Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Bus Coupler Control Of Hog A / B Mode Auxiliary Contactor (S2 K10 & S2 K11) With 24 V Dc Coil, Aux. 3 No 1 Nc
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106533632 |
|
Reference Number |
45245288 |
| Tender Fee | 0 |
| EMD | 420 |
| Tender Value | - |
| Place | New Delhi |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/122024/106533632/viewNitPdf_4783494.pdf |
| Start Date | November 23, 2024 18:39 |
| End Date |
Expired
11/12/2024
Expired 674 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Supply of auxiliary contactor with diode dc: 24v
Supply of auxiliary contactor with diode dc: 24v
Read moreStarter delta starter contactor 415 vac 32a, 50hz motor rating 15kw with auxiliary contacts 1 no+ 1nc of star delta starter for radiator fan motor of lhb power caras
Starter delta starter contactor 415 vac 32a, 50hz motor rating 15kw with auxiliary contacts 1 no+ 1nc of star delta starter for radiator fan motor of lhb power caras
Read moreAuxiliary switch and lever assembly for em contactor having two aux. contact switch [one switch having 2 nc, 01 no. and other switch having 1nc, 02 no. contacts] as per clw drawing no. 2twd.291.053 alt-3, 3twd.291.049 alt-1, 3twd.291.057 alt.1 and specn.no. 4tts.291.002 alt-2
Auxiliary switch and lever assembly for em contactor having two aux. contact switch [one switch having 2 nc, 01 no. and other switch having 1nc, 02 no. contacts] as per clw drawing no. 2twd.291.053 alt-3, 3twd.291.049 alt-1, 3twd.291.057 alt.1 and specn.no. 4tts.291.002 alt-2
Read moreJaystick controller xd2 al221,latch relay type ca2dk122f7,schneider pwr contactor 3p 40a lc1d40f7,3pole contactor lc1 d80p7 80a ic 1122518,aux contactor cad32b7 code 0122590 24v,selector switch assy xb 2bj21,jaystick controller xd2 lc21,time delay relayfor la2 d22 p 8350,telemech contactor type lc1 d2510 f7,3pole contactor d115fe7 115a ic 1122540,adder block telemecanique lai d11p 3790,t and c make aux contact block for la1 d20,t and c make aux.contact block for la1 do2,inst aux contact block ty lai dn 22,aux contact block for la1 do4 p 8350,t and c make aux contact block for la1 d40,t and c make aux contact block for la1 d13,telemecanique m k timers la3 d 22 p 3790
Jaystick controller xd2 al221,latch relay type ca2dk122f7,schneider pwr contactor 3p 40a lc1d40f7,3pole contactor lc1 d80p7 80a ic 1122518,aux contactor cad32b7 code 0122590 24v,selector switch assy xb 2bj21,jaystick controller xd2 lc21,time delay relayfor la2 d22 p 8350,telemech contactor type lc1 d2510 f7,3pole contactor d115fe7 115a ic 1122540,adder block telemecanique lai d11p 3790,t and c make aux contact block for la1 d20,t and c make aux.contact block for la1 do2,inst aux contact block ty lai dn 22,aux contact block for la1 do4 p 8350,t and c make aux contact block for la1 d40,t and c make aux contact block for la1 d13,telemecanique m k timers la3 d 22 p 3790
Read moreAuxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Auxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Read moreAuxiliary contactor with diode for lhb power car. coil voltage-24v dc, 2no +2 nc, mounting: din rail, as per abb type- tkc6-22z-f, rc7/127 or gjh1213061 r5221, rc7/127, siemensof sl.no 66,67 as per bom attached note: 1) the firm should submit necessary test certificates along with materials for acceptance. 2) firm should mention make and model no. while participating in the tender.
Auxiliary contactor with diode for lhb power car. coil voltage-24v dc, 2no +2 nc, mounting: din rail, as per abb type- tkc6-22z-f, rc7/127 or gjh1213061 r5221, rc7/127, siemensof sl.no 66,67 as per bom attached note: 1) the firm should submit necessary test certificates along with materials for acceptance. 2) firm should mention make and model no. while participating in the tender.
Read moreContactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest
Contactor (with diode) for ventilation fan unit 1 & 2 condenser cd1. 1, cd1.2, cd 2.1 cd 2.2 heater 1 & 2, rated current: 16 a (at rated voltage & ac-3 utilization category) rated voltage: 690 v ac main pole: 3 no aux contact: 1nc, control voltage: 77-143 v dc with surge suppressor make: siemens (3rt2018-1bf42 3rt2916-1jl00) and lk (l&t) (cs965671 ooo +cs96586 oooo) as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184 percent u20132015 (rev-2) or latest
Read moreBus coupler control of hog a / b mode auxiliary contactor.
For complete deion and other details, please refer to tender
Read moreHog a & b control auxiliary contactor (s2k8 & s2k9) with 24v dc coil, aux. 3no 4nc suitable for switch board cabinet for hog compliant lslrd coaches
For complete deion and other details, please refer to tender
Read moreof your Industry type