Water Purifiers & RO Plants
Learn when to choose RO, UV, UF or commercial RO plants, what capacity you need, and get quotes from water treatment suppliers.
Tell us what you need. Our team finds suppliers, checks availability and gets you quotes, usually within one working day.
Choose your requirement
Typical configurations. Pick one to start your request; the exact make and specifications are confirmed with suppliers.
-
Under-sink / wall-mounted RO
For small offices, clinics and pantries serving up to about 20–30 people.
- Capacity
- About 10–25 LPH
- Installation
- Wall or under-sink
- Purification
- RO with UV or UF options
- Storage tank
- Built in, about 7–12 L
- Suitable for
- Small offices, pantries
- Water source
- Municipal or borewell
-
Commercial RO, 25–50 LPH
For schools, shops and medium offices that need a steady supply of purified water for 50–150 people.
- Capacity
- 25–50 LPH
- Installation
- Floor-standing, plumbed
- Purification
- RO with UV or UF options
- Storage tank
- Separate tank, about 50–100 L
- Suitable for
- Schools, offices, shops
- Water source
- Municipal or borewell
-
Commercial RO, 100–500 LPH
For factories, hospitals, hostels and large campuses needing bulk purified water throughout the day.
- Capacity
- 100–500 LPH
- Installation
- Plant room, skid-mounted
- Purification
- RO with pre-treatment; UV optional
- Storage tank
- Large external tank
- Suitable for
- Factories, hospitals, hostels
- Water source
- Borewell, tanker or municipal
-
RO + water cooler combo
For corridors, canteens and schools wanting chilled and normal purified water from one unit.
- Capacity
- About 25–100 LPH RO
- Installation
- Floor-standing, plumbed
- Purification
- RO with UV or UF options
- Storage tank
- Built-in cooling tank, 20–80 L
- Suitable for
- Corridors, canteens, schools
- Water source
- Municipal or borewell
-
Not sure which one?
Tell us where and how it will be used, and we'll suggest the right option.
Compare options
| Under-sink / wall-mounted RO | Commercial RO, 25–50 LPH | Commercial RO, 100–500 LPH | RO + water cooler combo | |
|---|---|---|---|---|
| Capacity | About 10–25 LPH | 25–50 LPH | 100–500 LPH | About 25–100 LPH RO |
| Installation | Wall or under-sink | Floor-standing, plumbed | Plant room, skid-mounted | Floor-standing, plumbed |
| Purification | RO with UV or UF options | RO with UV or UF options | RO with pre-treatment; UV optional | RO with UV or UF options |
| Storage tank | Built in, about 7–12 L | Separate tank, about 50–100 L | Large external tank | Built-in cooling tank, 20–80 L |
| Suitable for | Small offices, pantries | Schools, offices, shops | Factories, hospitals, hostels | Corridors, canteens, schools |
| Water source | Municipal or borewell | Municipal or borewell | Borewell, tanker or municipal | Municipal or borewell |
Typical values; they vary by make and model.
What your quote should include
- Exact make, model and specifications offered
- Unit price and GST
- Delivery charges and time to your location
- Installation, if needed
- Warranty and after-sales service
How it works
- Share your requirement: quantity, specifications and delivery location.
- Our team finds suppliers and checks availability.
- You receive quotes and decide. There's no obligation to buy.
Buying guide
Types
- RO (reverse osmosis) purifier — removes dissolved salts and is the usual choice where borewell or tap water has high TDS.
- UV purifier — treats microbes in low-TDS water and does not reduce dissolved salts.
- UF purifier — gravity or low-pressure membrane filter that removes particles and some microbes, needing no electricity in many models.
- Under-counter or wall-mounted office purifier — typically 10 to 25 litres per hour for a pantry or reception.
- Commercial RO plant — capacities from 50 to several thousand litres per hour for schools, hospitals, factories and housing societies, with pre-treatment and storage.
What to check before buying
- Get your water tested first: TDS, hardness, iron and turbidity decide whether RO, softener or pre-filter is needed.
- Output in litres per hour and the recovery rate, because RO rejects a share of input water.
- Membrane make and expected life, filter and cartridge replacement schedule.
- Material of tank and contact parts, which should be food grade.
- Electrical load, inlet pressure needs and space for a reject-water drain or reuse line.
- Installation, free service visits, AMC terms and a GST invoice.
Who buys them
Offices, schools, hospitals, shops, factories, housing societies, contractors, NGOs and government offices.
Frequently asked questions
What size RO plant do I need for a school?
Plan for roughly 3 to 5 litres of drinking water per person per day, then add margin for peak use. For 500 students this suggests a plant of about 250 to 500 litres per hour with a storage tank.
Is RO always necessary?
No. If a lab test shows low TDS, UV or UF may be sufficient, and removing too many salts is not always desirable.
How often should filters be changed?
Sediment and carbon cartridges are usually changed every few months and membranes after one to three years, depending on water quality. Common brands include Kent, Aquaguard, Pureit and Livpure.