Tender Details

Particulars Details
Title
Procurement Of Siemens Make Lv Swgr For Gt Cooler Control Cubicle For
Description
Procurement Of Siemens Make Lv Swgr For Gt Cooler Control Cubicle Fornorth Karanpura
Organisation NTPC Limited | Public Sector Undertakings
Tender Id 2024_NTPC_87607_1
Reference
Number
NTPC/USSC-CPG3/9900281988
Tender Fee 0
EMD 0
Tender Value -
Place NTPC North Karanpura
Link
View Original Tender Notice

https://eprocurentpc.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=90795

Start Date June 08, 2024 16:35
End Date
Expired 13/06/2024

Expired 854 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Procurement of air cooler air compressor spares and abb make lv switchgear spares under emiph i and ii. sgtpp

Procurement of air cooler air compressor spares and abb make lv switchgear spares under emiph i and ii. sgtpp

Read more
Set of complete control cubicle sb1 & sb2 along with all equipments and cabling (excluding control electronics) as per clw specifications no. clw/es/3/0194 alt j and clw/es/3/0195 alt j

Set of complete control cubicle sb1 & sb2 along with all equipments and cabling (excluding control electronics) as per clw specifications no. clw/es/3/0194 alt j and clw/es/3/0195 alt j

Read more
Contactor air break 415vac 70a 3p ml4,contactor air break 415ac 240 300a ml12,contactor 415vac mnx18 l and t pmcc or mccs,contactor 240v 50hz mnx32 l and t msbp lv,contactor 415vac mnx110 l and t pmcc or mccs,contactor 415vac mnx400 l and t pmcc or mccs,relay overload mn2 0 45 to 0 75a l and t,relay mn2 0 9 to 1 5 a l and t msbp lv,relay mn2 1 4 to 2 3a l and t msbp lv,relay mn5 14 to 23a l and t msbp lv,relay 20 to 33a mn5 l and t msbp lv,relay mn2 2 0 to 3 3a mn cont lt msbp lv,relay 30 to 50a mn5 lt msbp lv,relay mn2 3 to 5a lt msbp lv,relay mn2 4 5 to 7 5a l t msbp lv,relay 45 to 75a mn5 l t msbp,relay mn2 6 to 10a l t msbp lv,rly thermal o or l 66 to 110a mn 5 ss94137,relay mn2 9 to 15a l t msbp lv,fuselink hf 4a cylindrical l t msbp lv,fuselink hf 6a cylindrical l t msbp lv,fuselink hf 10a cylindrical l t msbp lv,fuselink hf 16a cylindrical l t msbp lv,fuse control 32a hf type cylindrica pdpp,fuse link hrc 63a lan0040159 l t cps,fuse lv hrc hn 415v 50hz 80a l t sf9402,fuse hrc din 100a hn size 000 bc pd

Contactor air break 415vac 70a 3p ml4,contactor air break 415ac 240 300a ml12,contactor 415vac mnx18 l and t pmcc or mccs,contactor 240v 50hz mnx32 l and t msbp lv,contactor 415vac mnx110 l and t pmcc or mccs,contactor 415vac mnx400 l and t pmcc or mccs,relay overload mn2 0 45 to 0 75a l and t,relay mn2 0 9 to 1 5 a l and t msbp lv,relay mn2 1 4 to 2 3a l and t msbp lv,relay mn5 14 to 23a l and t msbp lv,relay 20 to 33a mn5 l and t msbp lv,relay mn2 2 0 to 3 3a mn cont lt msbp lv,relay 30 to 50a mn5 lt msbp lv,relay mn2 3 to 5a lt msbp lv,relay mn2 4 5 to 7 5a l t msbp lv,relay 45 to 75a mn5 l t msbp,relay mn2 6 to 10a l t msbp lv,rly thermal o or l 66 to 110a mn 5 ss94137,relay mn2 9 to 15a l t msbp lv,fuselink hf 4a cylindrical l t msbp lv,fuselink hf 6a cylindrical l t msbp lv,fuselink hf 10a cylindrical l t msbp lv,fuselink hf 16a cylindrical l t msbp lv,fuse control 32a hf type cylindrica pdpp,fuse link hrc 63a lan0040159 l t cps,fuse lv hrc hn 415v 50hz 80a l t sf9402,fuse hrc din 100a hn size 000 bc pd

Read more
Supply and installation of 80 lit. water cooler with plate form and safety cover at vikas khand chaubepur gt road near prakash nursing home distt kanpur nagar bilhaur vidhan sabha

Supply and installation of 80 lit. water cooler with plate form and safety cover at vikas khand chaubepur gt road near prakash nursing home distt kanpur nagar bilhaur vidhan sabha

Read more
Retrofitting, testing and commissioning of abb make 12kv,1250a, 40ka, ht breakers with cradle solution in place of jyothi make ht breaker at control room swgr and old ht breaker of stacker/reclaimer-3 at chp-1 rtps

Retrofitting, testing and commissioning of abb make 12kv,1250a, 40ka, ht breakers with cradle solution in place of jyothi make ht breaker at control room swgr and old ht breaker of stacker/reclaimer-3 at chp-1 rtps

Read more
Repair, maintenance, and installation of plant/ systems/equipments (version 2) - bidder premices troubleshooting of siemens simatic panel and carrier chiller control card for icp service provider

Repair, maintenance, and installation of plant/ systems/equipments (version 2) - bidder premices troubleshooting of siemens simatic panel and carrier chiller control card for icp service provider

Read more
Customized amc/cmc for pre-owned products - amc for hmt make st 20 cnc lathe machine having siemence 840 d cnc control system for a period of 3 years hmt annual maintenance contract (amc) six-monthly no,customized amc/cmc for pre-owned products - amc for hmt make sbcnc 30/1000 cnc turn mill center having siemens 840 d cnc control system for a period of 3 years hmt annual maintenance contract (amc) six-monthly no,customized amc/cmc for pre-owned products - amc for takisawa make ts-20 cnc lathe machine having siemens 828 d cnc control system for a period of 3 years takisawa annual maintenance contract (amc) six-monthly no

Customized amc/cmc for pre-owned products - amc for hmt make st 20 cnc lathe machine having siemence 840 d cnc control system for a period of 3 years hmt annual maintenance contract (amc) six-monthly no,customized amc/cmc for pre-owned products - amc for hmt make sbcnc 30/1000 cnc turn mill center having siemens 840 d cnc control system for a period of 3 years hmt annual maintenance contract (amc) six-monthly no,customized amc/cmc for pre-owned products - amc for takisawa make ts-20 cnc lathe machine having siemens 828 d cnc control system for a period of 3 years takisawa annual maintenance contract (amc) six-monthly no

Read more
810182air intake setcode65324718,810183motor550wcode65322847,810184fan220 x 98code65321779,810185air conveyorcode65320640,810186fan scoopcode65320624,810187adaptersiemens agq3 1a27code65113521,810212control box base siemens code 65320092,810188control boxsiemens lme22 331c2code65324042,810189ignition transformercofi 1020cmcode65323223,810190remote control switchbg0910acode65323138,810191motor thermal relaylovato rf9 142 3a 2v3code65323098,810192main switchcod 40100i1509code65323064,810193gas light oil selectorcode65323067,810196timer basefinder cod 85 04 8 240code65324212,810198ignition cabletlcode65320942,810214rear disc 65320729,810215front disc 65320798,810216gasket 65321115,810203air damper motorsiemens sqn 30 151a2700code65322897,810204oil pumpsuntec at2v45a ccode63525121,810213coupling code 65322920,810205nippletn10x1200code65323188,810206hosestn 10x1200code65323187,810207pumpmotor75wcode65322782,810208condensator35 as per technical specification,810210 protectioncode 65324049,810217gasmultibloc gas val

810182air intake setcode65324718,810183motor550wcode65322847,810184fan220 x 98code65321779,810185air conveyorcode65320640,810186fan scoopcode65320624,810187adaptersiemens agq3 1a27code65113521,810212control box base siemens code 65320092,810188control boxsiemens lme22 331c2code65324042,810189ignition transformercofi 1020cmcode65323223,810190remote control switchbg0910acode65323138,810191motor thermal relaylovato rf9 142 3a 2v3code65323098,810192main switchcod 40100i1509code65323064,810193gas light oil selectorcode65323067,810196timer basefinder cod 85 04 8 240code65324212,810198ignition cabletlcode65320942,810214rear disc 65320729,810215front disc 65320798,810216gasket 65321115,810203air damper motorsiemens sqn 30 151a2700code65322897,810204oil pumpsuntec at2v45a ccode63525121,810213coupling code 65322920,810205nippletn10x1200code65323188,810206hosestn 10x1200code65323187,810207pumpmotor75wcode65322782,810208condensator35 as per technical specification,810210 protectioncode 65324049,810217gasmultibloc gas val

Read more
Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest

Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest

Read more
Feeder contactor net 1 & 2 for lhb non ac coaches, voltage rating 750 v ac, main pole 04 no, aux contact 2no + 2nc, control voltage 110 v ac with surge suppressor, abb cat no. af 50-40-00 + ca5-22e + rv5/250 or similar. make abb/schneider/siemens/l&t only as per rcf specification no. edts 355, rev -1.[i] this is non-restricted item as per suggested by tech deptt vide eoffice 362994[ii] description/spec taken accordingly above eoffice.[iii] 02 sources name taken as previous supplier.[iv] hrt de

Feeder contactor net 1 & 2 for lhb non ac coaches, voltage rating 750 v ac, main pole 04 no, aux contact 2no + 2nc, control voltage 110 v ac with surge suppressor, abb cat no. af 50-40-00 + ca5-22e + rv5/250 or similar. make abb/schneider/siemens/l&t only as per rcf specification no. edts 355, rev -1.[i] this is non-restricted item as per suggested by tech deptt vide eoffice 362994[ii] description/spec taken accordingly above eoffice.[iii] 02 sources name taken as previous supplier.[iv] hrt de

Read more
Click Here to Download Dockets
of your Industry type
Get customized tender Recommendations for your Enterprise