Tender Details
Beyond this tender, use our platform to source any product, service, or solution.
Get direct quotes or register as a qualified provider.
| Particulars | Details |
|---|---|
| Title |
Sirolimus Eluting Coronary Stent System With Biodegradable Polymer On Cobalt Chromium Platform With Active Coating Per Set
|
| Description |
Sirolimus Eluting Coronary Stent System With Biodegradable Polymer On Cobalt Chromium Platform With Active Coating Per Set
|
| Organisation | Ministry of Railways |
| Tender Id | Login to view |
|
Reference Number |
Login to view |
| Tender Fee | - |
| EMD | - |
| Tender Value | - |
| Place | |
| Link | Login to view |
| Start Date | October 15, 2026 21:33 |
| End Date |
Open
27/10/2026
10 days left |
Tender Support
Get help with filing, GeM registration, documents, or relevant tender alerts.
Hq_med_sur_zrc_zonal rate contract for supply of ph:.(153045) sirolimus eluting stent cobalt - chromium stent with abluminal coating and specialised gradient coating (no polymer coating at joint & bends). bioresorbable polymer of plcl (poly lactic acid + poly caprolactone pcl) with degradation time of 3-4 months. low concentration of sirolimus (0.8ug/mm sq) should have bio-inspired open-cell. pmda approved
Hq_med_sur_zrc_zonal rate contract for supply of ph:.(153045) sirolimus eluting stent cobalt - chromium stent with abluminal coating and specialised gradient coating (no polymer coating at joint & bends). bioresorbable polymer of plcl (poly lactic acid + poly caprolactone pcl) with degradation time of 3-4 months. low concentration of sirolimus (0.8ug/mm sq) should have bio-inspired open-cell. pmda approved
Read moreHq_med_sur_ph:.(153049) drug eluting coronary stent system - platinum chromium hdvd - pvf everolimus drug eluting stent 2.25 mm to 4 mm all size
Hq_med_sur_ph:.(153049) drug eluting coronary stent system - platinum chromium hdvd - pvf everolimus drug eluting stent 2.25 mm to 4 mm all size
Read moreSmall arterial sheath,medium arterial sheath,large arterial sheath,2 way manifold,y connector,0.35 inch straight tipped ptfe wire regular length,0.35 inch ptfe j tipped wire exchange length,puncture needle radial artery,puncture needle femoral artery,polymer jacketed 0.35inch wire regular length,polymer jacketed 0.35inch wire exchange length,tavi valve,thrombus aspiration catheter,pigtail catheter,3 way manifold,transcatheter implantable pulmonary valve,inflation device,semicomplaint coronary balloons,noncomplaint coronary balloons,sirolimus eluting coronary stents size 4.5mm diameter or more,everolimus drug eluting stent,polymer free coronary stent
Small arterial sheath,medium arterial sheath,large arterial sheath,2 way manifold,y connector,0.35 inch straight tipped ptfe wire regular length,0.35 inch ptfe j tipped wire exchange length,puncture needle radial artery,puncture needle femoral artery,polymer jacketed 0.35inch wire regular length,polymer jacketed 0.35inch wire exchange length,tavi valve,thrombus aspiration catheter,pigtail catheter,3 way manifold,transcatheter implantable pulmonary valve,inflation device,semicomplaint coronary balloons,noncomplaint coronary balloons,sirolimus eluting coronary stents size 4.5mm diameter or more,everolimus drug eluting stent,polymer free coronary stent
Read moreVascular sheath radial artery 5 fr,vascular sheath radial artery 6 fr,vascular sheath femoral artery 6 fr,vascular sheath femoral artery 7 fr,vascular sheath femoral artery 8 fr,pressure monitoring line 200 cm maletofemale,high pressure line mf 120cm braided 1200 psi,manifold 2 port,unolock syringe 10 ml,temporary pacing wire 6 fr,puncture needle 18g,ptca guidewire hydrophilic 0.014 180 cm 2 mm distal tip,ptca guide wire standard,ptca guidewire hydrophilic,drug eluting stent everolimus cocr 100 micrometre usfda,drug eluting stent sirolimus cocr 100 micrometre usfda,drug eluting stent zotarolimus cocr 100 micrometre usfda,drug eluting stent biolimus a9 cocr 100 micrometre usfda,drug eluting stent everolimus ptcr 100 micrometre usfda,drug eluting stent sirolimus ptcr 100 micrometre usfda,drug eluting stent zotarolimus ptcr 100 micrometre usfda,drug eluting stent biolimus a9 ptcr 100 micrometre usfda,double lumen ptmc balloon dilatation catheter with complete accessories,mullins sheath 8 fr,guide wire 0.032 x 26
Vascular sheath radial artery 5 fr,vascular sheath radial artery 6 fr,vascular sheath femoral artery 6 fr,vascular sheath femoral artery 7 fr,vascular sheath femoral artery 8 fr,pressure monitoring line 200 cm maletofemale,high pressure line mf 120cm braided 1200 psi,manifold 2 port,unolock syringe 10 ml,temporary pacing wire 6 fr,puncture needle 18g,ptca guidewire hydrophilic 0.014 180 cm 2 mm distal tip,ptca guide wire standard,ptca guidewire hydrophilic,drug eluting stent everolimus cocr 100 micrometre usfda,drug eluting stent sirolimus cocr 100 micrometre usfda,drug eluting stent zotarolimus cocr 100 micrometre usfda,drug eluting stent biolimus a9 cocr 100 micrometre usfda,drug eluting stent everolimus ptcr 100 micrometre usfda,drug eluting stent sirolimus ptcr 100 micrometre usfda,drug eluting stent zotarolimus ptcr 100 micrometre usfda,drug eluting stent biolimus a9 ptcr 100 micrometre usfda,double lumen ptmc balloon dilatation catheter with complete accessories,mullins sheath 8 fr,guide wire 0.032 x 26
Read moreEverolimus drug eluting coronary stent on platinum chromium platform - bioabsorable with abluminal coating. additional connectors 4/5 in the proximal 2 segments. strut thickness 1.5 mm. available sizes 2.25 mm to 5.0 mm in diameter, 8.0 mm to 48 mm in length. 2 connector design throughout the body mecd >7.0 mm.
Everolimus drug eluting coronary stent on platinum chromium platform - bioabsorable with abluminal coating. additional connectors 4/5 in the proximal 2 segments. strut thickness 1.5 mm. available sizes 2.25 mm to 5.0 mm in diameter, 8.0 mm to 48 mm in length. 2 connector design throughout the body mecd >7.0 mm.
Read moreVascular suture mediated closure and repair system sterile with 3 point 0 mono filamen polypropylene suture 300 series stainless steel needles,non complaint ballon,holter patches disposable nc 1340 web cardio 7 days er proof wireless multiday holter patch sp7,everolimus eluting balloon mounted platinum chromium coronary stent system assorted size,flexible lead free radiation shield,high pressure 3 port manifold,dedicated kit angiography for radial,coronary angioplasty kit,zotarolimus eluting balloon expandable cobalt alloy coronary stent system with continuous sinusoidal design assorted size,terumo angiography guide wire 0 point 035 x 150 cm j tip,hp laser toner cartridge for hp laser 103a
Vascular suture mediated closure and repair system sterile with 3 point 0 mono filamen polypropylene suture 300 series stainless steel needles,non complaint ballon,holter patches disposable nc 1340 web cardio 7 days er proof wireless multiday holter patch sp7,everolimus eluting balloon mounted platinum chromium coronary stent system assorted size,flexible lead free radiation shield,high pressure 3 port manifold,dedicated kit angiography for radial,coronary angioplasty kit,zotarolimus eluting balloon expandable cobalt alloy coronary stent system with continuous sinusoidal design assorted size,terumo angiography guide wire 0 point 035 x 150 cm j tip,hp laser toner cartridge for hp laser 103a
Read moreCoronary stent- sirolimus eluting eluting des, cobalt chromium platform having biodegradable polyme
Read more
Coronary stent- sirolimus eluting eluting des, cobalt chromium platform having biodegradable polyme
Read more
of your Industry type