Mtps I Bm Unit Iv Aoh 2025 2026 Cutting Patch Welding On The Eroded Portion Of The Fg Duct From Eco Outlet To Aph Inlet Renewal Of Support Beam Both Inlet And Outlet Of Aph Hoppers And Renewal Of Eroded Duct Support Pipes Both A And B Sides
|
| Description |
Mtps I Bm Unit Iv Aoh 2025 2026 Cutting Patch Welding On The Eroded Portion Of The Fg Duct From Eco Outlet To Aph Inlet Renewal Of Support Beam Both Inlet And Outlet Of Aph Hoppers And Renewal Of Eroded Duct Support Pipes Both A And B Sides
|
| Organisation | TNEB Limited | State Govt. and UT |
| Tender Id | 2025_EB_589177_1 |
|
Reference Number |
CE / MTPS-I / SE / M-I / BM /OT. 216 / 2025-26 |
| Tender Fee | 0 |
| EMD | 5100 |
| Tender Value | - |
| Place | Mettur Thermal Power Station-I / Mettur Dam |
| Link |
View Original Tender Notice
https://tntenders.gov.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=703846 |
| Start Date | August 05, 2025 18:30 |
| End Date |
Expired
11/08/2025
Expired 429 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Ttps mech ii bm unit i rectification of supporting structure of aph duct hopper area reconditioning of eroded portion of primary secondary air damper duct and manhole doors
Ttps mech ii bm unit i rectification of supporting structure of aph duct hopper area reconditioning of eroded portion of primary secondary air damper duct and manhole doors
Read moreProcurement of biplane blade (middle) of aph fg inlet damper installed in unit-1 and 2 at 2x600mw, sstpp, mppgcl, dongalia, distt. khandwa, (m.p.).
Procurement of biplane blade (middle) of aph fg inlet damper installed in unit-1 and 2 at 2x600mw, sstpp, mppgcl, dongalia, distt. khandwa, (m.p.).
Read moreProcurement of 100 nb ms pipes to replace damaged bracing pipes in both unit boiler ducts (aph, esp and id fan inlet/outlet ducts) in aoh at stpp, jaipur, mancherial, telangana
Procurement of 100 nb ms pipes to replace damaged bracing pipes in both unit boiler ducts (aph, esp and id fan inlet/outlet ducts) in aoh at stpp, jaipur, mancherial, telangana
Read moreTtps mechiibm unit iiirenewal of severely eroded parent duct plate in top side walls of aphab flue gas outlet duct and replacement of wornout esp hopper lower part with hopper door renewal of wornout esp hopper upper part and providing insulation
Ttps mechiibm unit iiirenewal of severely eroded parent duct plate in top side walls of aphab flue gas outlet duct and replacement of wornout esp hopper lower part with hopper door renewal of wornout esp hopper upper part and providing insulation
Read moreMtps i mill plant unit ii dismantling and assembling of coal pipes with bends and renewal of eroded pipes of length at about 15 mtr length along with bends between mill outlet elbow and fuel inlet elbow during aoh 2026 27
Mtps i mill plant unit ii dismantling and assembling of coal pipes with bends and renewal of eroded pipes of length at about 15 mtr length along with bends between mill outlet elbow and fuel inlet elbow during aoh 2026 27
Read moreMtps i mill plant unit ii patch welding of eroded portion of hot air ducts joints and coal mill 2a to 2f vertical inlet area above the horizontal area and below the expansion joint providing insulation for pa inlet duct in coal mills 2a to 2f during
Mtps i mill plant unit ii patch welding of eroded portion of hot air ducts joints and coal mill 2a to 2f vertical inlet area above the horizontal area and below the expansion joint providing insulation for pa inlet duct in coal mills 2a to 2f during
Read moreMtps i mill plant unit ii dismantling and assembling of coal pipe bends and patch welding the eroded portions of coal bends pipelines between mill outlet elbow and fuel inlet elbow during annual overhaul 2026 27
Mtps i mill plant unit ii dismantling and assembling of coal pipe bends and patch welding the eroded portions of coal bends pipelines between mill outlet elbow and fuel inlet elbow during annual overhaul 2026 27
Read moreMtps i tm unit ii renewal of gasket at water box side tube nest side condensate inlet and outlet flange inspection and cleaning of tube nest and hydraulic testing of lph 2 3 4 gc 1 ejector 2a vent condenser and renewal of gasket at deaerator main
Mtps i tm unit ii renewal of gasket at water box side tube nest side condensate inlet and outlet flange inspection and cleaning of tube nest and hydraulic testing of lph 2 3 4 gc 1 ejector 2a vent condenser and renewal of gasket at deaerator main
Read moreMtps i bm unit i aoh 2024 25 cutting and patch welding on the eroded portion of the fg duct from eco outlet to aph inlet renewal of support beam both inlet and outlet of aph hoppers and renewal of eroded duct support pipes both a and b sides
Mtps i bm unit i aoh 2024 25 cutting and patch welding on the eroded portion of the fg duct from eco outlet to aph inlet renewal of support beam both inlet and outlet of aph hoppers and renewal of eroded duct support pipes both a and b sides
Read moreMtps i bm unit ii aoh 2025 26 cutting and patch welding on the eroded portion of the fg duct from eco outlet to aph inlet renewal of support beam both inlet and outlet of aph hoppers and renewal of eroded duct support pipes both a and b sides
Mtps i bm unit ii aoh 2025 26 cutting and patch welding on the eroded portion of the fg duct from eco outlet to aph inlet renewal of support beam both inlet and outlet of aph hoppers and renewal of eroded duct support pipes both a and b sides