Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Digital Gauss Meter, Having Following Specification: Ranges Full Scale : 0 To 2 And 0 To 20 Kilo Gauss Accuracy :+/ 1 Percent Full Scale + One Digit On The 2 K Gauss Range. : +/ 2 Percent Full Scale + One Digit On The 20 K Gauss Range Resolution :0.1 Percent Of Full Scale. Visual Display :3.5 Digit Panel Meter Power : 240 V A.C. 50 Hz., 10 Watts. Size & Weight : 210 Mm X 95 Mm X 225 Mm And 1 Kg Approx. With Hall Probe,Handheld Battery Operated Having Lcd. Calibration Certificate From Oem
|
| Description |
Digital Gauss Meter, Having Following Specification: Ranges Full Scale : 0 To 2 And 0 To 20 Kilo Gauss Accuracy :+/ 1 Percent Full Scale + One Digit On The 2 K Gauss Range. : +/ 2 Percent Full Scale + One Digit On The 20 K Gauss Range Resolution :0.1 Percent Of Full Scale. Visual Display :3.5 Digit Panel Meter Power : 240 V A.C. 50 Hz., 10 Watts. Size & Weight : 210 Mm X 95 Mm X 225 Mm And 1 Kg Approx. With Hall Probe,Handheld Battery Operated Having Lcd. Calibration Certificate From Oem
|
| Organisation | Ministry of Railways |
| Tender Id | Login to view |
|
Reference Number |
Login to view |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link | Login to view |
| Start Date | October 15, 2026 21:51 |
| End Date |
Open
09/11/2026
23 days left |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Ac high voltage breakdown tester,power: [ac high voltage breakdown tester,power: 230v ac, 50 hz voltage range: 0 to 5 kv ac leakage current range: 0 to 100 ma test voltage range settable by knob of variac. trip current settable by press to set switch and potentiometer on ma meter. metering: 3 1/2 digit digital kv meter, ma meter accuracy: kv: 2 percent of reading +/- 3 digit, ma: 1.5 percent +/- 2 digit resolution: 0.1kv, 0.1ma respectively programmable timer: range: 0 to 999 seconds indicat
Ac high voltage breakdown tester,power: [ac high voltage breakdown tester,power: 230v ac, 50 hz voltage range: 0 to 5 kv ac leakage current range: 0 to 100 ma test voltage range settable by knob of variac. trip current settable by press to set switch and potentiometer on ma meter. metering: 3 1/2 digit digital kv meter, ma meter accuracy: kv: 2 percent of reading +/- 3 digit, ma: 1.5 percent +/- 2 digit resolution: 0.1kv, 0.1ma respectively programmable timer: range: 0 to 999 seconds indicat
Read moreMicro ohm meter with resistance range from 2 milli ohm to 20 kilo ohm
Micro ohm meter with resistance range from 2 milli ohm to 20 kilo ohm
Read moreDigital micro ohm meter with range 1 micro ohms to 19.99 k ohms having following specifications: (i) range: 8 full scale ranges of 0 - 1999 micro ohms/ 19.99 milli ohms/ 199.9 milli ohms/ 1999 milli ohms/ 19.99 ohms/ 199.9 ohms/ 1999 ohms/ 19.99 k ohms. (ii) accuracy :plus or minus 0.2 percent . plus or minus 2 least counts in all ranges except plus or minus 0.5 percent plus or minus 3 least counts in 200 milli ohms, 20 milli ohms and 2000 micro ohms ranges. (iii) input : 230v single phase ac
Digital micro ohm meter with range 1 micro ohms to 19.99 k ohms having following specifications: (i) range: 8 full scale ranges of 0 - 1999 micro ohms/ 19.99 milli ohms/ 199.9 milli ohms/ 1999 milli ohms/ 19.99 ohms/ 199.9 ohms/ 1999 ohms/ 19.99 k ohms. (ii) accuracy :plus or minus 0.2 percent . plus or minus 2 least counts in all ranges except plus or minus 0.5 percent plus or minus 3 least counts in 200 milli ohms, 20 milli ohms and 2000 micro ohms ranges. (iii) input : 230v single phase ac
Read moreFlame safety lamp gl-7 model volex, dgms approved lamp for gassy mines with a fixed filament unit fuel petrol or esso solvent 1425,flame safety lamp gl-50 model volex gl-50, dgms approved lamp for gassy mines spirit or petrol use as fuel for detecting methane,methanometer ch4 sensor range 0-100 percent,toximeter sensor range 0-1999 ppm,oximeter 02 sensor range 0-30 percent volume,multi gas detector with ch4 sensor ch4 0-100 percent lel, co 0-2000ppm, o2 0-25 percent volume, no2 0-50 ppm,multi gas detector with hydrocarbon, co, o2 and h2s sensors, hc 0-100 percent lel co 0-2000ppm o2 0-25 percent volume h2s 0-100ppm,explosimeter ch4 sensor 0-100 percent volume
Flame safety lamp gl-7 model volex, dgms approved lamp for gassy mines with a fixed filament unit fuel petrol or esso solvent 1425,flame safety lamp gl-50 model volex gl-50, dgms approved lamp for gassy mines spirit or petrol use as fuel for detecting methane,methanometer ch4 sensor range 0-100 percent,toximeter sensor range 0-1999 ppm,oximeter 02 sensor range 0-30 percent volume,multi gas detector with ch4 sensor ch4 0-100 percent lel, co 0-2000ppm, o2 0-25 percent volume, no2 0-50 ppm,multi gas detector with hydrocarbon, co, o2 and h2s sensors, hc 0-100 percent lel co 0-2000ppm o2 0-25 percent volume h2s 0-100ppm,explosimeter ch4 sensor 0-100 percent volume
Read moreSupply of type-sq-144 panel mounting taut band circular scale ( fd 240 deg ) moving coil dc ammeter analogue type, accuracy class 1.5 percent to is 1248 (part-1): 2003, 4th revision or latest, basic movement 75mv , scale range 0-1000 amps dc for detc icf 8-wheeler type tower wagon.
Supply of type-sq-144 panel mounting taut band circular scale ( fd 240 deg ) moving coil dc ammeter analogue type, accuracy class 1.5 percent to is 1248 (part-1): 2003, 4th revision or latest, basic movement 75mv , scale range 0-1000 amps dc for detc icf 8-wheeler type tower wagon.
Read moreT.m. ammeter moving coil type.- size 152x70x133mm scale 82 mm range 1.5-0-1.0 ka specification :- clw specn. no.clw/es/i-21 alt.-a
T.m. ammeter moving coil type.- size 152x70x133mm scale 82 mm range 1.5-0-1.0 ka specification :- clw specn. no.clw/es/i-21 alt.-a
Read moreProgrammable current transducer, input: 0-1aac, range: 0-1aac, output: 4-20 ma dc (dual output) , accu,multifunction meter for metering panels (with rs485modbus) , input: on site programmable-voltage - 10
Programmable current transducer, input: 0-1aac, range: 0-1aac, output: 4-20 ma dc (dual output) , accu,multifunction meter for metering panels (with rs485modbus) , input: on site programmable-voltage - 10
Read moreSet of digital voltmeter & ammeter with led display suitable for lhb power car & lslrd voltmeter range 0-1000 v ac, 4 digit, 3line, 7 segment, parameter displayed ac line-line voltage, ac line-neutral voltage. ammeter range 0-600 a ac,aux supply 12-48v dc, 50hz, ct 1a/5a programmable, 4 digit, 3line, 7 segment confirming to spec no. rdso/pe/sec/tl/0195-2019 (rev-0) or rcf spec no.- edts-103 rev-d, am-7 or latest . make : socomec/ rishabh/siemens/ l&t / schneider or equivalent.
Set of digital voltmeter & ammeter with led display suitable for lhb power car & lslrd voltmeter range 0-1000 v ac, 4 digit, 3line, 7 segment, parameter displayed ac line-line voltage, ac line-neutral voltage. ammeter range 0-600 a ac,aux supply 12-48v dc, 50hz, ct 1a/5a programmable, 4 digit, 3line, 7 segment confirming to spec no. rdso/pe/sec/tl/0195-2019 (rev-0) or rcf spec no.- edts-103 rev-d, am-7 or latest . make : socomec/ rishabh/siemens/ l&t / schneider or equivalent.
Read moreDigital lux meter with 3-1/2 digits lcd readings with maximum value 1999 digital lux meter with lux measuring range scale: 0.1-19990. make: kusam-meco/fluke/htc & metravi & meco or it s equivalent. note: the supplier should submit warranty and calibration certificates along with the material.
Digital lux meter with 3-1/2 digits lcd readings with maximum value 1999 digital lux meter with lux measuring range scale: 0.1-19990. make: kusam-meco/fluke/htc & metravi & meco or it s equivalent. note: the supplier should submit warranty and calibration certificates along with the material.
Read moreKnife double blade,file flat 200,contactor and auxiliary,limit switch,cut out relay,over current relay,undervoltage relay,portable electric drill,load bank,brake test arrangement,earth plate copper plate,earth plate gi plate,earth electrode,rheostat 25 ohm,rheostat 300ohm,rheostat 1 ohm 10 amp,rheostat 10 ohm 5 amp,ohm meter series type,ohm meter shunt type,digital multimeter 3 1by2 digit,ac voltmeter mi,milli voltmeter center zero,ammeter mc analog 0 to 500ma,ammeter mc analog 0 to 5a,ammeter mc analog 0 to 25a,ac ammeter mi 0 to 1 a,ac ammeter mi 0 to 5 a,ac ammeter mi 0 to 25 a,kilo wattmeter analog,digital wattmeter 230v 1kw 50hz,ac energy metersingle phase,power factor meter,frequency meter 45 to 55hz,lux meter lcd,tmeter digital photo,tong tester,megger analog 500,3point dc er,4 point dc er,wheat stone bridge,single phase variable auto transformer,phase sequence indicator,growler 230,ac er registence type er,ac er dol er,ac er star delta er manual,ac er s
Knife double blade,file flat 200,contactor and auxiliary,limit switch,cut out relay,over current relay,undervoltage relay,portable electric drill,load bank,brake test arrangement,earth plate copper plate,earth plate gi plate,earth electrode,rheostat 25 ohm,rheostat 300ohm,rheostat 1 ohm 10 amp,rheostat 10 ohm 5 amp,ohm meter series type,ohm meter shunt type,digital multimeter 3 1by2 digit,ac voltmeter mi,milli voltmeter center zero,ammeter mc analog 0 to 500ma,ammeter mc analog 0 to 5a,ammeter mc analog 0 to 25a,ac ammeter mi 0 to 1 a,ac ammeter mi 0 to 5 a,ac ammeter mi 0 to 25 a,kilo wattmeter analog,digital wattmeter 230v 1kw 50hz,ac energy metersingle phase,power factor meter,frequency meter 45 to 55hz,lux meter lcd,tmeter digital photo,tong tester,megger analog 500,3point dc er,4 point dc er,wheat stone bridge,single phase variable auto transformer,phase sequence indicator,growler 230,ac er registence type er,ac er dol er,ac er star delta er manual,ac er s
Read moreof your Industry type