Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Replacement Of Bare Conductor Of 11 Kv Engineer Enclave Feeder By 11 Kv Aaac Insulated Covered Conductor Al 59, 99 Sqmm On 33/11 Kv Substation Niranjanpur, Dehradun.
|
| Description |
Replacement Of Bare Conductor Of 11 Kv Engineer Enclave Feeder By 11 Kv Aaac Insulated Covered Conductor Al 59, 99 Sqmm On 33/11 Kv Substation Niranjanpur, Dehradun.
|
| Organisation | MD - UPCL | State Govt. and UT |
| Tender Id | 2024_UPCL4_78886_1 |
|
Reference Number |
Tender No. 42/EDC(U)/2024-25 |
| Tender Fee | 11800 |
| EMD | 3.41 Lakh |
| Tender Value | - |
| Place | as per tender specification |
| Link |
View Original Tender Notice
https://uktenders.gov.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=94130 |
| Start Date | December 21, 2024 22:30 |
| End Date |
Expired
07/01/2025
Expired 645 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
3.3 kv, 3 core, 95 sqmm aluminium conductor pvc, dwa cable
3.3 kv, 3 core, 95 sqmm aluminium conductor pvc, dwa cable
Read moreWork for 11 kv bare conductor into covered conductor for simhasth 2028 at various location under city west division ujjain in sstd simhastha 2028 scheme
Work for 11 kv bare conductor into covered conductor for simhasth 2028 at various location under city west division ujjain in sstd simhastha 2028 scheme
Read moreWork for 11 kv bare converted into covered conductor for simhasth 2028 at various location city west division ujjain under sstd simhastha 2028 scheme
Work for 11 kv bare converted into covered conductor for simhasth 2028 at various location city west division ujjain under sstd simhastha 2028 scheme
Read moreWork for 11 kv bare conductor to covered conductor in green belt area for reliability of supply during the simhastha under kiosk zone city east division ujjain under sstd simhastha 2028 scheme
Work for 11 kv bare conductor to covered conductor in green belt area for reliability of supply during the simhastha under kiosk zone city east division ujjain under sstd simhastha 2028 scheme
Read moreAttending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Attending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Read moreAttending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Attending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Read moreSitc of free standing, outdoor cubicle type microprocessor based amf panel 15 kva,supplying, laying and fixing of al power cable in pipe,supplying, laying and fixing of al power cable on surface of wall,supplying, laying and fixing of al power cable in masonry open duct,supplying and making end termination with brass compression gland,supplying, laying and fixing of 8 c 1.5sq.mm pvc flexible cable,supplying and laying of 2 x 6 sq mm pvc insulated,supplying, laying of 16 sqmm size frls pvc insulated copper conductor,supplying and laying of industrial telephone cables,supplying and laying of dwc hdpe pipe,supplying and fixing of medium class pvc conduit,supplying and fixing of spn db,replacement of 12v, stop solenoid,llop sensor,hct hwt sensor,sensor float,dismantling of the existing dg control panel,rerouting of the existing cable
Sitc of free standing, outdoor cubicle type microprocessor based amf panel 15 kva,supplying, laying and fixing of al power cable in pipe,supplying, laying and fixing of al power cable on surface of wall,supplying, laying and fixing of al power cable in masonry open duct,supplying and making end termination with brass compression gland,supplying, laying and fixing of 8 c 1.5sq.mm pvc flexible cable,supplying and laying of 2 x 6 sq mm pvc insulated,supplying, laying of 16 sqmm size frls pvc insulated copper conductor,supplying and laying of industrial telephone cables,supplying and laying of dwc hdpe pipe,supplying and fixing of medium class pvc conduit,supplying and fixing of spn db,replacement of 12v, stop solenoid,llop sensor,hct hwt sensor,sensor float,dismantling of the existing dg control panel,rerouting of the existing cable
Read moreSitc of free standing, outdoor cubicle type microprocessor based amf panel 15 kva,sitc of free standing, outdoor cubicle type microprocessor based amf panel for 30 kva,supplying, laying and fixing of al power cable in pipe,supplying, laying and fixing of al power cable on surface of wall,supplying, laying and fixing of al power cable in masonry open duct,supplying and making end termination with brass compression gland,supplying, laying and fixing of 8 c 1.5sq.mm pvc flexible cable,supplying and laying of 2 x 1.5sq mm pvc insulated,supplying, laying of 16 sqmm size frls pvc insulated copper conductor,supplying and laying of industrial telephone cables,supplying and laying of dwc hdpe pipe,supply and fixing the steel wire reinforced flexible upvc conduit,supplying and fixing of spn db,supplying and fixing of medium class pvc conduit,replacement of 12v, stop solenoid,replacement of 24v, stop solenoid,llop sensor,hct hwt sensor,sensor float,start stop relay,12 v or 24v oen pla relay,sf 40 mm dia gi pipe,dismantl
Sitc of free standing, outdoor cubicle type microprocessor based amf panel 15 kva,sitc of free standing, outdoor cubicle type microprocessor based amf panel for 30 kva,supplying, laying and fixing of al power cable in pipe,supplying, laying and fixing of al power cable on surface of wall,supplying, laying and fixing of al power cable in masonry open duct,supplying and making end termination with brass compression gland,supplying, laying and fixing of 8 c 1.5sq.mm pvc flexible cable,supplying and laying of 2 x 1.5sq mm pvc insulated,supplying, laying of 16 sqmm size frls pvc insulated copper conductor,supplying and laying of industrial telephone cables,supplying and laying of dwc hdpe pipe,supply and fixing the steel wire reinforced flexible upvc conduit,supplying and fixing of spn db,supplying and fixing of medium class pvc conduit,replacement of 12v, stop solenoid,replacement of 24v, stop solenoid,llop sensor,hct hwt sensor,sensor float,start stop relay,12 v or 24v oen pla relay,sf 40 mm dia gi pipe,dismantl
Read moreLed tube light (retrofit type),led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3),led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3),xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1),xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1),pvc insulated copper cable single core and multi core circular sheathed with rigid conductor (v2) isi marked to is 694,led batten light (led tube light) (v2),miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1),led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3),xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1),xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1),mcb tpn four pole 100 amp 10 ka,refrigerent gas for ac plant r-32,service wire aluminium 2x 10 sqmm pvc,pcb for inverter ac,compressor rotary 2 tr r-
Led tube light (retrofit type),led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3),led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3),xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1),xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1),pvc insulated copper cable single core and multi core circular sheathed with rigid conductor (v2) isi marked to is 694,led batten light (led tube light) (v2),miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1),led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3),xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1),xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1),mcb tpn four pole 100 amp 10 ka,refrigerent gas for ac plant r-32,service wire aluminium 2x 10 sqmm pvc,pcb for inverter ac,compressor rotary 2 tr r-
Read moreReplacement of bare conductor of 11 kv sabji mandi feeder by 11 kv aaac insulated covered conductor al 59, 99 sqmm on 33/11 kv substation niranjanpur, dehradun.
Replacement of bare conductor of 11 kv sabji mandi feeder by 11 kv aaac insulated covered conductor al 59, 99 sqmm on 33/11 kv substation niranjanpur, dehradun.
Read moreof your Industry type