Results for: AC Condenser
Find the latest AC Condenser tenders from different organizations. SigmaTenders helps you participate in these online e-Procurement tenders. We provide access to tender details, BOQs, and technical bids, along with bidding support for AC Condenser e-tenders. Stay informed with daily email alerts and comprehensive coverage across government websites, GeM, and e-Procurement portals.
Repairing of ac compressor, condensor and cooling coil and cleaning of ac connection line and refrigerant for zx-650h tata hitachi sl. no. -191/exc-2955 and ck300 back hoe sl. no. b-772 of bokaro ocp
Repairing of ac compressor, condenser and cooling coil and cleaning of ac connection line and refrigerant for zx-650h tata hitachi sl. no. -191/exc-2955 and ck300 back hoe sl. no. b-772 of bokaro ocp
๐ง Procurement Bid Invitation: AC Repair Services for Central Coalfields Limited ๐๏ธ Central Coalfields Limited (CCCL), a Public Sector Undertaking, is seeking bids from experienced service providers for the repair and maintenance of air conditioning systems. The specific equipment requiring service includes the AC compressor, condenser, cooling coil, and associated connection lines and refrigerant for the following machinery: ๐ ZX-650H Tata Hitachi Sl. No. -191/EXC-2955 ๐ CK300 back hoe Sl. No. B-772 The work scope encompasses the repair and maintenance of the AC systems at Bokaro OCP. ๐ Bid Submission Deadline: April 25, 2024, 6:00 PM A tender fee of INR 2700 is applicable, with no EMD required. Interested bidders should submit detailed proposals, including technical capabilities, experience, pricing, and timelines for service delivery. Keywords: AC Repair, Central Coalfields Limited, Public Sector Undertaking, Air Conditioning Maintenance, Bokaro OCP, Tender, Bid Invitation
Set of 02 cab ac items components consisting of (1) blower motor with double extended shaft with fan impeller for air conditioning unit, frame 63, frequency-50hz /- 5 percent , volts 415 /- 10 percent , rpm: 1360 with test certificate, as per rdso specification no. rdso/pe/spec/ac/0089, rev-0/ amendment no.1 or its latest- 05 nos. (2) condenser motor 0.15kw, frequency-50hz, frame 63, supply 415v ac /- 10 percent , 0.7 amps rpm: 1350, star connection, reference is: 325- 05 nos. for roof moun
For complete deion and other details, please refer to tender
Condenser fan motor 0.75kw/1 hp, 3 ph , 415 volts, 50 hz. class-h insulation, 1000 rpm (synchronous speed.), ip-56 as per iec 60529, continuous duty, frame size 90l suitable for face mounted (type c flange) as per rdso s specification no. rdso/pe/spec/ac/0089-2008(rev. -0), amendment no. 1 & 2 specn: rdso s specification no. rdso/pe/spec/ac/0089-2008(rev. -0), amendment no. 1 & 2
For complete deion and other details, please refer to tender
Condenser fan motor 0.75kw/1 hp, 3 ph , 415 volts, 50 hz. class-h insulation, 1000 rpm (synchronous speed.), ip-56 as per iec 60529, continuous duty, frame size 90l suitable for face mounted (type c flange) as per rdso s specification no. rdso/pe/spec/ac/0089-2008(rev. -0), amendment no. 1 & 2 specn: rdso s specification no. rdso/pe/spec/ac/0089-2008(rev. -0), amendment no. 1 & 2
For complete deion and other details, please refer to tender
Armo ei compound lights lifts water supply pumps fire fighting system fire alarm system pa system sub station and dg sets ac plant epabx telephone water softening plant 3 x 100 kva ups at ddu college dwarka new delhi
Treatment of water in condenser line of ac plant by electrostatic scale preventer methord
Aemo ei compound lights lifts water supply pumps fire fighting system fire alarm system pa system sub station and dg sets ac plant cctv epabx telephone water softening plant 3 x 100 kva ups at ddu college dwarka new delhi
Treatment of water in condenser line of ac plant by electrostatic scale preventer method
Condenser fan frp, suitable for use in sidwal make rmpu, axial flow number of blade 08/10, blade series material h nylon 66 rgf25 fr, hub dia 150 mm, hm material lm-6 motor mounting adaptor type, frp fan dia 21 inch, confirming to rdso specification no. elps/spec/ac/03(rev-2) may- 2009 with amendment no.1 & 2
For complete deion and other details, please refer to tender
Condenser fan blade suitable for 1400rpm motor made from frp material with aluminum hub overall unit dia. 540 mm. hub dia. 140 mm. bore dia. on hub for motor shaft of 19 mm. with 6 mm. keyway, dynamically balanced and confirming to part no. 4.40.2 of rdso spec. no. lps/spec/ac/03(rev-2) may 2009 or latest. as per drg.no. nil specn: nil
For complete deion and other details, please refer to tender
Contactor(with diode) for ventilation fa [contactor(with diode) for ventilation fan unit 1&2 condenser cd1.1, cd1.2, cd 2.1, cd 2.2, heater 1&2 :rated current : 16 a (at rated voltage & ac-3 utilization category) rated voltage : 690 v ac, main pole : 3 no, aux contact : 1 nc, control voltage : 77-143v dc with surge suppressor. suitable for k26,k28,k31,k32,k36,k37,k35,k40 as per bom of rdso spec rdso/pe/spec/0184-2015(rev-01) or latest. brands: l&t/siemens/schneider/abb only. 1) the firm should
For complete deion and other details, please refer to tender
Contactor(with diode) for ventilation fa [contactor(with diode) for ventilation fan unit 1&2 condenser cd1.1, cd1.2, cd 2.1, cd 2.2, heater 1&2 :rated current : 16 a (at rated voltage & ac-3 utilization category) rated voltage : 690 v ac, main pole : 3 no, aux contact : 1 nc, control voltage : 77-143v dc with surge suppressor. suitable for k26,k28,k31,k32,k36,k37,k35,k40 as per bom of rdso spec rdso/pe/spec/0184-2015(rev-01) or latest. brands: l&t/siemens/schneider/abb only. 1) the firm should
For complete deion and other details, please refer to tender
Need support responding to this opportunity?
Get matched through GetSaarthi for documentation, proposal preparation, compliance readiness, and execution support.
Get Opportunity Matching Supportof your Industry type