Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Control Panel,Smoke Detector,Beam Smoke Detector,Manual Call Point,Hooter Cum Strobe,24 V 10 Amp Pow
|
| Description |
|
| Organisation | Department of Defence | Ministry of Defence |
| Tender Id | GEM/2023/B/3954990 |
|
Reference Number |
- |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link |
View Original Tender Notice
https://gem.gov.in/ |
| Start Date | September 18, 2023 20:28 |
| End Date |
Expired
28/09/2023
Expired 1115 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Award of Contract & Bid Results
Technical Evaluation Results
| S.No. | Seller Name | Offered Item | Participated On | MSE/MII Status | Status |
|---|---|---|---|---|---|
| 1 | AYESHA ENTERPRISES | - | 28-09-2023 10:47:37 | MSE | Qualified |
| 2 | FIRE MAX INDIA | - | 28-09-2023 13:09:03 | MSE | Qualified |
| 3 | FIRESTOP SALES AND SERVICES | - | 28-09-2023 12:27:23 | N/A | Qualified |
| 4 | K C Marine Services | - | 28-09-2023 10:33:56 | N/A | Qualified |
| 5 | M/S PERFECT ENTERPRISES | - | 28-09-2023 13:36:51 | MSE | Qualified |
| 6 | NOTOFIRE PRIVATE LIMITED | - | 25-09-2023 16:21:06 | MSE | Qualified |
| 7 | ODISHA ELECTRICALS | - | 28-09-2023 13:41:58 | MSE | Qualified |
| 8 | TEXTEL TECHNOLOGIES PRIVATE LIMITED | - | 28-09-2023 12:27:22 | N/A | Qualified |
Financial Evaluation Results
| S.No. | Seller Name | Offered Item | Total Price | Rank |
|---|---|---|---|---|
| 1 | ODISHA ELECTRICALS( MSE Social Category:General ) | Item Categories : Control Panel,Smoke detector,Beam Smoke Detector,Manual Call point,Hooter cum strobe,24V 10 AMP pow | 397200.00 | L1 |
| 2 | AYESHA ENTERPRISES( MSE Social Category:General ) | Item Categories : Control Panel,Smoke detector,Beam Smoke Detector,Manual Call point,Hooter cum strobe,24V 10 AMP pow | 429790.00 | L2 |
| 3 | TEXTEL TECHNOLOGIES PRIVATE LIMITED | Item Categories : Control Panel,Smoke detector,Beam Smoke Detector,Manual Call point,Hooter cum strobe,24V 10 AMP pow | 495875.00 | L3 |
| 4 | M/S PERFECT ENTERPRISES( MSE Social Category:General ) | Item Categories : Control Panel,Smoke detector,Beam Smoke Detector,Manual Call point,Hooter cum strobe,24V 10 AMP pow | 501200.00 | L4 |
| 5 | FIRE MAX INDIA (MSE)( MSE Social Category:General ) | Item Categories : Control Panel,Smoke detector,Beam Smoke Detector,Manual Call point,Hooter cum strobe,24V 10 AMP pow | 558150.00 | L5 |
| 6 | NOTOFIRE PRIVATE LIMITED (MSE)( MSE Social Category:General ) | Item Categories : Control Panel,Smoke detector,Beam Smoke Detector,Manual Call point,Hooter cum strobe,24V 10 AMP pow | 613840.00 | L6 |
| 7 | FIRESTOP SALES AND SERVICES | Item Categories : Control Panel,Smoke detector,Beam Smoke Detector,Manual Call point,Hooter cum strobe,24V 10 AMP pow | 653019.00 | L7 |
| 8 | K C Marine Services | Item Categories : Control Panel,Smoke detector,Beam Smoke Detector,Manual Call point,Hooter cum strobe,24V 10 AMP pow | 2676165.00 | L8 |
Manual call point part no mcp2a-r470ff-01,communication module part no 116-bsl-310,ex interface unit, exiallc, 1 branch, 20 det (sep 24v) rev3
Manual call point part no mcp2a-r470ff-01,communication module part no 116-bsl-310,ex interface unit, exiallc, 1 branch, 20 det (sep 24v) rev3
Read moreSitc of 14 zone microprocessor based automatic fire detection main control panel,augmentation in the all existing afd system,sitc of photo electric smoke detector,sitc of ionization smoke detector,sitc of electropneumatic type dual action heat detector,sitc of electronic hooter or conventional hooter with lmt,sitc of response indicator for existing panel of visual indication,sitc of manual call point,supplying and fixing of 20mm size of steel conduit,supplying and fixing of 25mm size steel conduit size,supplying and drawing frls pvc insulated copper conductor, single core cable size 2x1.5sqmm,supplying and drawing frls pvc insulated copper conductor, single core cable size 3x1.5sqmm,supplying and drawing frls pvc insulated copper conductor, single core cable size 4x1.5sqmm,supplying and drawing frls pvc insulated copper conductor, single core cable size 5x1.5sqmm,supplying and drawing frls pvc insulated copper conductor, single core cable size 6x1.5sqmm,supplying and drawing frls pvc insulated copper conducto
Sitc of 14 zone microprocessor based automatic fire detection main control panel,augmentation in the all existing afd system,sitc of photo electric smoke detector,sitc of ionization smoke detector,sitc of electropneumatic type dual action heat detector,sitc of electronic hooter or conventional hooter with lmt,sitc of response indicator for existing panel of visual indication,sitc of manual call point,supplying and fixing of 20mm size of steel conduit,supplying and fixing of 25mm size steel conduit size,supplying and drawing frls pvc insulated copper conductor, single core cable size 2x1.5sqmm,supplying and drawing frls pvc insulated copper conductor, single core cable size 3x1.5sqmm,supplying and drawing frls pvc insulated copper conductor, single core cable size 4x1.5sqmm,supplying and drawing frls pvc insulated copper conductor, single core cable size 5x1.5sqmm,supplying and drawing frls pvc insulated copper conductor, single core cable size 6x1.5sqmm,supplying and drawing frls pvc insulated copper conducto
Read moreSupply installation, testing and commissioning of microprocessor based standalone fire alarm control panel.,supply installation, testing and commissioning of addressable smoke detector with inbuilt optical smoke sensors as per nfpa style 7 wiring complete with base and termination as required,supply installation, testing and commissioning of addressable manual call point as per nfpa style 7 wiring complete as required with backbox,supply, installation, testing and commissioning of sounder strobe,supply, installation, testing and commissioning of addressable single output module, suitable to drive conventional notification devices or other power required equipment,supply, installation, testing and commissioning of loop isolator module, protection facility for addressable loop,supply, installation, testing and commissioning of 2c x 1.5 sq mm frls armored cable
Supply installation, testing and commissioning of microprocessor based standalone fire alarm control panel.,supply installation, testing and commissioning of addressable smoke detector with inbuilt optical smoke sensors as per nfpa style 7 wiring complete with base and termination as required,supply installation, testing and commissioning of addressable manual call point as per nfpa style 7 wiring complete as required with backbox,supply, installation, testing and commissioning of sounder strobe,supply, installation, testing and commissioning of addressable single output module, suitable to drive conventional notification devices or other power required equipment,supply, installation, testing and commissioning of loop isolator module, protection facility for addressable loop,supply, installation, testing and commissioning of 2c x 1.5 sq mm frls armored cable
Read moreItem 1 - two loop addressable fire alarm control panel,item 2 - addressable manual call point with built in isolator,item 3 - addressable loop powered sounder,item 4 - addressable loop powered flasher,item 5 - addressable multi-criteria detector with built in isolator and accessories,item 6 - detector back box,item 7 - supply and laying of twisted pair 3 core, 2.5 sq mm power cable,item 8 - supply and laying of 2c x 1.5sq.mm, twisted pair,item 9 - supply and laying of gi conduit 20 mm dia 1.6mm,item 10 - supply and laying of standard 20 mm lsi approved casing and capping,item 11 - 25 mm corrugated flexible conduit,item 12 - supply and fixing of miniature circuit breaker
Item 1 - two loop addressable fire alarm control panel,item 2 - addressable manual call point with built in isolator,item 3 - addressable loop powered sounder,item 4 - addressable loop powered flasher,item 5 - addressable multi-criteria detector with built in isolator and accessories,item 6 - detector back box,item 7 - supply and laying of twisted pair 3 core, 2.5 sq mm power cable,item 8 - supply and laying of 2c x 1.5sq.mm, twisted pair,item 9 - supply and laying of gi conduit 20 mm dia 1.6mm,item 10 - supply and laying of standard 20 mm lsi approved casing and capping,item 11 - 25 mm corrugated flexible conduit,item 12 - supply and fixing of miniature circuit breaker
Read moreAddressable fire alarm panel,heat detector,smoke detector,manual call point,hooter cum strobe,exter
Read more
Addressable fire alarm panel,heat detector,smoke detector,manual call point,hooter cum strobe,exter
Read more
Multi detector,24v dc manual call point,fire alarm electronic hooter cum strobe,metal base back box
Read more
of your Industry type