Supply, Installation And Commissioning Of Two Nos Of Ngr Monitoring System Along With Fail Safe Arrangement For Two Nos. Of 3.3 Kv/550 315 Kva Tsu In Quarry Sub Station Of Dalurband Ocp.
|
| Description |
Supply, Installation And Commissioning Of Two Nos Of Ngr Monitoring System Along With Fail Safe Arrangement For Two Nos. Of 3.3 Kv/550 315 Kva Tsu In Quarry Sub Station Of Dalurband Ocp.
|
| Organisation | Eastern Coalfields Limited | Public Sector Undertakings |
| Tender Id | 2024_ECL_302926_1 |
|
Reference Number |
GM-PND/EandM/23-24/175/3802 dated 27/02/2024 |
| Tender Fee | 0 |
| EMD | 3400 |
| Tender Value | - |
| Place | Dalurbandh OCP |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=313802 |
| Start Date | February 28, 2024 22:30 |
| End Date |
Expired
09/03/2024
Expired 950 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Auxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Auxiliary transformer 80va pri 500 525 550, part no. fs2004c,air breaker contactor 16amps, part no fs2003a,air break contactor 63 amps, part no fs2003e,direct acting thermal overload relay, part no fs2010a,earth leakage relay complete w.o. transf, part no fs2018,pilot relay 12v dc, part no fs2026,auxiliary contactor 2no 2nc 110v 415v 550v, part no fs2020,auxillary cantactor 3 no 1nc 110v 415v , part no fs2020a,i.s. pilot oanel instrinsically safe, part no fs2035,air break contactor 40amps upto 20hp 550v, part no fs2003c,isolator 200 amp,3.3 kv on off, part no ht100,vacuum contactor 400 amps, 3.3kv, part no ht200,bottle vaccum interrupture 400a for cont, part no ht202,auxiliary contactor 3no 1nc, 110v, part no ht208,resin cast p.t. 750va, 3.3kv 110 volt, part no ht300,resin cast p.t 300va 3.3kv 110v, 3 phase, part no ht350,resin cast moulded ct for o l relay 75 , part no ht600,resin cast moulded ct for ammeter 150 5, part no ht650,earth leakage relay unit complete witho, part no ht800,3 pole magnetic o l relay
Read moreInstallation and commissioning of two nos. of ngr monitoring system along with fail safe arrangement for two nos. 11kv/3.3kv, 1mva transformer at 6 no and 9 no sub-station at dalurband colliery.
Installation and commissioning of two nos. of ngr monitoring system along with fail safe arrangement for two nos. 11kv/3.3kv, 1mva transformer at 6 no and 9 no sub-station at dalurband colliery.
Read moreFor repairing of ht/lt controlling of tsu 3.3kv/550v,315kva
For repairing of ht/lt controlling of tsu 3.3kv/550v,315kva,sl.no.021 mine line for tetulmari colliery under sijua area
Read moreRepairing n rewinding of 315kva, 3.3kv/550v tsu of amritnagar colliery.
Repairing n rewinding of 315kva, 3.3kv/550v tsu of amritnagar colliery.
Read moreProviding and fixing of ngr at lt side of 1 m andb make 3.3kv550v 800kva power transformer installed at surface substation 2 gec make 315kva 3.3kv 550v flp tsu 3 mineline make 315kva 3.3kv 550v flp tsu installed at ug substation of khairaha ug mine
Providing and fixing of ngr at lt side of 1 m and b make 3.3kv550v 800kva power transformer installed at surface substation 2 gec make 315kva 3.3kv 550v flp tsu 3 mineline make 315kva 3.3kv 550v flp tsu installed at ug substation of khairaha ug min
Read moreRepairing of 05 nos. 315kva, 3.3kv/565v transwitch units (tsu) at rws chandametta
Repairing of 05 nos. 315kva, 3.3kv/565v transwitch units (tsu) at rws chandametta
Read moreSupply, installation and commissioning of 4 nos. neutral grounding resistance in 315kva, gec make 3.3kv/550v tsu installed at main dip/29l, 315kva, a/y make 3.3kv/550v tsu installed at 1l/14r and a/y make 3.3kv/550v tsu at 15l/17d and 150kva, 3.3kv/5
Supply, installation and commissioning of 4 nos. neutral grounding resistance in 315kva, gec make 3.3kv/550v tsu installed at main dip/29l, 315kva, a/y make 3.3kv/550v tsu installed at 1l/14r and a/y make 3.3kv/550v tsu at 15l/17d and 150kva, 3.3kv/5
Read moreof your Industry type