrical work skilled,facility management service- manpower based (version 2) - education o&m of electrical work unskilled,customized amc/cmc for pre-owned products - 1250kva distribution transformer ht kirloskar annual maintenance contract (amc) annually no,customized amc/cmc for pre-owned products - vacuum circuit breaker (vcb) 11kv cgl annual maintenance contract (amc) annually no,customized amc/cmc for pre-owned products - air circuit breaker (acb) lt 415volt l&t annual maintenance contract (amc) annually

Read more
Repairing / replacement of damaged lt / ht bushing with stud and gasket of (a) 800 kva lighting transformer, 3.3kv / 415volt, sl. no. 398/1 installed at type ii and type iii colony and (b) 120kva lighting transformer, 3.3kv / 415volt, sl. no. bs171-1

Repairing / replacement of damaged lt / ht bushing with stud and gasket of (a) 800 kva lighting transformer, 3.3kv / 415volt, sl. no. 398/1 installed at type ii and type iii colony and (b) 120kva lighting transformer, 3.3kv / 415volt, sl. no. bs171-1

Read more
Partial repairing of 1250kva, 3.3kv/440v transformer make ngef, sl. no. 2800040713 and 40 kva, 6.6kv/220v transformer make kirloskar, sl. no. 88ac008/11 by replacement of bushing with stud and corksheet under kdh ocp, nk area

Partial repairing of 1250kva, 3.3kv/440v transformer make ngef, sl. no. 2800040713 and 40 kva, 6.6kv/220v transformer make kirloskar, sl. no. 88ac008/11 by replacement of bushing with stud and corksheet under kdh ocp, nk area

Read more
Click Here to Download Dockets
of your Industry type
Get customized tender Recommendations for your Enterprise