Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
About Tender
🚂 Procurement Opportunity: Titanium Interference Screw And Acl Set 🏫🔧 The Ministry Of Railways, Specifically The Central Government Ministry/Department, Is Seeking A Reliable Supplier For Titanium Interference Screws, 7 Mm X 25 Mm, Along With A Complete Anterior Cruciate Ligament (Acl) Set, Instrumentation, And The Full Range Of Implants Required For Surgery. 📅 Bid Submission Deadline: May 16, 2024, 11:00 Am Interested Suppliers Must Provide A Comprehensive Bid That Includes Detailed Specifications, Pricing, And Delivery Timelines. The Supplier Should Be Capable Of Supplying The Entire Set Of Products Necessary For The Surgery At The Time Of Need. For Complete Details And Tender Specifications, Please Refer To The Tender Document. Keywords: Titanium Interference Screw, Acl Set, Implant, Surgery, Ministry Of Railways, Central Government, Tender, Procurement| Particulars | Details |
|---|---|
| Title |
14477 Titanium Interference Screw 7 Mm X 25 Mm The Firm Should Supply Whole Acl Set And Instrumentation And All Range Of Implant At The Time Of Surgery.
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106337652 |
|
Reference Number |
H1241489 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Mumbai CST |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/052024/106337652/viewNitPdf_4564435.pdf |
| Start Date | May 08, 2024 22:41 |
| End Date |
Expired
16/05/2024
Expired 886 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Implant for acl reconstruction set consisting of acl tight rope rt -1 ,biocomposite interference screw 1, and fiber wire - 2 -
Implant for acl reconstruction set consisting of acl tight rope rt -1 ,biocomposite interference screw 1, and fiber wire - 2 -
Read moreInj. dexamethasone intravitreal implant 0.7 mg [product should be available inthe manufacturing firm s approved product list of railway board ai 2026-27
Inj. dexamethasone intravitreal implant 0.7 mg [product should be available inthe manufacturing firm s approved product list of railway board ai 2026-27
Read moreTrochanteric femur nail advanced system one set. spec: (1) 9 mm to 12 mm diameter with inbuilt set screw. (2) should be capable of allowing cannulated screw or blade (one) with same hole in proximal part. (3) end of blade and screw should be porous to allow augmentation with 5 mm distal locking option (two). (4) material should be titanium molybdenum. (complete range of size shape and side specific implant with instrumentation should be available at the time of surgery).[ item code no.:s6155
Trochanteric femur nail advanced system one set. spec: (1) 9 mm to 12 mm diameter with inbuilt set screw. (2) should be capable of allowing cannulated screw or blade (one) with same hole in proximal part. (3) end of blade and screw should be porous to allow augmentation with 5 mm distal locking option (two). (4) material should be titanium molybdenum. (complete range of size shape and side specific implant with instrumentation should be available at the time of surgery).[ item code no.:s6155
Read moreVa fibula plate (1 plate + 8 va locking screws + 6 cortical screws). spec: locking anatomical five hole variable angle distal fibula plate with 8(2.7 mm) va screw for head and shaft with two 3.5 cortical screw option in head for syndesmotic layer and 4(2.7mm) cortical screw, variable angle locking screw should have option to lock at + - 15 degree of axis in any direction complete range of size shape and side specific implant with instrumentation at the time of surgery. implant should be us fda
Va fibula plate (1 plate + 8 va locking screws + 6 cortical screws). spec: locking anatomical five hole variable angle distal fibula plate with 8(2.7 mm) va screw for head and shaft with two 3.5 cortical screw option in head for syndesmotic layer and 4(2.7mm) cortical screw, variable angle locking screw should have option to lock at + - 15 degree of axis in any direction complete range of size shape and side specific implant with instrumentation at the time of surgery. implant should be us fda
Read more1) acetabular roof reinforecement titanium ring,cage or triflange cup of sizes 50mm, 54mm, 58mm, 62mm, 66mm 2) cannulated spinal pedicle screws for spine surgery for minimally invasive surgeries system, 3) nterbody fusion cage: implant & 4) plif cage 11 x 11 x 11 mm
1) acetabular roof reinforecement titanium ring,cage or triflange cup of sizes 50mm, 54mm, 58mm, 62mm, 66mm 2) cannulated spinal pedicle screws for spine surgery for minimally invasive surgeries system, 3) nterbody fusion cage: implant & 4) plif cage 11 x 11 x 11 mm
Read moreDisposable presterilised meniscal repair suture passing system with polyethylene button or anchor and 1 to 0 multi strand,meniscal cinch for all inside meniscal repair,all inside meniscal repair implant system.,titanium anchor 2.8 2.4 3.5 5.0 mm components as under,bio anchor 2.8mm 2.4 3.5 5.0mm,suture disc for acl pcl reconstruction titanium all sizes pre sterilised.,titanium endobutton with adjustible length suspensory loop made of suture made of uhwpe core with braided fixation of tendon graft,end resector for arthroscopic shaver system disposable presterilised 3 to 5.5 cm diam,arthroscopic burr all types including acromioplasty burr and conical burrs size 3 to 5.5 mm disposable presterilised,sterile packed cork screw 4.5 mm anchorwith 2 x no. 2 preloaded suture made of uhwpe core cuff repair,sterile packed cork screw 6.5 mm anotator cuff repair,sterile packed bioabsorbable anchor with single loaded sliding suture made of uhwpe core with braided polyester jacket 2.4 2.8 3.5 mm,sterile packed titanium ancho
Disposable presterilised meniscal repair suture passing system with polyethylene button or anchor and 1 to 0 multi strand,meniscal cinch for all inside meniscal repair,all inside meniscal repair implant system.,titanium anchor 2.8 2.4 3.5 5.0 mm components as under,bio anchor 2.8mm 2.4 3.5 5.0mm,suture disc for acl pcl reconstruction titanium all sizes pre sterilised.,titanium endobutton with adjustible length suspensory loop made of suture made of uhwpe core with braided fixation of tendon graft,end resector for arthroscopic shaver system disposable presterilised 3 to 5.5 cm diam,arthroscopic burr all types including acromioplasty burr and conical burrs size 3 to 5.5 mm disposable presterilised,sterile packed cork screw 4.5 mm anchorwith 2 x no. 2 preloaded suture made of uhwpe core cuff repair,sterile packed cork screw 6.5 mm anotator cuff repair,sterile packed bioabsorbable anchor with single loaded sliding suture made of uhwpe core with braided polyester jacket 2.4 2.8 3.5 mm,sterile packed titanium ancho
Read more6amps,single pole, dc mcb,130v dc (rated6amps,single pole, dc mcb,130v dc (rated voltage) with extended terminals as per rdso drg. skel-3700, alt 1 and skel 4034, alt 1 and rdso specn.no. spec/e-12/1/04 of march 1992 with amendment 1 of june 1993 (with punching of indian railway emblem & rdso specification). makes/brands: indoasian/ c&s/ havells/ legrands/ abb/ bch/ l&t/ schneider/ siemens/ rbco only. the firm should submit routing test certificate at the time of supply of material.
6amps,single pole, dc mcb,130v dc (rated6amps,single pole, dc mcb,130v dc (rated voltage) with extended terminals as per rdso drg. skel-3700, alt 1 and skel 4034, alt 1 and rdso specn.no. spec/e-12/1/04 of march 1992 with amendment 1 of june 1993 (with punching of indian railway emblem & rdso specification). makes/brands: indoasian/ c&s/ havells/ legrands/ abb/ bch/ l&t/ schneider/ siemens/ rbco only. the firm should submit routing test certificate at the time of supply of material.
Read moreRoller bioabsorbable interference screw of any size as per requirement- the firm should supply whole acl set and instrumentation and all range of implant at the time of surgery.
For complete deion and other details, please refer to tender
Read moreRoller bioabsorbable interference screw of any size as per requirement- the firm should supply whole acl set and instrumentation and all range of implant at the time of surgery.
For complete deion and other details, please refer to tender
Read moreRoller bioabsorbable interference screw of any size as per requirement- 1.should be made of poly (l-lactic acid) 2.should be sterile double packed 3.the firm should supply whole acl set and instrumentation and all range of implant at the time of surgery.
For complete deion and other details, please refer to tender
Read moreof your Industry type