Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Hrc Fuse Link (Din Type) 25 Amp, 415 /500 V Ac Breaking Cap 120k A, Size 000,Conf. To Rdso Specification No. Rdso/Pe/Spec/Ac/0184 2015 (Rev 1).
|
| Description |
Hrc Fuse Link (Din Type) 25 Amp, 415 /500 V Ac Breaking Cap 120k A, Size 000,Conf. To Rdso Specification No. Rdso/Pe/Spec/Ac/0184 2015 (Rev 1).
|
| Organisation | Ministry of Railways |
| Tender Id | Login to view |
|
Reference Number |
Login to view |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link | Login to view |
| Start Date | October 11, 2026 17:39 |
| End Date |
Open
06/11/2026
22 days left |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Mpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0)
Mpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0)
Read moreMpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).
Mpcb (motor protection circuit breaker), for ventilation fan unit 1& 2. thermal release range (rated current) 2.5-4 a, class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415 v ac, 1no+1nc auxiliary contact block, conforming to rdso spec. no. rdso/pe/spec/ac/0192-2018 (rev.1).
Read moreMpcb, current rating : 3-4 a, thermal release range: 2.5 - 4 .0 a, class: 10, breaking capacity: 50ka, pole: 3 p, voltage: 415 v ac, 1no+1nc auxiliary contact block. make: legrand (002807 = 002817), abb (ms116-4), hk1-11), schneider (gv2me08 = gvan11), l&t (st418960000 + sr419450000), siemens (3vu1340 - 0mj00 1no = 1nc:3rv1901-1a or 3vu9131-3aa00), c&s (tcms-32s-4 + tfx11), eaton (pkzm0-4 + nhi-11-pkz0) as per bill of material (bom) of rdsos specn. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as p
Mpcb, current rating : 3-4 a, thermal release range: 2.5 - 4 .0 a, class: 10, breaking capacity: 50ka, pole: 3 p, voltage: 415 v ac, 1no+1nc auxiliary contact block. make: legrand (002807 = 002817), abb (ms116-4), hk1-11), schneider (gv2me08 = gvan11), l&t (st418960000 + sr419450000), siemens (3vu1340 - 0mj00 1no = 1nc:3rv1901-1a or 3vu9131-3aa00), c&s (tcms-32s-4 + tfx11), eaton (pkzm0-4 + nhi-11-pkz0) as per bill of material (bom) of rdsos specn. no. rdso/pe/spec/ac/0184 - 2015 (rev. 0) as p
Read moreFeeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)
Feeder contactor, current rating 200 amps, voltage rating 750v ac main pole : 4 nos, aux contact : 2no +2nc, control voltage 380-415v ac with surge suppressor for net-1 & net-2 in sbc of double decker coaches confirming to item no 57& 58 of bom of rdso specification no rdso/pe/spec/0184-2015(rev-2)
Read moreAuto manual bypass rotary switch for air conditioning, current rating 16a, position: 3 (auto, manual, off), number of poles: 7, as per sr. no. 57 of bill of material (bom) of rdso specification no. rdso/pe/ spec/ac/0184-2015 (rev-1), suitable for use in switchboard cabinet of lhb type ac coaches. make: l&t / salzer, cat. no. 16a-d16-61031-b13-fhyr only. oem or authorized dealers with past proven performance to quote only
Auto manual bypass rotary switch for air conditioning, current rating 16a, position: 3 (auto, manual, off), number of poles: 7, as per sr. no. 57 of bill of material (bom) of rdso specification no. rdso/pe/ spec/ac/0184-2015 (rev-1), suitable for use in switchboard cabinet of lhb type ac coaches. make: l&t / salzer, cat. no. 16a-d16-61031-b13-fhyr only. oem or authorized dealers with past proven performance to quote only
Read more[hrc fuse link 25amp, 500v ac breaking cap 120ka, size nh000 conf. to is: 13703 and as per cat no. 3na3810 -7y of m/s siemens or equivalent. ]
For complete deion and other details, please refer to tender
Read morePt fuse (hrc) 2a gl 500v-120ka
For complete deion and other details, please refer to tender
Read moreCylindrical fuse 6a, 500v ac, 120ka breaking capacity
For complete deion and other details, please refer to tender
Read moreHrc fuse breaking capacity 120ka, 16 amps, 500v, din type 3na similar to siemens type no - 3na78050rc or similar to rdso approved
For complete deion and other details, please refer to tender
Read moreof your Industry type