Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Making Of 02 No. Transformer Shed And 01 No. Foundation For Vcb With Earth Pit For Indoor Type Transformer At Regional Store And Parej Filter Plant Of Peocp Under Hazaribagh Area
|
| Description |
Making Of 02 No. Transformer Shed And 01 No. Foundation For Vcb With Earth Pit For Indoor Type Transformer At Regional Store And Parej Filter Plant Of Peocp Under Hazaribagh Area
|
| Organisation | Central Coalfields Limited | Public Sector Undertakings |
| Tender Id | 2025_CCL_335524_1 |
|
Reference Number |
GM(H)/EnM/Tender/25-26/06 |
| Tender Fee | 0 |
| EMD | 9000 |
| Tender Value | - |
| Place | PEOCP |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=347811 |
| Start Date | May 16, 2025 16:30 |
| End Date |
Expired
27/05/2025
Expired 506 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Preventive maintenance of 33kv indoor panel and outdoor breaker of 10 mva, 33kv/11kv andrewyule transformer -2 at southloyabad substation and 11kv vcb of basuria dhansar and gonudhia feeder at godhur switching substation under area
Preventive maintenance of 33kv indoor panel and outdoor breaker of 10 mva, 33kv/11kv andrewyule transformer -2 at southloyabad substation and 11kv vcb of basuria dhansar and gonudhia feeder at godhur switching substation under area
Read moreEl.d.c.nosmii/p1/3680/2026 overhauling 4nos 1000 kva oil type transformer including filtration top up of new tr oil 1 no of earth fault relay master relay available in 11kv vcb accessories transport charges available at amma kalaignar maaligai
Overhauling of 4 nos 1000 kva oil type transformer including filtration and top up of new tr oil 1 no of earth fault relay master relay available in the 11 kv vcb accessories transport charges available at amma maaligai muthamizh arignar kalaign
Read moreVcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Vcb aux rotary switch part no boarc,live line indication 3 point 3kv part no hl18,control relay part no boplaco2,earth leakage relay 50 750ma with time l part no elm7lats80m,ht bushing part no t33,indicating lamp part no lab9vcb33,actuator no plus nc part no boes1,vcb closing coil part no 650405,mcb part no botp6,current transformer for ammeter part no 12020055,vcb shunt trip coil part no 650605,vacuum interrupter part no 650400,vacuum circuit breaker 3 point 3 kv part no vulcan,no contact element type v2 part no bov2,capacitor trip device part no raptor,voltmeter part no vmso65,ammeter 200 by 5 for vcb part no 130a0200sov33,ammeter 300 by 5 for vcb part no 130a0300sov33,isolator 400a part no kie33,potential transformer 3 point 3 kv part no htptl1,hrc ht pt fuse part no boabwna,fuse terminal part no bokudf4,indicating lamp part no lab9tsuht,bullet pin up to 3 point 3 kv 300a part no bobp3,hv bushing part no httc,neutral moniotring relay with resistance part no nrmr,current transformer part no bo4005ctr,contro
Read moreProvision of transformer fencing with making of earth pit of different location of parej east oc project under hazaribagh area.
Provision of transformer fencing with making of earth pit of different location of parej east oc project under hazaribagh area.
Read moreRepair and maintenance of e and m building at parej under peocp of hazaribagh area
Repair and maintenance of e and m building at parej under peocp of hazaribagh area
Read moreRe-strengthening and re-jumpering of 440 o.h. line of parej colony of peocp under hazaribagh area.
Re-strengthening and re-jumpering of 440 o.h. line of parej colony of peocp under hazaribagh area.
Read moreRepairing/revival of cctv surveillance system installed at regional store parej under hazaribagh area.
Repairing/revival of cctv surveillance system installed at regional store parej under hazaribagh area.
Read moreComplete repairing and reconditioning 02 nos. electrotecknika make 3.3 kv 400 amp. vcb switch, s.l no.-et-4056 and et-4049 installed at parej filter plant of peocp under hazaribagh area.
Complete repairing and reconditioning 02 nos. electrotecknika make 3.3 kv 400 amp. vcb switch, s.l no.-et-4056 and et-4049 installed at parej filter plant of peocp under hazaribagh area.
Read moreRepair and maintenance of regional store office and day to day cleaning of store premises at regional store parej under gm unit, hazaribagh area
Repair and maintenance of regional store office and day to day cleaning of store premises at regional store parej under gm unit, hazaribagh area
Read moreProviding 315 kva, 11/0.433 kv indoor transformer and 11 kv indoor ht vcb panel with allied works at regional training center, bhubaneswar.
Providing 315 kva, 11/0.433 kv indoor transformer and 11 kv indoor ht vcb panel with allied works at regional training center, bhubaneswar.
Read moreof your Industry type