Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Sitc Of Additional Addressable Smoke Detector And Response Indicator Ri In The Existing Fire Alarm Panel 10 Loop With Complete Accessories Cables And Connection In The Various Locations At Institute Block ,Jipmer
|
| Description |
Sitc Of Additional Addressable Smoke Detector And Response Indicator Ri In The Existing Fire Alarm Panel 10 Loop With Complete Accessories Cables And Connection In The Various Locations At Institute Block ,Jipmer
|
| Organisation | Central Public Procurement Portal 2 |
| Tender Id | 2023_HITE_173086_1 |
|
Reference Number |
HITES/FM/JIPMER/NIQ/23-24/015 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Trivandrum |
| Link |
View Original Tender Notice
https://etenders.gov.in |
| Start Date | November 03, 2023 19:30 |
| End Date |
Expired
14/11/2023
Expired 1068 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Provn of fire alarm system including smoke detector in three locations of 3asc
As per tender document
Read moreItem 1 - two loop addressable fire alarm control panel,item 2 - addressable manual call point with built in isolator,item 3 - addressable loop powered sounder,item 4 - addressable loop powered flasher,item 5 - addressable multi-criteria detector with built in isolator and accessories,item 6 - detector back box,item 7 - supply and laying of twisted pair 3 core, 2.5 sq mm power cable,item 8 - supply and laying of 2c x 1.5sq.mm, twisted pair,item 9 - supply and laying of gi conduit 20 mm dia 1.6mm,item 10 - supply and laying of standard 20 mm lsi approved casing and capping,item 11 - 25 mm corrugated flexible conduit,item 12 - supply and fixing of miniature circuit breaker
Item 1 - two loop addressable fire alarm control panel,item 2 - addressable manual call point with built in isolator,item 3 - addressable loop powered sounder,item 4 - addressable loop powered flasher,item 5 - addressable multi-criteria detector with built in isolator and accessories,item 6 - detector back box,item 7 - supply and laying of twisted pair 3 core, 2.5 sq mm power cable,item 8 - supply and laying of 2c x 1.5sq.mm, twisted pair,item 9 - supply and laying of gi conduit 20 mm dia 1.6mm,item 10 - supply and laying of standard 20 mm lsi approved casing and capping,item 11 - 25 mm corrugated flexible conduit,item 12 - supply and fixing of miniature circuit breaker
Read moreSupply installation, testing and commissioning of microprocessor based standalone fire alarm control panel.,supply installation, testing and commissioning of addressable smoke detector with inbuilt optical smoke sensors as per nfpa style 7 wiring complete with base and termination as required,supply installation, testing and commissioning of addressable manual call point as per nfpa style 7 wiring complete as required with backbox,supply, installation, testing and commissioning of sounder strobe,supply, installation, testing and commissioning of addressable single output module, suitable to drive conventional notification devices or other power required equipment,supply, installation, testing and commissioning of loop isolator module, protection facility for addressable loop,supply, installation, testing and commissioning of 2c x 1.5 sq mm frls armored cable
Supply installation, testing and commissioning of microprocessor based standalone fire alarm control panel.,supply installation, testing and commissioning of addressable smoke detector with inbuilt optical smoke sensors as per nfpa style 7 wiring complete with base and termination as required,supply installation, testing and commissioning of addressable manual call point as per nfpa style 7 wiring complete as required with backbox,supply, installation, testing and commissioning of sounder strobe,supply, installation, testing and commissioning of addressable single output module, suitable to drive conventional notification devices or other power required equipment,supply, installation, testing and commissioning of loop isolator module, protection facility for addressable loop,supply, installation, testing and commissioning of 2c x 1.5 sq mm frls armored cable
Read moreSupply, installation, testing and commissioning of smoke detector and fire alarm system at 21 (twenty-one) nos. store centres under the jurisdiction of purvanchal vidyut vitran nigam limited (puvvnl), varanasi
Supply, installation, testing and commissioning of smoke detector and fire alarm system at 21 (twenty-one) nos. store centres under the jurisdiction of purvanchal vidyut vitran nigam limited (puvvnl), varanasi
Read moreSitc of 14 zone microprocessor based automatic fire detection main control panel,augmentation in the all existing afd system,sitc of photo electric smoke detector,sitc of ionization smoke detector,sitc of electropneumatic type dual action heat detector,sitc of electronic hooter or conventional hooter with lmt,sitc of response indicator for existing panel of visual indication,sitc of manual call point,supplying and fixing of 20mm size of steel conduit,supplying and fixing of 25mm size steel conduit size,supplying and drawing frls pvc insulated copper conductor, single core cable size 2x1.5sqmm,supplying and drawing frls pvc insulated copper conductor, single core cable size 3x1.5sqmm,supplying and drawing frls pvc insulated copper conductor, single core cable size 4x1.5sqmm,supplying and drawing frls pvc insulated copper conductor, single core cable size 5x1.5sqmm,supplying and drawing frls pvc insulated copper conductor, single core cable size 6x1.5sqmm,supplying and drawing frls pvc insulated copper conducto
Sitc of 14 zone microprocessor based automatic fire detection main control panel,augmentation in the all existing afd system,sitc of photo electric smoke detector,sitc of ionization smoke detector,sitc of electropneumatic type dual action heat detector,sitc of electronic hooter or conventional hooter with lmt,sitc of response indicator for existing panel of visual indication,sitc of manual call point,supplying and fixing of 20mm size of steel conduit,supplying and fixing of 25mm size steel conduit size,supplying and drawing frls pvc insulated copper conductor, single core cable size 2x1.5sqmm,supplying and drawing frls pvc insulated copper conductor, single core cable size 3x1.5sqmm,supplying and drawing frls pvc insulated copper conductor, single core cable size 4x1.5sqmm,supplying and drawing frls pvc insulated copper conductor, single core cable size 5x1.5sqmm,supplying and drawing frls pvc insulated copper conductor, single core cable size 6x1.5sqmm,supplying and drawing frls pvc insulated copper conducto
Read moreCpu,communication card,dual loop card,single loop card,addressable smoke detector,addressable manua
Read more
Wireless addressable smoke detector,wireless addressable heat detector,wireless fire alarm panel,mc