Complete Re Insulation And Ht /Lt Stud Bush Replacement, Testing Through Nabl Repairing And Rewinding With Testing From Nabl Accredited Lab Of Transformer
|
| Description |
Complete Re Insulation And Ht /Lt Stud Bush Replacement, Testing Through Nabl Repairing And Rewinding With Testing From Nabl Accredited Lab Of Transformer Of
Township Under Rajrappa Area.
|
| Organisation | Central Coalfields Limited | Public Sector Undertakings |
| Tender Id | 2025_CCL_340364_1 |
|
Reference Number |
GM(R)/ SO(ENM)/Rjp/25-26/Et/55dt 28.07.25 |
| Tender Fee | 0 |
| EMD | 14600 |
| Tender Value | - |
| Place | RAJRAPPA |
| Link |
View Original Tender Notice
https://coalindiatenders.nic.in/nicgep/app?page=FrontEndTenderDetailsExternal&service=page&tnid=352847 |
| Start Date | July 29, 2025 23:30 |
| End Date |
Expired
07/08/2025
Expired 438 days ago |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Ut, mt and pt work on outsourcing basis by nabl accredited lab inside the factory at bhel
Ut, mt and pt work on outsourcing basis by nabl accredited lab inside the factory at bhel
Read moreCustom bid for services - service contract for micro test of production test coupons of bhel-hpvp, visakhapatnam as per ibr code at nabl accredited lab
Custom bid for services - service contract for micro test of production test coupons of bhel-hpvp, visakhapatnam as per ibr code at nabl accredited lab
Read moreTaking down of step up and down transformer 160kva after dismentling ht lt,gasket 6 mm thick superior quality on top cover plate,lt porcelain bushing with brass stud screwed with brass nuts bolts,ht 11 kv porcelain bushing with brass stud screwed with brass nuts,painting of transformer of rating 160 kva and voltage stabilizer with two coat,supply filling and top up with new transformer oil of electric strength,filtration dehydration of transformer oil of three phase servo voltage,rewinding of transformer 160 kva complete using appropriate size of copper,shifting of transformer from work shop to af stn including connecting,material and labour for arrange temporary power supply through comercial,trimming of tree branches to clear the ht lt oh lines girth span
Taking down of step up and down transformer 160kva after dismentling ht lt,gasket 6 mm thick superior quality on top cover plate,lt porcelain bushing with brass stud screwed with brass nuts bolts,ht 11 kv porcelain bushing with brass stud screwed with brass nuts,painting of transformer of rating 160 kva and voltage stabilizer with two coat,supply filling and top up with new transformer oil of electric strength,filtration dehydration of transformer oil of three phase servo voltage,rewinding of transformer 160 kva complete using appropriate size of copper,shifting of transformer from work shop to af stn including connecting,material and labour for arrange temporary power supply through comercial,trimming of tree branches to clear the ht lt oh lines girth span
Read moreCalibration services - electrical, electronics voltage, current, power (ac/dc), temperature, specific heat & humidity, calibration of insulation monitor device(imd) qty 02 nabl labs lab,calibration services - electrical, electronics voltage, current, power (ac/dc), temperature, specific heat & humidity, calibration of hygrometer qty 01 nabl labs lab,calibration services - electrical, electronics voltage, current, power (ac/dc), temperature, specific heat & humidity, calibration of protection meter qty 02 nabl labs lab
Calibration services - electrical, electronics voltage, current, power (ac/dc), temperature, specific heat & humidity, calibration of insulation monitor device(imd) qty 02 nabl labs lab,calibration services - electrical, electronics voltage, current, power (ac/dc), temperature, specific heat & humidity, calibration of hygrometer qty 01 nabl labs lab,calibration services - electrical, electronics voltage, current, power (ac/dc), temperature, specific heat & humidity, calibration of protection meter qty 02 nabl labs lab
Read moreCalibration services - mechanical, electrical, calibration of mat qty-01 each voltage, current, power (ac/dc), resistance, temperature nabl labs lab,calibration services - mechanical, electrical, calibration of earthing stick qty-01 each voltage, current, power (ac/dc), resistance, temperature nabl labs lab,calibration services - mechanical, electrical, calibration of article pg-1m qty-01 each voltage, current, power (ac/dc), resistance, temperature nabl labs lab,calibration services - mechanical, electrical, calibration of ruler qty-01 each voltage, current, power (ac/dc), resistance, temperature nabl labs lab,calibration services - mechanical, electrical, calibration of unified remote electrical single-needle pressure gauge qty-03 each voltage, current, power (ac/dc), resistance, temperature nabl labs lab,calibration services - mechanical, electrical, calibration of insulation check module mki 424311 312 qty-01 each voltage, current, power (ac/dc), resistance, temperature nabl labs lab,cal
Calibration services - mechanical, electrical, calibration of mat qty-01 each voltage, current, power (ac/dc), resistance, temperature nabl labs lab,calibration services - mechanical, electrical, calibration of earthing stick qty-01 each voltage, current, power (ac/dc), resistance, temperature nabl labs lab,calibration services - mechanical, electrical, calibration of article pg-1m qty-01 each voltage, current, power (ac/dc), resistance, temperature nabl labs lab,calibration services - mechanical, electrical, calibration of ruler qty-01 each voltage, current, power (ac/dc), resistance, temperature nabl labs lab,calibration services - mechanical, electrical, calibration of unified remote electrical single-needle pressure gauge qty-03 each voltage, current, power (ac/dc), resistance, temperature nabl labs lab,calibration services - mechanical, electrical, calibration of insulation check module mki 424311 312 qty-01 each voltage, current, power (ac/dc), resistance, temperature nabl labs lab,cal
Read moreOperation and maintenance of electrical systems/electrical installations - insulation of ht bus-bar along with insulating spray paint and testing of transformer oil at barc premises, trombay
Operation and maintenance of electrical systems/electrical installations - insulation of ht bus-bar along with insulating spray paint and testing of transformer oil at barc premises, trombay
Read moreTrolley based charge fire extinguisher o [trolley based charge fire extinguisher of dcp type suitable for abc class of fire having capacity of 50 kg, rechargeable type with isi mark conforming to is 16018 or latest with necessary test certificate from central govt/nabl/ilac accredited lab.]
Trolley based charge fire extinguisher o [trolley based charge fire extinguisher of dcp type suitable for abc class of fire having capacity of 50 kg, rechargeable type with isi mark conforming to is 16018 or latest with necessary test certificate from central govt/nabl/ilac accredited lab.]
Read moreSupply of required led lighting consumables ,insulation tapes and 11kv,1 core x 70 sq.mm ,aluminium xlpe cable,heat shrinkable straight through joint kits for essd and lt and ht lighting section of power house at slbhes
Supply of required led lighting consumables ,insulation tapes and 11kv,1 core x 70 sq.mm ,aluminium xlpe cable,heat shrinkable straight through joint kits for essd and lt and ht lighting section of power house at slbhes
Read moreOpen end torque wrench, click type trigg [open end torque wrench, click type triggers tactile and audible, accuracy + or - 3 percent , lock/unlock knob with ring for indication to operate about unlocked wrench, clockwise or anticlockwise operation, handle centre or calibration force point should be marked on handle, range-40nm - 200nm, with open end and ring spanner having size 18 and 19mm. with calibration certificate form nabl accredited lab]
Open end torque wrench, click type trigg [open end torque wrench, click type triggers tactile and audible, accuracy + or - 3 percent , lock/unlock knob with ring for indication to operate about unlocked wrench, clockwise or anticlockwise operation, handle centre or calibration force point should be marked on handle, range-40nm - 200nm, with open end and ring spanner having size 18 and 19mm. with calibration certificate form nabl accredited lab]
Read more3point3kv isolator on off earth reverse 400a part no kire,ammeter part no am,current transformer 60by5 15va part no 12060515,earth leakage relay 50 750 ma with time part no elm7lats,ht power fuse 3point3kv grade upto 100a part no hrc100,vacuum contactor 3point3kv part no bev006133,sensitive earth leakage relay 50 300ma w part no elm7stwpt,insulator support for ht pt fuse part no bs45,terminal bushing part no oba,aux contactor with coil part no boca2dn1229,busbar part no bbr300,brass cone and gland assembly part no bobcg,overload relay magnetic part no olr3,potential transformer 3point3kv 500va part no htptl1,ht bushing with stud 3point3 kv part no htta33
3point3kv isolator on off earth reverse 400a part no kire,ammeter part no am,current transformer 60by5 15va part no 12060515,earth leakage relay 50 750 ma with time part no elm7lats,ht power fuse 3point3kv grade upto 100a part no hrc100,vacuum contactor 3point3kv part no bev006133,sensitive earth leakage relay 50 300ma w part no elm7stwpt,insulator support for ht pt fuse part no bs45,terminal bushing part no oba,aux contactor with coil part no boca2dn1229,busbar part no bbr300,brass cone and gland assembly part no bobcg,overload relay magnetic part no olr3,potential transformer 3point3kv 500va part no htptl1,ht bushing with stud 3point3 kv part no htta33