Results for: Air Sampling Smoke Detection System
Find the latest Air Sampling Smoke Detection System tenders from different organizations. SigmaTenders helps you participate in these online e-Procurement tenders. We provide access to tender details, BOQs, and technical bids, along with bidding support for Air Sampling Smoke Detection System e-tenders. Stay informed with daily email alerts and comprehensive coverage across government websites, GeM, and e-Procurement portals.
Transformer for hot wire test of fire and smoke detection system, transformer ratio 240 volts to 06 volts, capable of supplying at least 30 ampere, voltmeter for input and output voltage and switch and power on led should be provided on panel of transformer ,air cooled type , copper wire windings as per spec no rdso/2008/cg-4 rev 6
For complete deion and other details, please refer to tender
Repair/maint of certain misc e/m equipment such as smoke detector/fire alarm system/ window/ spilit air conditioning/ aviation light along with connected e/m work at af stn nathatop under ge (af) udhampur
Repair/maint of certain misc e/m equipment such as smoke detector/fire alarm system/ window/ spilit air conditioning/ aviation light along with connected e/m work at af stn nathatop under ge (af) udhampur
Charging unit to jk exim (p) ltd part no [charging unit to jk exim (p) ltd part no. jk-fsd-1121 for automatic smoke/fire detection with alarm system (fds) in railway coaches as per rdso specification no. rdso/2008/cg- 04. (rev-5) or latest]
For complete deion and other details, please refer to tender
Services pertaining for oandm of electrical installations, window-split air conditioners and fire detection-fighting system of concors corporate office c-3 mathura road, us complex, additional office space at nsic mdbp building 2nd and 3rd floor, tra
Services pertaining for oandm of electrical installations, window-split air conditioners and fire detection-fighting system of concors corporate office c-3 mathura road, us complex, additional office space at nsic mdbp building 2nd and 3rd floor
Aden(hq-iii)jp sub division:-strengthening , rehabilitation and provision of air conditioning on non conditioning area at 2 nd floor of drm office and including provision of fire detection & supperssion system in hospital and drm office.
For complete deion and other details, please refer to tender
Portable hli and connecting cable (part no.: 2ed-2544774) for checking air flow reading of aspiration type automatic smoke and fire detection with alarm system installed in ac coaches as per rdso spec. no. rdso/2008/cg-04 (rev.5) dated aug-2019. details are attached as annexure - a. [qty 1 set consists of portable hli- 1 no. and connecting cable (2ed-2544774)- 1 no.] make- xtralis,sanrok or similar
For complete deion and other details, please refer to tender
๐ Procurement Bid for Portable HLI and Connecting Cable for Smoke and Fire Detection Systems ๐ The Ministry of Railways, specifically the Central Govt. Ministry/Department, is seeking bids for the supply of a Portable Heat Line Indicator (HLI) and Connecting Cable (Part No.: 2ED-2544774) as per RDSO Specification No. RDSO/2008/CG-04 (Rev. 5) dated Aug-2019. ๐ ๐ Detailed specifications and requirements are provided in the attached annexure (Annexure-A). The make acceptable for this tender is XTRALIS, SANROK, or similar. Bid Submission Deadline: May 02, 2024, 11:30 AM There is no tender fee or earnest money deposit (EMD) required for this bid. Interested suppliers should submit detailed bids, including technical and financial proposals, to meet the stringent specifications and quality standards as outlined in the tender documents. Keywords: Portable HLI, Connecting Cable, Smoke and Fire Detection, Ministry of Railways, RDSO Specification, Tender, Bid Submission, Gorakhpur
Supply, installation & commissioning of [supply, installation & commissioning of various sub-assemblies to convert rake formation type of fsds of make m/s sanrok to stand alone type automatic smoke/ fire detection system as per rdso specification no. rdso/2008/cg-04. rev.6. scope of supply and commissioning is enclosed at annexure-1.]
For complete deion and other details, please refer to tender
Nitrogen cylinder capacity 50l, 200 bar with pressure gauge fitted with fire rated automatic fire suppression activation solenoid valve with manual override lever duly filled with nitrogen at 200 bar (/-)10 percent for automatic smoke/fire detection with alarm system as per rdso specification no. rdso/2013/cg-06 (rev-2) amdt-1.
For complete deion and other details, please refer to tender
Supply of linear heat detector (lhd) cable (ul or en approved, 105-110 deg c, approx. 30 meters) compatible for automatic fire smoke detection and suppression system fitted in lhb pantry, as per rdso specification no. rdso/2013/cg-06. (rev.2) or latest. as per sanrok part no. 2ed-245-3545 or similar
For complete deion and other details, please refer to tender
Relay and communication card of vesda compact laser detector (part no. 2ed-255-4974) spare parts of automatic smoke/fire detection with alarm system for ac coaches as per rdso specification no. rdso/2008/cg-04. (rev-5). note: warranty should be 30 months from date of commissioning/ 36 month from the date of supply whichever is earlier.
For complete deion and other details, please refer to tender
Need support responding to this opportunity?
Get matched through GetSaarthi for documentation, proposal preparation, compliance readiness, and execution support.
Get Opportunity Matching Supportof your Industry type