Tender Details
Particulars | Details |
---|---|
Title |
" Kappa" Indoor Voltage Transformer, Ratio: 415/Rt3/110/Rt3/110/Rt3 V, Burden: 50/50 Va, Cl: 1.0/3 P,,
|
Description |
|
Organisation | NORTH EASTERN ELECTRIC POWER Corporation Limited | Ministry of Power |
Tender Id | GEM/2024/B/5586136 |
Reference Number |
|
Tender Fee | |
EMD | |
Tender Value | |
Place | |
Link | https://bidplus.gem.gov.in/all-bids |
Start Date | November 08, 2024 16:15 |
End Date |
30/11/2024 ( Expired 163 days ago ) Search Similar tenders? |
Join for More Relevant Opportunities |
50 va, 750/415 v ac, 3 phase, 3 wire star/star voltage measuring transformer for lhb ac power car, type-viii, as per rdso specification no: rdso/pe/spec/ac/0203-2020 (rev-0).asper rdso or rcf edts 103,rev-d,amdt-1,annexure-c note: as per bill of material was attached
For complete deion and other details, please refer to tender
Read morePower contactor 110 amp. 4 pole 415 v ac [power contactor 110 amp. 4 pole 415 v ac coil voltage 380-415 v ac 50 hz with 2 nc aux contact along with surge suppresor as per s.no.59 & item no. k-08, place of installation s1k43 of bill of material of rdso spec no. rdso/pe/spec/ac/0184-2015(rev.0). brands: l&t/siemens/schneider/abb only 1) the firm should submit authorized dealership certificate or proof of purchase from oem dealer and necessary test certificates along with materials for acceptance
For complete deion and other details, please refer to tender
Read moreE4943122 current transformer 01-sg4970649405-11kv indoor ct ratio 750/1, cl-ps, core-i, vk> = 300v,
Read more
Voltage measuring transformer 750/415 v, 3 phase, 100va, 3 wire, delta/delta 50 hz, class -1.0 with 2 a fuse in primary side and 2 a fuse in secondary side conforming to item no. 5 of bill of material rdso spec. no. rdso/pe/spec/tl/0195-2019 (rev.0) for switch board cabinet of hog compliant lslrd coaches. accepted makes as per bom.
For complete deion and other details, please refer to tender
Read moreOil cool arc weld transformer, voltage, input 415 vac+ /- 10, 50 hz, rating, current 80 to 400 a
Read more
Supply, testing and commissioning of two [supply, testing and commissioning of two phase primary current injection test kit , air/oil cooled ( transformer air cooled section and dimmerstat (variac) in oil cooled section ), input : 415 v , ac , 2ph, 50hz output: 0-25v at range of 0 to 5000amps with minimum resolution 1 amperes suitable for indoor use in maximum ambient temperature of 50 degree centigrade. above unit shall complete with 1.dimmerstat, dw transformer, output ammeter with ct and tr
For complete deion and other details, please refer to tender
Read morePotential transformer 33/36 kv as per is:3156:1992 latest, single phase with connector, 50 hz, ratio-33/36kv/v3/110//v3, class 1.0, outdoor - dual purpose voltage transformer - oil immersed, no. of secondary - 2, system earthing - isolated neutral system, e class insulation, copper winding, power frequency withstand voltage - kv (rms) - 70, lightning impulse withstand voltage - list 1 - kv (peak) ? 40, lightning impulse withstand voltage - list 2 - kv (peak- 170. rated output at a power factor
For complete deion and other details, please refer to tender
Read morePower contactor 110 amp. 4 pole 415 v ac [power contactor 110 amp. 4 pole 415 v ac coil voltage 380-415 v ac 50 hz with 2 nc aux contact along with surge suppresor as per s.no.59 & item no. k-08, place of installation s1k43 of bill of material of rdso spec no. rdso/pe/spec/ac/0184-2015(rev.0). brands: l&t/siemens/schneider/abb only 1) the firm should submit authorized dealership certificate or proof of purchase from oem dealer and necessary test certificates along with materials for acceptance
For complete deion and other details, please refer to tender
Read moreof your Industry type