OXINIUM or TITANIUM NIOBIUM NITRIDE TOTAL KNEE REPLACEMENT SET, comprising of Femur made of Oxidized Zirconium/Titanium Niobium Nitride(TiNbN), Tibia-made of Titanium/Co-Cr, Poly highly cross linked. The product should have at least 5 years market standing & CE/USFDA Certified.[AI(2025-26) , Item Code No.S-61406, Sl No.1638]
Ministry of Railways | Central Govt. Ministry/Department · Kolkata
- EMD
- ₹0
- Tender fee
- ₹0
This tender closed on 28 Aug 2025.
Tender details
For complete deion and other details, please refer to tender
- Tender ID
- 106798817
- Reference number
- 22255516
- Organisation
- Ministry of Railways | Central Govt. Ministry/Department
- Location
- Kolkata
- Bids open
- 18 Aug 2025, 1:12 PM
- Bids close
- 28 Aug 2025, 1:30 PM
- Tender value
- –
- EMD
- ₹0
- Tender fee
- ₹0
Source: https://www.ireps.gov.in/ireps/supply/pdfdocs/082025/106798817/viewNitPdf_5081716.pdf
Bid on the next OXINIUM or TITANIUM NIOBIUM NITRIDE TOTAL tender
Most bids fail on paperwork. Before the next one opens, we'll check your eligibility and get your registrations, digital signature (DSC) and documents ready.
Similar tenders
-
For complete deion and other details, please refer to tender
Ministry of Railways | Central Govt. Ministry/Department · Kolkata Closed 13 Jan 2025
View tender -
High performance TKR prosthesis with titanium niobium nitride,Fixed bearing unicompartmental knee r
Department of Military Affairs | Ministry of Defence Closed 19 Aug 2024
View tender -
High performance TKR prosthesis with titanium niobium nitride,Fixed bearing unicompartmental knee r
Department of Military Affairs | Ministry of Defence Closed 31 Aug 2024
View tender -
INTERLOCKING NAIL TIBIA 9MM X 300MM WITH 4 LOCKING BOLTS. SPECIFICATIONS- 1 Should be made up of medical grade titanium 2 Nail should have anatomical anterior femoral bow 3 Nail should have four proximal locking and three distal locking options 4 Screws should be self-tapping 5 Company should provide the TIBIA nail and locking BOLTS SIX IN NUMBER of various length as per requirement 6 Implant should have jig for the distal locking screws 7 Firm should provide the technical assistance a
For complete deion and other details, please refer to tender
Ministry of Railways | Central Govt. Ministry/Department · Mumbai CST Closed 6 Nov 2024
View tender -
Tibial Nail Advanced (1 Nail 1 endcap 6 locking screws). Spec: Advanced Tibial nail which can used through Suprapatellar, Semi-extended Parapatellar and Infrapatellar approach for open & closed tibia fractures with inbuilt locking polymer into the nail for angular stability with 05 proximal and 04 distal locking options, most distal oblique locking screw hole offers choice of 300 medial/ lateral angulation made by Titanium Alloy
For complete deion and other details, please refer to tender
Ministry of Railways | Central Govt. Ministry/Department · Kolkata Closed 18 Sep 2025
View tender -
[ph.no.42963] tibia nail dia 8.5, 10.0 and 11.5 mm length 20-400 mm with 5 locking bolts 4.5 mm from 20-60 mm and 5.0 mm from 20-110 mm with one probe sterile packed nail and bolt made of titanium with semi extended zig. nail should have two proximal threaded holes and one hole with polyethylene bushing option to have 7 mm compression on table option. distal locking with computer based distal locking system
For complete deion and other details, please refer to tender
Ministry of Railways | Central Govt. Ministry/Department · Secunderabad Closed 8 Aug 2024
View tender -
[ph.no.42963] tibia nail dia 8.5, 10.0 and 11.5 mm length 20-400 mm with 5 locking bolts 4.5 mm from 20-60 mm and 5.0 mm from 20-110 mm with one probe sterile packed nail and bolt made of titanium with semi extended zig. nail should have two proximal threaded holes and one hole with polyethylene bushing option to have 7 mm compression on table option. distal locking with computer based distal locking system
For complete deion and other details, please refer to tender
Ministry of Railways | Central Govt. Ministry/Department · Secunderabad Closed 2 Sep 2024
View tender -
Adaptor sleeve for revision tkr specifications- 1 should be made up of cocr or medical grade titanium 2 should be compatible with existing knee revision system or tc3 3 should be available in various sizes for both femur and tibia 4 should be available in uncemented and cemented options 5 firm should be reputed with long term market standing. 6 compatible with revision system available in the hospital 7 company should supply all required instrumentations and implant along with t
For complete deion and other details, please refer to tender
Ministry of Railways | Central Govt. Ministry/Department · Mumbai CST Closed 16 Oct 2024
View tender -
Adaptor sleeve for revision tkr specifications- 1 should be made up of cocr or medical grade titanium 2 should be compatible with existing knee revision system or tc3 3 should be available in various sizes for both femur and tibia 4 should be available in uncemented and cemented options 5 firm should be reputed with long term market standing. 6 compatible with revision system available in the hospital 7 company should supply all required instrumentations and implant along with t
For complete deion and other details, please refer to tender
Ministry of Railways | Central Govt. Ministry/Department · Mumbai CST Closed 13 Nov 2024
View tender -
Adaptor sleeve for revision tkr specifications- 1 should be made up of cocr or medical grade titanium 2 should be compatible with existing knee revision system or tc3 3 should be available in various sizes for both femur and tibia 4 should be available in uncemented and cemented options 5 firm should be reputed with long term market standing. 6 compatible with revision system available in the hospital 7 company should supply all required instrumentations and implant along with t
For complete deion and other details, please refer to tender
Ministry of Railways | Central Govt. Ministry/Department · Mumbai CST Closed 17 Dec 2024
View tender