Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Supply And Commissioning Of Igbt Based Constant Current /Constant Voltage Battery Charge /Discharge Panel (155 V 100 A) For Charging / Discharging Batteries (Unit Output Volt Amp 155 V 100 Amps Output Voltage Variation 40 155 V, Unit Output Current Variation 10 100 Amps ).
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106455821 |
|
Reference Number |
NJ245065A |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Guwahati |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/092024/106455821/viewNitPdf_4695071.pdf |
| Start Date | August 28, 2024 19:03 |
| End Date |
Expired
06/09/2024
Expired 770 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Programmable current transducer, input: 0-1aac, range: 0-1aac, output: 4-20 ma dc (dual output) , accu,multifunction meter for metering panels (with rs485modbus) , input: on site programmable-voltage - 10
Programmable current transducer, input: 0-1aac, range: 0-1aac, output: 4-20 ma dc (dual output) , accu,multifunction meter for metering panels (with rs485modbus) , input: on site programmable-voltage - 10
Read morePcb for auto functioning for 150 amps alind make cls panel suitable for 03 nos incoming supply source of 220 volt ac with voltage variation from 165 volt to 270 volt ac.
Pcb for auto functioning for 150 amps alind make cls panel suitable for 03 nos incoming supply source of 220 volt ac with voltage variation from 165 volt to 270 volt ac.
Read moreDigital type, three phase thyristor power regulator, model no. aspr 6000, capacity: 162 amps, loadin,reo frequency controller, reovib mfb 168, voltage(in) -110/240v & voltage(out) : 0-102/205v, current-6a
Digital type, three phase thyristor power regulator, model no. aspr 6000, capacity: 162 amps, loadin,reo frequency controller, reovib mfb 168, voltage(in) -110/240v & voltage(out) : 0-102/205v, current-6a
Read more24v starter battery charger for 500 kva dg set of eog power car conforming to rcf spec. no. edts - 106 (rev-0) am-1,2 & corr-1 / latest input voltage: 230 +/- 5 volts ac, output voltage: 27 volts dc, current rating: 50amps.
24v starter battery charger for 500 kva dg set of eog power car conforming to rcf spec. no. edts - 106 (rev-0) am-1,2 & corr-1 / latest input voltage: 230 +/- 5 volts ac, output voltage: 27 volts dc, current rating: 50amps.
Read moreOscilloscope8 channel 500 mhz bandwidth,> : 2 kv 100mhz differential voltage probes,optical isolated probe 200 mhz,dc to 100 mhz current probe and power supply
Oscilloscope8 channel 500 mhz bandwidth,> : 2 kv 100mhz differential voltage probes,optical isolated probe 200 mhz,dc to 100 mhz current probe and power supply
Read moreIndustrial heavy duty portable welding machine arc 250-amps with standard accessories electrode holder with earth & working clamp with 1.5 mtr cable and euro connectors, specification : voltage-230v, dimension375x155x232mm approx., current-250 a, body-steel and fiber, weight-approx 7 kg
Industrial heavy duty portable welding machine arc 250-amps with standard accessories electrode holder with earth & working clamp with 1.5 mtr cable and euro connectors, specification : voltage-230v, dimension375x155x232mm approx., current-250 a, body-steel and fiber, weight-approx 7 kg
Read moreDin type high voltage hrc fuse net 1 and net 2, rated current: 125 amps, rated voltage: 1000 v ac, breaking capacity: 80ka suitable for use in lhb eog/hog type ac coaches conforming to rdsos ltr. no. el/7.1.108/mssbc dtd. 17.09.2021. acceptable make : siba [2028003.125] / efen / eti [4182495] / siemens / eaton bussmann [125nh1lir-1000].
Din type high voltage hrc fuse net 1 and net 2, rated current: 125 amps, rated voltage: 1000 v ac, breaking capacity: 80ka suitable for use in lhb eog/hog type ac coaches conforming to rdsos ltr. no. el/7.1.108/mssbc dtd. 17.09.2021. acceptable make : siba [2028003.125] / efen / eti [4182495] / siemens / eaton bussmann [125nh1lir-1000].
Read moreAc high voltage breakdown tester,power: [ac high voltage breakdown tester,power: 230v ac, 50 hz voltage range: 0 to 5 kv ac leakage current range: 0 to 100 ma test voltage range settable by knob of variac. trip current settable by press to set switch and potentiometer on ma meter. metering: 3 1/2 digit digital kv meter, ma meter accuracy: kv: 2 percent of reading +/- 3 digit, ma: 1.5 percent +/- 2 digit resolution: 0.1kv, 0.1ma respectively programmable timer: range: 0 to 999 seconds indicat
Ac high voltage breakdown tester,power: [ac high voltage breakdown tester,power: 230v ac, 50 hz voltage range: 0 to 5 kv ac leakage current range: 0 to 100 ma test voltage range settable by knob of variac. trip current settable by press to set switch and potentiometer on ma meter. metering: 3 1/2 digit digital kv meter, ma meter accuracy: kv: 2 percent of reading +/- 3 digit, ma: 1.5 percent +/- 2 digit resolution: 0.1kv, 0.1ma respectively programmable timer: range: 0 to 999 seconds indicat
Read moreCurrent transducer input 0 to 5a,frequency transducer range 45 50 55,ac volt transducer 0 to 150v sn0659395452,ac volt transducer 0 to500kv sn0659395410,active p transducer 0 to 600mw sn0659395444,dc v transducer tra 430 input volt 0 10v dc,pf transducer 0.5lg-1-0.5ld sn0659395401,reactive p transducer190.52le-0-190.52la,reactive pwr transducer mvar 600 9 600,volt to current tran sducer input 0 to 60mv,current transducer,dual output 0 to 1a ac,8066 ac trnsdr 0 to 5a 4 to 20ma sn06593,cur tran input 0 to 1a output 4 to 20ma aux 220vdc,cur transdcr davr u55 1ph 2w input 110vac,volt transr input 0 to 50vdc aux 24vdc 2 output,mw tran model 8075 output 4 to 20ma rang 0 to 190,w tran aux 220vdc output 4 to 20 ma ct 3000 1,mw transr 0 to 1.797mw ctr2500 1 pt415 110v,voltage transducer dual output 0 5kv ac,v tran aux 240vac output 4 to 20 ma 0 to 25kv,3phase power factor trnd 8091 0.5le 1 0.5la,power transducer dual output 0 to 16mw,power transducer dual output 0 to 25 mw
Current transducer input 0 to 5a,frequency transducer range 45 50 55,ac volt transducer 0 to 150v sn0659395452,ac volt transducer 0 to500kv sn0659395410,active p transducer 0 to 600mw sn0659395444,dc v transducer tra 430 input volt 0 10v dc,pf transducer 0.5lg-1-0.5ld sn0659395401,reactive p transducer190.52le-0-190.52la,reactive pwr transducer mvar 600 9 600,volt to current tran sducer input 0 to 60mv,current transducer,dual output 0 to 1a ac,8066 ac trnsdr 0 to 5a 4 to 20ma sn06593,cur tran input 0 to 1a output 4 to 20ma aux 220vdc,cur transdcr davr u55 1ph 2w input 110vac,volt transr input 0 to 50vdc aux 24vdc 2 output,mw tran model 8075 output 4 to 20ma rang 0 to 190,w tran aux 220vdc output 4 to 20 ma ct 3000 1,mw transr 0 to 1.797mw ctr2500 1 pt415 110v,voltage transducer dual output 0 5kv ac,v tran aux 240vac output 4 to 20 ma 0 to 25kv,3phase power factor trnd 8091 0.5le 1 0.5la,power transducer dual output 0 to 16mw,power transducer dual output 0 to 25 mw
Read moreFeeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)
Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)
Read moreof your Industry type