Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Contactor For 60 Kva Transformer Suitable For Switch Board Cabinet Of Lhb Eog Ac Coaches..........
|
| Description |
For Complete Deion And Other Details, Please Refer To Tender
|
| Organisation | Ministry of Railways | Central Govt. Ministry/Department |
| Tender Id | 106424882 |
|
Reference Number |
68241645 |
| Tender Fee | 0 |
| EMD | 0 |
| Tender Value | - |
| Place | Jabalpur |
| Link |
View Original Tender Notice
https://www.ireps.gov.in/ireps/supply/pdfdocs/082024/106424882/viewNitPdf_4660337.pdf |
| Start Date | July 29, 2024 21:08 |
| End Date |
Expired
05/08/2024
Expired 800 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Landing door closing weight rope dead weight rope part no 511970065g01,smh318221 antistatic handrail brush handrail antistatic brush suitable for schindler make escalator dimensions head diameter 10mm handle length 36mm handle width 38mmthickness 2mm,emergency stop button m22 pv,lop230fuse 250v 2amp,key switch part no nea462553,schindler escalator ing key switch suitable for schindler make escalator,invk sensor step missing sensor for schindler make escalator,rkph phase monitoring relay suitable to schindler make escalator,comb light for schindler make escalator,signal led-s.gn-60-r directlon indicator red suitable for schindler make escalator,signal led s gn 60 g directlon indicator green suitable for schindler make escalator,limit switch tir 23 11z m20 suitable for schindler make escalator,flange bearing handrail shaft bearing 65 type 213,tension weight pulley
Landing door closing weight rope dead weight rope part no 511970065g01,smh318221 antistatic handrail brush handrail antistatic brush suitable for schindler make escalator dimensions head diameter 10mm handle length 36mm handle width 38mmthickness 2mm,emergency stop button m22 pv,lop230fuse 250v 2amp,key switch part no nea462553,schindler escalator ing key switch suitable for schindler make escalator,invk sensor step missing sensor for schindler make escalator,rkph phase monitoring relay suitable to schindler make escalator,comb light for schindler make escalator,signal led-s.gn-60-r directlon indicator red suitable for schindler make escalator,signal led s gn 60 g directlon indicator green suitable for schindler make escalator,limit switch tir 23 11z m20 suitable for schindler make escalator,flange bearing handrail shaft bearing 65 type 213,tension weight pulley
Read moreMs sheet 1.5mm,ms angle 50x50x06mm,ms channel mc 75x40,ms pipe diameter 50mm,gi sheet,contactor 3-f, 2 to 8a,forward-reverse switch - 16a,lamp 100w,contactor 1 - f 2 to 8a,rcc drill bit set,2 pin male female plug 6a,lamp 200w,lamp 60w,lamp 40w,fancy lamp holder,electronic component kit,pvc form board a4,indicator lamp switch type,rj45 connector,intermidiate switch,cable entry plate,transformer 230v-12v,paper-plastic capacitor,mica capacitor,electrolite capacitor,input output box with socket
Ms sheet 1.5mm,ms angle 50x50x06mm,ms channel mc 75x40,ms pipe diameter 50mm,gi sheet,contactor 3-f, 2 to 8a,forward-reverse switch - 16a,lamp 100w,contactor 1 - f 2 to 8a,rcc drill bit set,2 pin male female plug 6a,lamp 200w,lamp 60w,lamp 40w,fancy lamp holder,electronic component kit,pvc form board a4,indicator lamp switch type,rj45 connector,intermidiate switch,cable entry plate,transformer 230v-12v,paper-plastic capacitor,mica capacitor,electrolite capacitor,input output box with socket
Read moreAttending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Attending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Read moreAttending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Attending to break down calls,replacement lightening arrestor,replacement of faulty 11kv outdoor cable end termination,supplying laying acsr weasel conductor,replacement of 63a tpn switch fuse unit,replacement of 63a rewireable prcelin fuse set,replacement of 100a rewireable prcelin fuse set,replacement of pin insulators,replacement of disc insulators,dismantling the faulty transformer,refurbishment transformer 16 or 25 kva al wound,refurbishment transformer 63 kva capacity al wound,transportation charges for transformer,supplying laying of 3 into 50 sqmm ht ab cable,supplying laying of 4 into 25 sqmm lt ab cable,supplying making end termination for 4 core 25 sqmm lt ab cable
Read moreOil filter,fuel filter,air filter,fuel water separator assy,electrical fuel pump 12v pier burg type 53,servomotor with connector dtn04 3p,fuel solenoid valve 12 v,capacitor 60 mf,capacitor 50 uf,temperature sensor,temperature sensor,current transformer,oil pressure switch,resistor 100 k ohm 2 0w,terminator resistor,fuel non- valve,v belt,generator control system x control ggc s,remote control panel x control cp-g,communication cable fischer panda rj45 cat5e 15.0 m,circuit board external,semiconductor relay 42 660 vac 50,varistor type s 0v complete,sea water strainer
Oil filter,fuel filter,air filter,fuel water separator assy,electrical fuel pump 12v pier burg type 53,servomotor with connector dtn04 3p,fuel solenoid valve 12 v,capacitor 60 mf,capacitor 50 uf,temperature sensor,temperature sensor,current transformer,oil pressure switch,resistor 100 k ohm 2 0w,terminator resistor,fuel non- valve,v belt,generator control system x control ggc s,remote control panel x control cp-g,communication cable fischer panda rj45 cat5e 15.0 m,circuit board external,semiconductor relay 42 660 vac 50,varistor type s 0v complete,sea water strainer
Read moreMagnetic flux meter 0 to 500 tesla,tachometer analog type 10000 rpm,electric induction plate 1500 watt 240v,electric kettle 1500 watts 240v,ac ceiling fan and ac table fan 68 watt 230 v each,geyser storage type10 liter,mixture and grinder 750 w 240 v,washing machine semi automatic 5 kg,inverter with battery 1 kva with 12 v battery,wiring board 3 meter x 1 meter with 0 point 5 meter projection on the top,chain pulley block capacity with tripod stand 3 ton,electrical loadsof incandescent,rooftop mounting structure for 4 x 250 w solar panels mounting practice with tilt adjustment,electrical wiring and switch gear rack electrical control elements suitable f,protective relays and contactors rack suitable for practice of control,lead acid battery 12v 40ah,lead acid battery 12v 75ah,lead acid battery 12v 100 ah,halogen lamp with stand for llumination of solar panels in lab ac mains,multi meter analog,air impact wrench,lathe machine as per is 6893:1988
Magnetic flux meter 0 to 500 tesla,tachometer analog type 10000 rpm,electric induction plate 1500 watt 240v,electric kettle 1500 watts 240v,ac ceiling fan and ac table fan 68 watt 230 v each,geyser storage type10 liter,mixture and grinder 750 w 240 v,washing machine semi automatic 5 kg,inverter with battery 1 kva with 12 v battery,wiring board 3 meter x 1 meter with 0 point 5 meter projection on the top,chain pulley block capacity with tripod stand 3 ton,electrical loadsof incandescent,rooftop mounting structure for 4 x 250 w solar panels mounting practice with tilt adjustment,electrical wiring and switch gear rack electrical control elements suitable f,protective relays and contactors rack suitable for practice of control,lead acid battery 12v 40ah,lead acid battery 12v 75ah,lead acid battery 12v 100 ah,halogen lamp with stand for llumination of solar panels in lab ac mains,multi meter analog,air impact wrench,lathe machine as per is 6893:1988
Read moreKnife double blade,file flat 200,contactor and auxiliary,limit switch,cut out relay,over current relay,undervoltage relay,portable electric drill,load bank,brake test arrangement,earth plate copper plate,earth plate gi plate,earth electrode,rheostat 25 ohm,rheostat 300ohm,rheostat 1 ohm 10 amp,rheostat 10 ohm 5 amp,ohm meter series type,ohm meter shunt type,digital multimeter 3 1by2 digit,ac voltmeter mi,milli voltmeter center zero,ammeter mc analog 0 to 500ma,ammeter mc analog 0 to 5a,ammeter mc analog 0 to 25a,ac ammeter mi 0 to 1 a,ac ammeter mi 0 to 5 a,ac ammeter mi 0 to 25 a,kilo wattmeter analog,digital wattmeter 230v 1kw 50hz,ac energy metersingle phase,power factor meter,frequency meter 45 to 55hz,lux meter lcd,tmeter digital photo,tong tester,megger analog 500,3point dc er,4 point dc er,wheat stone bridge,single phase variable auto transformer,phase sequence indicator,growler 230,ac er registence type er,ac er dol er,ac er star delta er manual,ac er s
Knife double blade,file flat 200,contactor and auxiliary,limit switch,cut out relay,over current relay,undervoltage relay,portable electric drill,load bank,brake test arrangement,earth plate copper plate,earth plate gi plate,earth electrode,rheostat 25 ohm,rheostat 300ohm,rheostat 1 ohm 10 amp,rheostat 10 ohm 5 amp,ohm meter series type,ohm meter shunt type,digital multimeter 3 1by2 digit,ac voltmeter mi,milli voltmeter center zero,ammeter mc analog 0 to 500ma,ammeter mc analog 0 to 5a,ammeter mc analog 0 to 25a,ac ammeter mi 0 to 1 a,ac ammeter mi 0 to 5 a,ac ammeter mi 0 to 25 a,kilo wattmeter analog,digital wattmeter 230v 1kw 50hz,ac energy metersingle phase,power factor meter,frequency meter 45 to 55hz,lux meter lcd,tmeter digital photo,tong tester,megger analog 500,3point dc er,4 point dc er,wheat stone bridge,single phase variable auto transformer,phase sequence indicator,growler 230,ac er registence type er,ac er dol er,ac er star delta er manual,ac er s
Read moreN plus1 modular type 10 kva ups,static transfer switch with 24u rack with power strip,surge protection devices class b plus c or type 1 plus 2,surge protection devices class c or type,client station cpu with 55 inch or bigger led,client pc with 23 inch monitor along with other accessories,ups cms server each with 23 inch display,ups cms software for and client position,isolation transformer,fire resistant cable multi strand 03 core 6 sq mm,type b curve double pole mcbs 32 amp,type b curve double pole mcbs 63 amp,wall mounted polycarbonate enclosure with transparent door,metallic square channel minimum 3 inches wide,stainless steel flexible conduits minimum 1point5 inches wide,heavy duty copper lugs or thimbles as per power cables,metallic cable glands as per outer diameter of power cables,single core multistrand 6 sq mm copper cable,cost of installation integration testing and commissioning of complete system
N plus1 modular type 10 kva ups,static transfer switch with 24u rack with power strip,surge protection devices class b plus c or type 1 plus 2,surge protection devices class c or type,client station cpu with 55 inch or bigger led,client pc with 23 inch monitor along with other accessories,ups cms server each with 23 inch display,ups cms software for and client position,isolation transformer,fire resistant cable multi strand 03 core 6 sq mm,type b curve double pole mcbs 32 amp,type b curve double pole mcbs 63 amp,wall mounted polycarbonate enclosure with transparent door,metallic square channel minimum 3 inches wide,stainless steel flexible conduits minimum 1point5 inches wide,heavy duty copper lugs or thimbles as per power cables,metallic cable glands as per outer diameter of power cables,single core multistrand 6 sq mm copper cable,cost of installation integration testing and commissioning of complete system
Read moreBulb 100 watt,laser light pen hand-held, compact, pen-type laser pointer,bulb 60 watt,bulb 200 watt,power steering oil suitable for hydraulic power steering systems of automobiles and training vehicles,resistor box 0.25 watt,diode in 4001,thermister t 320,cement opc 43 grade or simillar,spark lighter hand-operated, push-button, type,wooden gitti rectangular or square block shape,bulb 40 watt,dc lamp 6v 100,ma,dc lamp 6v 300 ma,dc lamp 6v 150 ma,led driver 12 v,transistor 2n2222a,laser diode,resistor 1 kohm , 1 watt,dc lamp 6v 1w , 50ma,flexible conduit pipe 19 mm,solid state metal bridge rectifier 35a , 100v,padent switch 6a,bamboo wages approximately 100 or 150 mm lendth,0.22 mfd capacitor,0.33 mfd capacitor,chart hook for hanging training chart,carbon resistor 1 watt,wooden board 2x2 ft,220 ohm 2 w resistor,cotton tape roll minimum 10 m per roll,sunmica wooden board 24 by 12 inch,auto fuse 5 a,auto fuse 10 a,auto fuse 15 a,auto fuse 20 a,rj 45 connector,diode in 4007,wheel balacing weight 10 gram,whe
Bulb 100 watt,laser light pen hand-held, compact, pen-type laser pointer,bulb 60 watt,bulb 200 watt,power steering oil suitable for hydraulic power steering systems of automobiles and training vehicles,resistor box 0.25 watt,diode in 4001,thermister t 320,cement opc 43 grade or simillar,spark lighter hand-operated, push-button, type,wooden gitti rectangular or square block shape,bulb 40 watt,dc lamp 6v 100,ma,dc lamp 6v 300 ma,dc lamp 6v 150 ma,led driver 12 v,transistor 2n2222a,laser diode,resistor 1 kohm , 1 watt,dc lamp 6v 1w , 50ma,flexible conduit pipe 19 mm,solid state metal bridge rectifier 35a , 100v,padent switch 6a,bamboo wages approximately 100 or 150 mm lendth,0.22 mfd capacitor,0.33 mfd capacitor,chart hook for hanging training chart,carbon resistor 1 watt,wooden board 2x2 ft,220 ohm 2 w resistor,cotton tape roll minimum 10 m per roll,sunmica wooden board 24 by 12 inch,auto fuse 5 a,auto fuse 10 a,auto fuse 15 a,auto fuse 20 a,rj 45 connector,diode in 4007,wheel balacing weight 10 gram,whe
Read moreContactor for 60 kva transformer suitable for switch board cabinet of lhb eog ac coaches....
For complete deion and other details, please refer to tender
Read moreof your Industry type