Tender Details

Particulars Details
Title
Bus Coupler Control Of Hog A/ B Mode (S2 K8, S2 K9 Z) Auxiliary Contactor, Safety Lop Hog A & B Control Auxiliary Contactor, Hog A & B Over Load Auxiliary Contactor & Hog A & B Earth Leakage Auxiliary Contactor With 24 V Dc Coil, Aux. 3 No 1 Nc. Material Shall Conforming Rdso Specification No. Rdso/ Pe/ Spec/ Tl/0195 2019 (Rev 0). Material Is Schneider Part No. Ca3 Kn31 Bd Or Siemens Part No. 3 Rh21311 Bb40 Or Abb Part No. Tkc6 31 Z . Note: Material Shall Procure From Above Said Oem(abb/Siemens/Schne
Description
For Complete Deion And Other Details, Please Refer To Tender
Organisation Ministry of Railways | Central Govt. Ministry/Department
Tender Id 106542354
Reference
Number
NB245981
Tender Fee 0
EMD 0
Tender Value -
Place Guwahati
Link
View Original Tender Notice

https://www.ireps.gov.in/ireps/supply/pdfdocs/122024/106542354/viewNitPdf_4793851.pdf

Start Date December 03, 2024 21:28
End Date
Expired 16/12/2024

Expired 674 days ago

Search Similar tenders?

Bidding on tenders like this?

Partners, bid preparation, supplier quotes and GeM registration, from our team and partners.

Similar Tenders
Auxiliary contactor and contactor for lighting control

Auxiliary contactor and contactor for lighting control

Read more
Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21

Contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21

Read more
Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,

Contactor for net 1 & 2, rated voltage: 1000 v ac, rated kva 100 at rated voltage and 70 degrees c and utilization category 6 a, main pole 4, auxiliary contact: 2 no + 2 nc, control voltage: 415 v ac with surge suppressor with open type connections for l1, l2, l3, l4 terminals as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) or latest and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21 or latest to schneider cat. no. lc1d1150046n5 +la4da2n +ladn22,

Read more
Hog a & b main power contactors, 3 pole, 1000 v ac, 50 hz, suitable for 500 kva, 750 v ac onload switching under ac - 6a category at temperature of 70 degree celsius & coil voltage of 415v + 10 percent - 20 percent ac (250 - 500 v) with surge suppressor, 2no + 2nc, as per rdso spec no. rdso / pe / spec / d / tl / 0195-2019 (rev.-0) suitable for switch board cabinet for hog compliant lslrd coaches

Hog a & b main power contactors, 3 pole, 1000 v ac, 50 hz, suitable for 500 kva, 750 v ac onload switching under ac - 6a category at temperature of 70 degree celsius & coil voltage of 415v + 10 percent - 20 percent ac (250 - 500 v) with surge suppressor, 2no + 2nc, as per rdso spec no. rdso / pe / spec / d / tl / 0195-2019 (rev.-0) suitable for switch board cabinet for hog compliant lslrd coaches

Read more
Control transformer, 200va, 750/415v, type-ii, 50hz, single phase, h class insulation, dry type & air cooled, along with fuses complete, suitable for use in switch board cabinets of eog/hog lhb type ac coaches, powers cars, lhb garib rath ac coaches & smart lhb hog ac coaches, confirming to rdso specification no. rdso/pe/spec/ac/0203/-2020 (rev-0). make as per letter. no. el/7.1.108/sbc/main file dt: 16.04.2021 are bhasin packard, nacei, trolex, ramyaa, trinitron, kontact consortium, abrol o

Control transformer, 200va, 750/415v, type-ii, 50hz, single phase, h class insulation, dry type & air cooled, along with fuses complete, suitable for use in switch board cabinets of eog/hog lhb type ac coaches, powers cars, lhb garib rath ac coaches & smart lhb hog ac coaches, confirming to rdso specification no. rdso/pe/spec/ac/0203/-2020 (rev-0). make as per letter. no. el/7.1.108/sbc/main file dt: 16.04.2021 are bhasin packard, nacei, trolex, ramyaa, trinitron, kontact consortium, abrol o

Read more
Contactor k44 for 60 kva transformer, rated current: 95 amps, rated voltage: 690 v ac, main pole: 4, aux contact: 1no + 1nc control voltage: 230 v ac (168 v ac- 300 v ac means 230 v ac +/- 30 percent) with surge suppressor as per rdso spec no. rdso/pe/spec/ ac/0184-2015 (rev - 1) or latest and as per update of common bom items issued by rdso lr.no. el/7.1.108/mssbc, dt 17/09/21 or latest, to abb model no. af 116b-40, schneider model no. lc1d1150046m5 + la4da2u, c&s model no. lc1fdp1154u5+la9f9

Contactor k44 for 60 kva transformer, rated current: 95 amps, rated voltage: 690 v ac, main pole: 4, aux contact: 1no + 1nc control voltage: 230 v ac (168 v ac- 300 v ac means 230 v ac +/- 30 percent) with surge suppressor as per rdso spec no. rdso/pe/spec/ ac/0184-2015 (rev - 1) or latest and as per update of common bom items issued by rdso lr.no. el/7.1.108/mssbc, dt 17/09/21 or latest, to abb model no. af 116b-40, schneider model no. lc1d1150046m5 + la4da2u, c&s model no. lc1fdp1154u5+la9f9

Read more
Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)

Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)

Read more
Power contactor [with diode] for compressor unit of lhb type ac coaches, 3 pole, rated current- 32 a (at rated voltage & ac-3 utilization category), rated voltage- 690 v, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, conforming to rdso spec no. rdso / pe / spec / ac / 0184-2015 (rev1), suitable for lhb type ac coaches switch board cabinet [place of intallation- s1k33, s1k34, s1k38, s1k39]. accepted make & cat nos.: - as per sr. no. 60 of common bom of rdso letter no. e

Power contactor [with diode] for compressor unit of lhb type ac coaches, 3 pole, rated current- 32 a (at rated voltage & ac-3 utilization category), rated voltage- 690 v, coil voltage 77-143 vdc, with surge supressor, with 1 nc aux contact, conforming to rdso spec no. rdso / pe / spec / ac / 0184-2015 (rev1), suitable for lhb type ac coaches switch board cabinet [place of intallation- s1k33, s1k34, s1k38, s1k39]. accepted make & cat nos.: - as per sr. no. 60 of common bom of rdso letter no. e

Read more
Auxiliary contactor with diode for lhb power car. coil voltage-24v dc, 2no +2 nc, mounting: din rail, as per abb type- tkc6-22z-f, rc7/127 or gjh1213061 r5221, rc7/127, siemensof sl.no 66,67 as per bom attached note: 1) the firm should submit necessary test certificates along with materials for acceptance. 2) firm should mention make and model no. while participating in the tender.

Auxiliary contactor with diode for lhb power car. coil voltage-24v dc, 2no +2 nc, mounting: din rail, as per abb type- tkc6-22z-f, rc7/127 or gjh1213061 r5221, rc7/127, siemensof sl.no 66,67 as per bom attached note: 1) the firm should submit necessary test certificates along with materials for acceptance. 2) firm should mention make and model no. while participating in the tender.

Read more
Power contactor 750 amps, 1000v, 3 pole ac- 3 duty with coil voltage 250-500v, 50/60 hz/dc (code-71) and auxiliary contacts (4 no+ 4 nc) suitable for switch board cabinet of lhb ac power car, confirming to rcf spec. no. edts 103-rev-d, am-7. make: abb, part no. af750-30-11, order code: 1sfl637001r7111. spec: rcf spec no. edts 103-rev-d, am-7. make: abb. siemens & telemecanique france.

Power contactor 750 amps, 1000v, 3 pole ac- 3 duty with coil voltage 250-500v, 50/60 hz/dc (code-71) and auxiliary contacts (4 no+ 4 nc) suitable for switch board cabinet of lhb ac power car, confirming to rcf spec. no. edts 103-rev-d, am-7. make: abb, part no. af750-30-11, order code: 1sfl637001r7111. spec: rcf spec no. edts 103-rev-d, am-7. make: abb. siemens & telemecanique france.

Read more