Tender Details

About Tender

🚂 Procurement Notice: 3 Phase Auto Change Over Switch 🔧 The Ministry Of Railways, Specifically The Central Government Ministry/Department, Is Seeking Bids For The Supply Of 3 Phase Auto Change Over Switches, Type Fgc 160, With A Rating Of 415 V, 160 A, 50 Hz, With A Maximum Residual Voltage (Ui) Of 800 V Ac, Complying With Iec 60947 3 And Is 13947 3 Standards. The Preferred Make Is L&T Or Similar. 📅 Bid Submission Deadline: May 20, 2024, 2:00 Pm Interested Bidders Are Advised To Review The Complete Tender Document For Detailed Specifications And Submission Guidelines. Keywords: 3 Phase Auto Change Over Switch, Type Fgc 160, 415 V 160 A 50 Hz, Iec 60947 3, Is 13947 3, L&T, Ministry Of Railways, Central Govt. Ministry/Department, Tender, Procurement
Particulars Details
Title
3 Phase Auto Change Over Switch. Type Fgc 160, Rating 415 V, 160 A, 50 Hz, Ui 800 V Ac, Iec 60947 3, Is 13947 3, Make L&T Or Similar
Description
For Complete Deion And Other Details, Please Refer To Tender
Organisation Ministry of Railways | Central Govt. Ministry/Department
Tender Id 106337488
Reference
Number
39245217A
Tender Fee 0
EMD 0
Tender Value -
Place Hazipur
Link
View Original Tender Notice

https://www.ireps.gov.in/ireps/supply/pdfdocs/052024/106337488/viewNitPdf_4561135.pdf

Start Date May 06, 2024 18:27
End Date
Expired 20/05/2024

Expired 880 days ago

Search Similar tenders?

Tender Support

Get help with filing, GeM registration, documents, or relevant tender alerts.

Similar Tenders
Heavy duty switch disconnection/load change over switch 250a, 415v, 50hz, ac 22a (is: 13947-3, ies 947-3) with 63 amp fuse suitable for fitment in 1400hp dpc.

Heavy duty switch disconnection/load change over switch 250a, 415v, 50hz, ac 22a (is: 13947-3, ies 947-3) with 63 amp fuse suitable for fitment in 1400hp dpc.

Read more
Disconnecting and earthing device, 8 pole, 2 way, no-off on load, 63a 750v ac (1000v insulation), 2no + 2nc with heavy handle and pad locking arrangement. in earth position, mounted in a stainless steel enclosure suitable for ac 23 duty conforming to is 13947/iec 947, to drawing no. m137, 0827407 of m/s schaltbau or catalogue no. 73342slb321 ogb of m/s l&t as per spec.no. edts 355 rev.1 amdt as per drg.no. n/a specn: is/iec 60947-3 (1999)

Disconnecting and earthing device, 8 pole, 2 way, no-off on load, 63a 750v ac (1000v insulation), 2no + 2nc with heavy handle and pad locking arrangement. in earth position, mounted in a stainless steel enclosure suitable for ac 23 duty conforming to is 13947/iec 947, to drawing no. m137, 0827407 of m/s schaltbau or catalogue no. 73342slb321 ogb of m/s l&t as per spec.no. edts 355 rev.1 amdt as per drg.no. n/a specn: is/iec 60947-3 (1999)

Read more
Motor protection circuit breaker (mpcb) for compressor unit and heater unit, current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3-pole, voltage rating 415 v ac, conforming to is/iec 60947-2; conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1); suitable for use in switch board cabinet of lhb type ac coaches. accepted make & cat. /model no.: rdso-approved make and model as per serial no. 39 of rdso letter no. el/7.1.108/mssbc dated 17.09.2

Motor protection circuit breaker (mpcb) for compressor unit and heater unit, current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3-pole, voltage rating 415 v ac, conforming to is/iec 60947-2; conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1); suitable for use in switch board cabinet of lhb type ac coaches. accepted make & cat. /model no.: rdso-approved make and model as per serial no. 39 of rdso letter no. el/7.1.108/mssbc dated 17.09.2

Read more
Ventilation fan motor of 5.0-5.5 kw/6.7-7.5 hp rating, 415v ac, 3-phase, 50hz, ip-65, insulation class-h, min 1440 rpm, roof mounted, as per rdso specification no. rdso/pe/spec/ac/0084-2008 (rev.1). suitable for use in lhb-type power cars. accepted make: m/s abb, m/s laxmi hydraulic, m/s crompton, m/s siemens, m/s kirloskar electric, or any other rdso-approved make.

Ventilation fan motor of 5.0-5.5 kw/6.7-7.5 hp rating, 415v ac, 3-phase, 50hz, ip-65, insulation class-h, min 1440 rpm, roof mounted, as per rdso specification no. rdso/pe/spec/ac/0084-2008 (rev.1). suitable for use in lhb-type power cars. accepted make: m/s abb, m/s laxmi hydraulic, m/s crompton, m/s siemens, m/s kirloskar electric, or any other rdso-approved make.

Read more
L and t hrc fuse 160a hn160 cat no sf 94131,fuse switch type fb 250 l and t,switches of 125a cat 415v sk95001,sdf type fn 630 tpn sk95521 l and t,switch disconnector fuse unit fn32,switch fuse unit 400a 415v tpn sh steel,mccb rating 400a 3pole 50ka,mccb dn0 100m 100a tm release l and t make,mccb mtx 2 0 dn2 250n 250a l and t make,add on block for ml10 12 contactor l and t,l and t make 110a ac3 ml6 contactor,power contactor 240v ac ty mnx400,power contactor 4 p 325a ty mcx 41,32 50 a bimetallic over load relay,mccb 125a,3 2 5 a over load relay,overload relay bimetalic

L and t hrc fuse 160a hn160 cat no sf 94131,fuse switch type fb 250 l and t,switches of 125a cat 415v sk95001,sdf type fn 630 tpn sk95521 l and t,switch disconnector fuse unit fn32,switch fuse unit 400a 415v tpn sh steel,mccb rating 400a 3pole 50ka,mccb dn0 100m 100a tm release l and t make,mccb mtx 2 0 dn2 250n 250a l and t make,add on block for ml10 12 contactor l and t,l and t make 110a ac3 ml6 contactor,power contactor 240v ac ty mnx400,power contactor 4 p 325a ty mcx 41,32 50 a bimetallic over load relay,mccb 125a,3 2 5 a over load relay,overload relay bimetalic

Read more
Click Here to Download Dockets
of your Industry type
Get customized tender Recommendations for your Enterprise